Gas and Electrical Connection
GAS CONNECTION
Verify the type of gas supply to be used,
either natural or LP, and make sure the
marking on the grill rating plate agrees with
that of the supply. Never connect an
unregulated gas line to the appliance. An
installer supplied gas shut-off valve must be
installed in an easily accessible location. All
installer supplied parts must conform tolocal
codes, or in the absence of local codes, with
the National Electrical Code, ANSI/NFPA 70
and the National Fuel Code, ANSI Z223.1.
In Canada:
Installation must be in accordance
with the current CSA-B149.1, Natural Gas
Installation Code or CSA-B149.2, Propane
Installation Code and/or local codes. All pipe
sealants must be an approved type and
resistant to the actions of LP gas. Never use
pipe sealant on flare fittings. All gas
connections should be made by a competent
technician and in accordance with local codes
and or ordinances. In the absence of codes,
the installation must comply with the National
Fuel Gas Code ANSI Z223.1. The gas grill and
its individual shut-off valve must be
disconnected from the gas supply piping
system during any pressure testing of that
system at test pressures in excess of 1/2 PSIG
(3.5 kPa). The gas grill must be isolated from
the gas supply piping system by closing its
individual manual shut-off valve during any
pressure testing of that system at test
pressures equal to or less than 1/2 psi (3.5
kPa). Built-in installations must be plumbed
using a fixed/hard line if the unit is going to
be operated at a distance exceeding 3 feet
(0.91 meters) from the fuel supply per ANSI
Z21.24 CSA.
GAS CONVERSION
To convert a grill from natural to
LP/Propane or LP/Propane to natural, you
MUST use conversion kit sold seperately.
ELECTRICAL CONNECTION
22
WARNING
DANGER
CAUTION
FOR YOUR SAFETY
Conversions should only be performed by an
authorized service technician.
WARNING
ELECTRICAL SHOCK HAZARD
This appliance is equipped with a 3’
(91.4 cm) 3-prong power cord with a
grounding plug for your protection
against shock hazard and should be
plugged directly into a properly grounded
receptacle. Do not cut or remove the grounding
prong from this plug. This unit is not fused and
installer must install a GFI. Unit must be
grounded in accordance with local codes or with
the National Electrical Code ANSI/NFPA 70, or
the Canadian Electrical Code, CSA C22.1.
Ventilation for Built-In Installations
1. At least one ventilation opening shall be provided on the exposed, exterior side of the
enclosure located within 5 inches (127 mm) of the top of the enclosure and unobstructed.
The opening(s) shall have a total free area of not less than 1 in
2
/lb. (14.2 cm
2
/kg) of stored
fuel capacity.
2. At least one ventilation opening shall be provided on the exposed, exterior side of the
enclosure 1 inch (25.4 mm) or less from the floor level and shall have a total free area of not
less than 1/2 in
2
/lb. (7.1 cm
2
/kg) of stored fuel capacity. The upper edge shall be no more
than 5 inches (127 mm) above the floor level.
3. Every opening shall have a minimum dimension so as to permit the entrance of a 1/8 inch
(3.2 mm) rod.
21
Vents
Not less than
5.00 inches
from inside
bottom of
countertop.
Not less than
1.00 inch from
inside floor of
installation.
1.00 inch maximum
5.00 inch
maximum
No more than 5.00 inches above
the floor of the installation.
5.00 inch
maximum