WARNING

TIP OVER HAZARD

Appliance is top heavy
and tips easily when
not completely
installed. Keep doors
closed until appliance
is completely installed
and secured per installation instructions.

Use two or more people to move and
install appliance. Failure to do so can
result in death or serious injury.

WARNING

ELECTRICAL SHOCK 
HAZARD

Disconnect power or turn 
power disconnect switch to 
OFF position before removing 
top grille. Failure to do so can 
result in death or electrical shock.

Most of the unit’s weight is at the top. Extra care is needed when moving the unit to prevent
tipping. Use cardboard shipping material or plywood under unit until it is installed in the 
operating position to protect floor surface.

A GFI 

shall be used if required by NFPA-70 (National Electric Code), federal/state/local laws, or

local ordinances.
• The required use of a GFI is normally related to the location of a receptacle with respect to

any significant sources of water or moisture.

• Viking Range Corporation will NOT warranty any problems resulting from GFI outlets which

are not installed properly or do not meet the requirements below.

If the use of a GFI is required, it should be:
• Of the receptacle type (breaker type or portable type NOT recommended)
• Used with permanent wiring only (temporary or portable wiring NOT recommended)
• On a dedicated circuit (no other receptacles, switches or loads in the circuit)
• Connected to a standard breaker of appropriate size (GFI breaker of the same size NOT

recommended)

• Rated for Class A (5 mA +/- 1 mA trip current) as per UL 943 standard
• In good condition and free from any loose-fitting gaskets (if applicable in outdoor situations)
• Protected from moisture (water, steam, high humidity) as much as reasonably possible

IMPORTANT–Please Read and Follow!

Содержание VCWB301

Страница 1: ...Installation Built in Full Height Wine Cellar VCWB301 ...

Страница 2: ...___ 14 Custom Side Panel Dimensions w fush mount trim ____________________________________ 15 General Information_________________________________________________________________16 Unpacking Moving________________________________________________________________17 Home Security System Connection____________________________________________________18 Securing Your Wine Cellar ________________________...

Страница 3: ...ely 1200 lbs 540 kg Provide a properly grounded electrical outlet Assure that location will permit appliance doors to open 90 minimum Your safety and the safety of others is very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to hazards that can kill or hu...

Страница 4: ...de federal state local laws or local ordinances The required use of a GFI is normally related to the location of a receptacle with respect to any significant sources of water or moisture Viking Range Corporation will NOT warranty any problems resulting from GFI outlets which are not installed properly or do not meet the requirements below If the use of a GFI is required it should be Of the recepta...

Страница 5: ...cm min to 84 1 16 213 5 cm max 29 73 7cm 70 177 5 cm 9 5 16 23 6 cm 22 3 16 56 4 cm Standard Mount 23 13 16 60 5 cm Flush Mount 24 1 32 61 0 cm 30 76 2 cm 27 68 6 cm NOTE Flush Mount Trim PBIRFTKSS is purchased separately Dimensions ...

Страница 6: ... handle bracket 27 68 6 cm 23 13 16 60 5 cm To front of door 24 1 32 61 0 cm To end of handle bracket 27 68 6 cm Cutout width 29 5 8 75 2 cm Cutout height 82 7 8 210 5 cm min to 84 1 16 213 5 cm max Cutout depth 24 61 0 cm min Electrical requirements 127 volt 60 Hz 15 amp dedicated circuit 3 wire cord with grounded 3 prong plug attached to product Maximum amp usage 2 3 amps Overall capacity 150 bo...

Страница 7: ...4 187 3 cm 4 10 2 cm 8 1 4 20 9 cm 3 1 2 8 9 cm 1 1 2 1 1 2 3 8 cm 3 8 cm 1 1 2 3 8 cm Custom Panel models fit flush in 25 63 5 cm deep cabinet openings They can be installed in standard 24 61 0 cm deep openings The door faces and top grille will protrude 3 4 1 9 cm into the room 2 x 4 Mounting Board 1 1 2 3 8 cm x 3 1 2 8 9 cm Attached to anti tip mounting bracket Note If unit is installed deeper...

Страница 8: ...penings The door face protrudes 2 1 16 5 2 cm from the cabinet face The handle protrudes an additional 2 1 2 6 4 cm into the room Door Wall 1 13 16 4 6 cm 3 4 1 9 cm full end panel 24 61 0 cm standard cabinet depth 5 16 0 8 cm 2 1 16 5 2 cm offset TOP VIEW Cabinet Information ...

Страница 9: ...9 cm full end panel 24 61 0 cm standard cabinet depth 2 1 16 5 2 cm offset Professional models fit semi flush in standard 24 61 0 cm deep cabinet openings The door face protrudes 2 1 16 5 2 cm from the cabinet face The handle protrudes an additional 2 1 2 6 4 cm into the room TOP VIEW Cabinet Information ...

Страница 10: ...Wall Partial overlay cabinet door 1 13 16 4 6 cm space if 24 61 0 cm standard cabinet depth is used 3 4 1 9 cm full end panel 24 61 0 cm standard cabinet depth 2 1 16 5 2 cm offset TOP VIEW Cabinet Information ...

Страница 11: ...t Trim fit flush in standard 24 61 0 cm deep cabinet openings with no protrusion into the room except 2 1 2 6 3 cm handle depth Door Flush Wall 25 63 5 cm 1 2 5 cm 3 4 1 9 cm full end panel TOP VIEW Cabinet Information with Flush Mount Trim ...

Страница 12: ...penings with no protrusion into the room except 2 1 2 6 3 cm handle depth Door Flush Countertop depth Wall 1 2 5 cm space if 25 63 5 cm cabinet depth is used 24 61 0 cm standard cabinet depth Cabinet front 25 63 5 cm 3 4 1 9 cm full end panel TOP VIEW Cabinet Information with Flush Mount Trim ...

Страница 13: ...ne cellar and cabinet door flush Wall 24 3 4 62 9 cm Cabinet door 3 4 1 9 cm space if 24 61 0 cm standard cabinet depth is used 24 61 0 cm standard cabinet depth TOP VIEW Cabinet Information with Flush Mount Trim ...

Страница 14: ...m Optional kickplate Notch dimensions determined by cabinets 82 7 8 210 5 cm min to 84 1 16 213 5 cm max 22 3 16 56 4 cm 82 7 8 210 5 cm min to 84 1 16 213 5 cm max 6 15 2 cm 22 3 8 57 0 cm Depending on how high leveling feet are raised and cabinet enclosure height TOP VIEW Custom Side Panel Dimensions Standard Mount ...

Страница 15: ...to 84 1 16 213 5 cm max 82 7 8 210 5 cm min to 84 1 16 213 5 cm max Depending on how high leveling feet are raised and cabinet enclosure height NOTE Adding a 3 4 1 9 cm side panel adds an additional 3 4 1 9 cm to the overall width of the product for each side panel used Requires side panel hardware kit Kit model number SPHKDS TOP VIEW Custom Side Panel Dimensions with Flush Mount Trim ...

Страница 16: ...nces 127 volt 60 Hz 15 amp fused electrical supply is required It is required that a separate circuit serving only this appliance be provided This appliance is equipped with a power supply cord having a 3 prong grounding plug To minimize possible shock hazard the cord must be plugged into a mating 3 prong grounding type wall receptacle Do not use an extension cord If codes permit a separate ground...

Страница 17: ...xterior packaging Save cardboard shipping material to protect floor surface when installing unit Remove anti tip boards and kickplate from rear of unit Moving Unit Remove shipping brackets from skid by removing four bolts two on each side with a 1 2 deep well socket wrench and a pair of pliers NOTE Tilting unit is not required to remove shipping brackets Slip appliance dolly between unit and skid ...

Страница 18: ...inet 2 per side 2 Remove the grille louver assembly to access the black safety grille 3 Turn power off 4 Remove the four screws that attach the top grille assembly to the mounting brackets 5 Remove the 3 screws at the right side of the unit that attach the safety grille to the compartment cover 6 Choose the desired switching position and connect according to alarm system requirements 7 Replace the...

Страница 19: ... it to wall studs using eight of the provided wood screws and L brackets Make sure screws extend a minimum of 1 2 5 cm into each of the two wall studs The wood block must extend a minimum of 3 7 6 cm over the unit To secure the wine cellar raise unit until compartment is firmly seated under the anti tip boards WARNING ELECTRICAL SHOCK HAZARD Disconnect power at breaker or turn power disconnect swi...

Страница 20: ... off the rollers adjust to desired height and level wine cellar by using a 5 16 hex head wrench Refer to Figure at the right a To raise lower right side rear rotate the right side rear hex rod b To raise lower the left side rear rotate the left side rear hex rod c To raise lower the right side front rotate the right side front hex rod d To raise lower the left side front rotate the left side front...

Страница 21: ... holes in the bottom panel should line up with the slots in the top panel 2 Position the kickplate assembly along the front edge of the wine cellar 3 Align the holes on both ends of the top louvered panel with the holes in the base of the wine cellar 4 Attach the kickplate to the wine cellar on each side with the two black phillips head screws provided 5 Adjust the bottom solid panel to the desire...

Страница 22: ...e pin to the utmost rear stop hole HINGE ADJUSTMENT 1 Using a 3 16 Allen wrench remove the door stop pin located in bottom hinge 2 Using the height adjustment shim as a wrenching device rotate the height adjustment bushing counterclockwise to raise or clockwise to lower the location of the door 3 When proper adjustment is reached align shim with door stop pin holes and replace door stop pin Firmly...

Страница 23: ...treet Greenwood Mississippi 38930 USA The serial number and model number for your wine cellar are located on the right wall in the bottom zone Record the information indicated below You will need it if service is ever required Model number ____________________________________________________________________________________ Serial number _____________________________________________________________...

Страница 24: ...Viking Range LLC 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 845 4641 or visit the Viking Web site at vikingrange com F20904D EN 040116 UL C UL ...

Отзывы: