Viking VGBQ410-3RE1* Скачать руководство пользователя страница 6

VGBQ410-3RE1*

T-Series/E-Series

Three-Burner All-Grill

VGBQ412-2RE1*

T-Series/E-Series

Two-Burner Grill

w/Side Burners

VGIQ410-3RT/E1*

T-Series /E-Series

Three-Burner All-Grill

(inc. TruSear™ Burner)

GAS

Fixed piping installations

• Check with local gas utility

company or with local codes
for instructions on installing
gas supply lines. All gas
connections should be made
by a competent technician and
in accordance with local codes
and or ordinances. In the
absence of codes, the
installation must comply with
the National Fuel Gas Code
ANSI Z223.1.

• An installer-supplied gas shut-

off valve must be installed in
an easily accessible location.
All installer-supplied parts
must conform to local codes.

• Must be isolated from the gas

supply piping system by
closing its individual manual
shut-off valve during any
pressure testing of that system
at test pressures equal to or
less than 1/2 psi (3.5 kPa).

Natural gas models

Water column pressure

o Operating pressure—4.0"

WCP

o Supply pressure of 6" – 14"

WCP

o If incoming pressure exceeds

14" WCP, a step-down
regulator is required.

Accepts standard residential
1/2” (1.3 cm) ID gas service
line; 1/2” (1.3 cm) NPT male
with 7/8” (2.2 cm) flare adapter.

o If using a Viking GSH12

flexible hose, remove the
1/2” (1.3 cm) flare adapter
and attach hose to the 7/8”
(2.2 cm) male flare on the
regulator assembly.

LP/propane models

Water column pressure

o Operating pressure—10” WCP
o Supply pressure of 11” – 14”

WCP (for fixed piping
installations)

o If incoming pressure exceeds

14” WCP, a step-down
regulator is required.

Accepts standard residential
1/2” (1.3 cm) ID gas service
line; 1/2” (1.3 cm) NPT male
with 3/8” (0.95) flare adapter.

LP/propane tank installations

Water column pressure

o Operating pressure—10”

WCP

Includes high-capacity
hose/regulator assembly for
connection to a standard 5-
gal./20-lb. (approx. 12”
diameter/18”H.) LP/propane
gas cylinder equipped with a
Type 1, QCC-1 connector

o The cylinder connection

device must be compatible
with the Type 1, QCC-1
connector on the outdoor
cooking appliance.

o The cylinder must be

provided with a shut-off
valve terminating in an
LP/propane gas supply
cylinder valve outlet
specified.

o The cylinder supply system

must be arranged for vapor
withdrawal and provided
with a listed OPD (overfilling
prevention device).

ELECTRICAL

T-Series models

o 9-volt DC battery for

electronic ignition

o 2’ (61.0 cm) power cord

supply cord with 3-prong
grounded plug attached to
rotisserie motor.

120 VAC/60 Hz

o Rotisserie motor max. amp

usage—6.0

E-Series models

o 3’ (91.4 cm) power cord

supply cord with 3-prong
grounded plug attached to
grill

120 VAC/60 Hz

o 120 VAC/60 Hz
o Grill max. amp usage

VGBQ/VGIQ410—2.2

VGBQ/VGIQ412—2.3

o 2’ (61.0 cm) power cord

supply cord with 3-prong
grounded plug attached to
rotisserie motor.

120 VAC/60 Hz

o Rotisserie motor max. amp

usage—6.0

PLUMBING

Not applicable

UTILITY

REQUIREMENTS

OUTDOOR—COOKING

41”W. Ultra-Premium T-Series/E-Series Gas Grill

P L A N N I N G A N D D E S I G N G U I D E

V I K I N G R A N G E . C O M

1 - 8 8 8 - V I K I N G 1

Installation Requirements

VGBQ410-3RE1

VGBQ412-2RE1

VGIQ410-3RT/E1

VGIQ412-2RT1

VGIQ411-2RE1

Burner rating

Standard SS grill burners (each)

25,000 BTU (7.3 kW) Nat./22,500 BTU (6.5 kW) LP (T-Series)

29,000 BTU (7.3 kW) Nat./28,000 BTU (6.5 kW) LP (E-Series)

Smoker burner (split standard)

12,500 BTU (3.7 kW) Nat./10,500 BTU (3.1 kW) LP

GourmetGlo™ rotisserie burner

15,000 BTU (4.4 kW) Nat./13,500 BTU (4.0 kW) LP

Side grill burners (each)

15,000 BTU (4.4 kW) Nat./13,500 BTU (4.0 kW) LP

TruSear infrared burner

30,000 BTU (8.8 kW) Nat./LP

30,000 BTU (8.8 kW) Nat./LP 30,000 BTU (8.8 kW) Nat./LP

R E V I S E D 8 / 1 8 / 0 9

© 2 0 0 9 V R C — INFORMATION SUBJECT TO CHANGE

VGIQ412-2RT1*

T-Series Two-Burner Grill

w/Side Burners

(inc. TruSear™ Burner)/

VGIQ411-2RE1*

E-Series Two-Burner Grill

(inc. TruSear™ Side Burner)

Содержание VGBQ410-3RE1*

Страница 1: ...sted to three different positions allowing use of additional accessory racks Rotisseries standard on all Ultra Premium models rotisserie system consists of a 15 000 BTU Gourmet Glo infrared rear burne...

Страница 2: ...ouble configuration 15 000 BTU side burners o Entirely stainless construction provides excellent durability o Removable stainless steel grate support with separately removable stainless steel burner b...

Страница 3: ...n Notes Accessories for important information including fuel conversion kits carts and side burners 41 3 16 104 6 cm 32 3 4 83 2 cm 41 3 16 104 6 cm 26 7 8 68 3 cm VGBQ410 3RE1 VGBQ412 2RE1 VGIQ410 3R...

Страница 4: ...place the grill where the exhaust is directed at a window less than 24 61 0 cm to combustible material or any surface that is difficult to clean Allow at least 6 side clearance to non combustible cons...

Страница 5: ...R E V I S E D 8 1 8 0 9 2 0 0 9 V R C INFORMATION SUBJECT TO CHANGE 10 1 4 26 0 cm 36 91 4 cm Access door opening 28 71 1 cm 40 1 4 102 2 cm 3 7 6 cm min Electrical connection for rotisserie motor pos...

Страница 6: ...tandard 5 gal 20 lb approx 12 diameter 18 H LP propane gas cylinder equipped with a Type 1 QCC 1 connector o The cylinder connection device must be compatible with the Type 1 QCC 1 connector on the ou...

Страница 7: ...Light fits all Ultra Premium Grills Heavy duty construction Anodized brushed aluminum handle and visor 12 volt 20 watt lamp with 8 electrical cord 22 flexible gooseneck with heat sealed vinyl protect...

Страница 8: ...r 41 W all grill 30 13 5 R E V I S E D 8 1 8 0 9 2 0 0 9 V R C INFORMATION SUBJECT TO CHANGE Model Description Approx ship wt lbs kg WR2TSS Warming rack for 41 W grill w side burners 5 2 3 WR3TSS Warm...

Отзывы: