Built-In Installation
1. A minimum of 6” (15.2 cm) from the sides must be maintained from the side burners above the cooking surface to adjacent
vertical combustible construction. The unit is not to be located under overhead unprotected combustible construction.
2. It is desirable to allow at least 6” side clearance to non-combustible construction above the cooking surface for counter
space.
3. When determining a suitable location for the unit, take into account concerns such as exposure to wind, proximity to traffic
paths and keeping gas supply lines as short as possible. Locate only in a well-ventilated area. Never locate in a building,
garage, breezeway, shed or other such enclosed areas.
4. In a built-in construction where an LP/Propane tank is going to be used, there MUST be some type of support (braces, cut-
out, etc.) to prevent tank from moving within the installation. The support must also allow the LP/Propane tank to withstand
a horizontal tipping force equal to the weight of the tank without tipping over. The tank can not tip over or deflect more
than 1.00 inch when a 38 lb. horizontal force is applied to a 20 lb. LP/Propane tank.
IIM
MP
PO
OR
RT
TA
AN
NT
T:: G
Ga
ass ffiittttiin
ng
gss,, rre
eg
gu
ulla
atto
orr,, a
an
nd
d iin
nsstta
alllle
err ssu
up
pp
plliie
ed
d ssh
hu
utt--o
offff vva
allvve
e m
mu
usstt b
be
e e
ea
assiillyy a
acccce
essssiib
blle
e..
10-1
/4”
(26.0
cm
)
36”
(91.4
cm
)
27
-1/
2”
(69
.9 c
m)
14”
(35.6
cm
)
*So
lid b
otto
m
sup
por
t
Countertop typically
requires 1/2” wide by 1/2”
deep notch cutout on each
side of grill. This allows grill
Control Panel to sit back
properly in the cutout.
6” m
in
(15.2
cm
)
Gas inlet
location area
5”
(12.7
cm
)
5”
(12
.7
cm
)
1/2
”
(1.2
cm
)
1/
2”
(1.
2 c
m)
8
8
5
6
Bubbling bubbles in the soap solution indicates that a
leak is present.
Stop a leak by tightening the loose joint or by
replacing the faulty part with a replacement part
recommended by the manufacturer.
7
2
8
1
Do not attempt to repair the cylinder valve if it should
become damaged. The cylinder must be replaced.
If you are unable to stop a leak, shut off the gas
at the cylinder valve. Remove the cylinder from the grill.
Call an authorized gas
appliance service technician
or LP/Propane gas dealer.
Do not use the grill until
the leak is corrected.
1
2
9
After checking for leaks, push in and turn any control
knob to release the pressure in the hose and manifold.
Turn off the control knob.
Cutout Dimensions