background image

2

N

NO

OT

TE

E::    IIF

F  IIN

NS

ST

TA

ALLLLIIN

NG

G  H

HO

OO

OD

D  W

WIIT

TH

H

W

WA

AR

RM

MIIN

NG

G  S

SH

HE

ELLF

F  P

PA

AN

NE

ELL,,    IIN

NS

ST

TA

ALLLL

W

WA

AR

RM

MIIN

NG

G  S

SH

HE

ELLF

F  P

PA

AN

NE

ELL  F

FIIR

RS

ST

T..

IIM

MP

PO

OR

RT

TA

AN

NT

T  --  P

PLLE

EA

AS

SE

E  R

RE

EA

AD

D  A

AN

ND

D  F

FO

OLLLLO

OW

W

•Before beginning, please read these instructions
completely and carefully.
•Do not remove permanently affixed labels, warnings, or

plates from the product.  This may void the warranty.

•Please observe all local and national codes and

ordinances.  If no local codes are applicable, wire in
accordance with the National Electrical Code,
ANSI/NFPA 70-1990.

••C

Ch

he

ecckk  w

wiitth

h  aa  q

qu

uaalliiffiie

ed

d  aan

nd

d  ttrraaiin

ne

ed

d  iin

nssttaalllle

err  o

orr  llo

occaall

cco

od

de

ess  ffo

orr  m

maakke

eu

up

p  aaiirr  rre

eq

qu

uiirre

em

me

en

ntt,,  iiff  aan

nyy..

•T

Th

he

e  iin

nssttaalllle

err  ssh

ho

ou

ulld

d  lle

eaavve

e  tth

he

esse

e  iin

nssttrru

uccttiio

on

nss  w

wiitth

h  tth

he

e

cco

on

nssu

um

me

err  w

wh

ho

o  ssh

ho

ou

ulld

d  rre

ettaaiin

n  ffo

orr  llo

occaall  iin

nssp

pe

ecctto

orr’’ss  u

usse

e  aan

nd

d

ffo

orr  ffu

uttu

urre

e  rre

effe

erre

en

ncce

e..

This hood is for residential installation only and is not
designed for installation over a commercial product.
Make sure power is off at the main circuit breaker or fuse
box before making connections.  T

To

o  aavvo

oiid

d  rriisskk  o

off  ffiirre

e,,

e

elle

eccttrriicc  ssh

ho

occkk,,  o

orr  iin

njju

urryy  tto

o  p

pe

errsso

on

nss,,  ttu

urrn

n  o

offff  tth

he

e  e

elle

eccttrriicciittyy

tto

o  tth

he

e  h

ho

oo

od

d  ffrro

om

m  tth

he

e  p

po

ow

we

err  ssu

up

pp

pllyy  b

be

effo

orre

e  sse

errvviicciin

ng

g  o

orr

cclle

eaan

niin

ng

g..

Viking Range hoods are equipped with variable speed
controls for blowers. These units will not function with a
single
speed ventilator. All Viking Range ventilator kits are
designed specifically for use with Viking Range hoods.
Use of
any non-Viking Range ventilator kit will void the hood
warranty.

W

WA

AR

RN

NIIN

NG

G

T

TO

O  R

RE

ED

DU

UC

CE

E  T

TH

HE

E  R

RIIS

SK

K  O

OF

F  F

FIIR

RE

E,,  E

ELLE

EC

CT

TR

RIIC

CA

ALL  S

SH

HO

OC

CK

K,,

O

OR

R  IIN

NJJU

UR

RY

Y  T

TO

O  P

PE

ER

RS

SO

ON

NS

S,,  O

OB

BS

SE

ER

RV

VE

E  T

TH

HE

E  F

FO

OLLLLO

OW

WIIN

NG

G::

1.  Installation work and electrical wiring must be done by

qualified person(s) in accordance with all applicable
codes and standards, including fire-rated construction.

2.  Sufficient air is needed for proper combustion and

exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent back drafting.  Follow
the heating equipment manufacturer’s guideline and
safety standards such as those published by the
National Fire Protection Association (NFPA), and the
American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code
authorities.

3.  When cutting or drilling into wall or ceiling, do not

damage electrical wiring and other hidden utilities.

4.  Ducted fans must always be vented to the outdoors.
5.  W

WA

AR

RN

NIIN

NG

G!!::    To reduce the risk of fire, use only metal

ductwork.
6.  C

CA

AU

UT

TIIO

ON

N!!:: To reduce risk of fire and to properly

exhaust air, be sure to duct air outside.  Do not vent
exhaust air into spaces within walls or ceilings, or into
attics, crawl spaces, or garages.

C

CA

AU

UT

TIIO

ON

N

For general ventilating use only.  Do not use

to exhaust hazardous or explosive materials

and vapors.

W

WA

AR

RN

NIIN

NG

G

TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK,
OR INJURY TO PERSONS, RANGEHOODS MUST BE
INSTALLED WITH THE VENTILATORS THAT ARE
SPECIFIED ON THEIR CARTON INDICATING
SUITABILITY WITH THIS MODEL.  OTHER VENTILATORS
CANNOT BE SUBSTITUTED.

W

WA

AR

RN

NIIN

NG

G

T

TO

O  R

RE

ED

DU

UC

CE

E  T

TH

HE

E  R

RIIS

SK

K  O

OF

F  A

A  R

RA

AN

NG

GE

ET

TO

OP

P  G

GR

RE

EA

AS

SE

E

F

FIIR

RE

E::

1.  Never leave surface units unattended at high

setting.  Boilovers cause smoking and greasy

spillovers that may ignite.  Heat oils slowly on

low or medium settings.

2.  Always turn hoon ON when cooking at high

heat or when cooking flaming foods.

3.  Clean ventilating fans frequently.  Grease should

not be allowed to accumulate on fan or filter.

4.  Use proper pan size.  Always use cookware

appropriate for the size of the surface element.

Содержание VEV900

Страница 1: ...Viking Installation Guide Designer Series Built In 18 H Hoods Viking Range Corporation 111 Front Street Greenwood Mississippi 38930 USA ...

Страница 2: ...e of any non Viking Range ventilator kit will void the hood warranty W WA AR RN NI IN NG G T TO O R RE ED DU UC CE E T TH HE E R RI IS SK K O OF F F FI IR RE E E EL LE EC CT TR RI IC CA AL L S SH HO OC CK K O OR R I IN NJ JU UR RY Y T TO O P PE ER RS SO ON NS S O OB BS SE ER RV VE E T TH HE E F FO OL LL LO OW WI IN NG G 1 Installation work and electrical wiring must be done by qualified person s i...

Страница 3: ...T TR RE EM ME EL LY Y I IM MP PO OR RT TA AN NT T T TO O E EN NS SU UR RE E M MA AX XI IM MU UM M P PE ER RF FO OR RM MA AN NC CE E F FR RO OM M A AN NY Y V VE EN NT TI IL LA AT TI IO ON N P PR RO OD DU UC CT T 1 All CFMs stated are based on tests at 1 static pressure without applying static pressure CFM would be greatly overstated 2 Duct run length is for general reference only for longer duct ru...

Страница 4: ...ood being 66 167 6 cm to 72 182 9 cm above the floor For best performance it is recommended that the bottom of the hood be 30 76 2 cm to 33 83 8 cm above the countertop These dimensions provide for safe and efficient operation of the hood C Cl le ea ar ra an nc ce e D Di im me en ns si io on ns s 18 45 7 cm 30 76 2 cm Min 36 91 4 cm Max 36 91 4 cm C Co ou un nt te er rt to op p ...

Страница 5: ...the wood strip Secure the hood to strip with mounting screws provided Make sure that the wood strip mounting screws are driven into the framing and not just the drywall Use additional mounting screws and wall anchors if necessary in the other holes N NO OT TE E B BE EC CA AU US SE E O OF F T TH HE E W WE EI IG GH HT T O OF F T TH HE E H HO OO OD D M MA AK KE E S SU UR RE E T TH HA AT T T TH HE E W...

Страница 6: ...ake all joints secure and air tight In some installations it is easier to attach transition to plate before attaching plate to hood 3 Remove wire box cover Remove a knockout from the wiring box Feed 6 of power cable through opening and attach cable to wiring in wiring box with appropriate connector W WA AR RN NI IN NG G MAKE SURE ELECTRICAL SUPPLY IS OFF 4 Wire black to black white to white and gr...

Страница 7: ...CFM Blower Rough in Plate Studs Barrel Nuts Top of Hood Wingnut Remove rear filter support before installing blower After installation is complete reinstall the rear filter support V VI IV V1 12 20 00 0 I In nt te er ri io or r P Po ow we er r V Ve en nt ti il la at to or r K Ki it t 1 12 20 00 0 C CF FM M also see instructions supplied with ventilator kit 1 Make sure barrel nuts and wing nut are ...

Страница 8: ...r to installation location 3 Remove wiring box cover Remove knockouts from the wiring box Feed 6 of power cable through the openings and attach cables to wiring box with appropriate connectors 4 Wire black to black white to white and green or bare wire beneath green ground screw Replace wiring box cover 5 Attach rough in plate to the studs at the inside top of hood with 4 10 24 nuts provided 6 Con...

Страница 9: ... away from prevailing winds 8 Remove roofing nails from the upper two thirds of the shingles around the cutout area Carefully lift the shingles to allow the back flashing sheet on the blower housing to fit under them 9 Center the blower ring in the 11 27 9 cm diameter hole making sure that the 11 4 3 2 cm diameter electrical wiring hold aligns with the hole in the wiring box 10 Attach the blower t...

Страница 10: ...housing along the outer edge 8 Center the blower ring in the 11 27 9 cm diameter hole making sure that the 11 4 3 2 cm diameter electrical wiring hole aligns with the hole in the wiring box 9 Attach blower to the wall with the six screws provided It is recommended that the screws be located inside the blower housing All six holes in the back panel must be filled or any moisture that may get inside...

Страница 11: ...iling winds 8 Remove roofing nails from the shingles around the top and sides of the cutout area only Carefully lift the shingles to allow the back flashing sheet on the blower housing to fit under them 9 Center the blower ring in the 11 27 9 cm diameter hole making sure that the 1 3 2 cm diameter electrical wiring hold aligns with the hole in the wiring box 10 Attach the blower to the roof with t...

Страница 12: ... diameter electrical wiring hole aligns with the hole in the wiring box 9 Attach blower to the wall with the six screws provided All six holes in the back panel must be filled or any moisture that may get inside the housing could leak into the house 10 Using a good grade of caulk seal all around the mounting screw heads 11 Bring electrical wiring through the hole in the wiring box and secure it ac...

Страница 13: ...241 2 62 2 cm 43 4 12 1 cm 14 35 6 cm 243 4 62 9 cm 151 2 39 4 cm 281 4 71 8 cm V VE EV V9 90 00 0 D DE EV V1 12 20 00 0 D DE EV V1 15 50 00 0 22 1 8 56 2 cm B B 10 1 8 25 7 cm A A 29 1 2 74 9 cm 10 25 4 cm Dia Opening for wiring Flashing Flashing Opening for wiring 3 1 2 8 9 cm 6 1 4 15 9 cm 5 12 7 cm 3 7 6 cm 14 13 16 37 6 cm 11 13 16 30 0 cm A B DEV1200 18 22 45 7 cm 55 9 cm DEV1500 21 25 53 3 ...

Страница 14: ...1 12 20 00 0 O On nl ly y B B 8 1 4 20 9 cm 5 15 16 15 1 cm 3 7 6 cm 6 7 16 16 4 cm 2 1 2 6 4 cm A A 3 30 0 W W 3 36 6 W W 4 42 2 W W E EX XT TE ER RN NA AL L P PO OW WE ER R V VE EV V9 90 00 0 o or r V VE EV V1 12 20 00 0 3 30 0 W W 3 36 6 W W 4 42 2 W W I IN NT TE ER RN NA AL L P PO OW WE ER R V VI IV V3 30 00 0 V VI IV V6 60 00 0 o or r V VI IV V1 12 20 00 0 24 61 0 cm 4 5 8 11 7 cm 18 3 4 47 6...

Страница 15: ... dia cutout 120 V 4 48 8 W W E EX XT TE ER RN NA AL L P PO OW WE ER R V VE EV V1 12 20 00 0 o or r V VE EV V1 15 50 00 0 4 48 8 W W I IN NT TE ER RN NA AL L P PO OW WE ER R V VI IV V1 12 20 00 0 47 7 8 121 6 cm 23 15 16 60 8 cm W WI IR RI IN NG G D DI IA AG GR RA AM M D DE ES SI IG GN NE ER R S SE ER RI IE ES S B BU UI IL LT T I IN N H HO OO OD DS S REFER ONLY TO FEATURES EQUIPPED WITH THIS UNIT ...

Страница 16: ...20040L PS1005VR VIKING RANGE CORPORATION 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com ...

Отзывы: