VCSO210SS
15
End
NO
NO
NO
NO
NO
NO
NO
YES
YES
NO
YES
YES
YES
YES
YES
YES
NO
YES
Unplug the water tank, power on the
oven, put oven into test mode 00.
Fill the tank with water to the water
level 2 and plug tank into oven.
Did water transfer from tank to Water
Level unit?
Are there disconnection and short circuit in the water level sensor
connectors, connecting between the board and the sensor section?
Are there disconnection and short circuit in the water level sensor
connectors, connecting between the board and the sensor section?
Measure resistance of a set of the three (3) water level sensors with the
sensor connecting connector pulled out of the board.
Measure resistance of a set of the three (3) water level
sensors with the sensor connecting connector pulled out of
the board. (with the water tank filled with water)
Is the measured resistance value of
the set infinite?
Is the measured resistance value
of the set infinite?
Replace the control board or
the display board.
Replace the control board or the display board.
Check/replace the connection between the tank and the
Water Level unit.
Do the H-side and L-side water level sensors
indicate 01 or more in the test mode?
Is ion-changed or pure water being used?
Use common tap water.
After confirming that the water level sensor wiring of
the water tank is OK, replace the Water Level unit.
After confirming that the water level sensor wiring of the water tank is OK,
replace the Water Level unit.
Is the oven in the following conditions?
Test mode: 00 (see [9] TEST MODE page 21,22)
H-side water level sensor: 00 h
L-side water level sensor: 00 h
Is the unit in the following conditions?
Test mode: 00 (see [9] TEST MODE page 21,22)
H-side water level sensor: 80 (h) or more
L-side water level sensor: 80 (h) or more
Repair connector.
Repair connector.
If there is water touching/ covering the
three water level sensors it is NOT infinite.
You get anywhere from a few M ohms to a
few hundreds of K ohms.
NOTE:
1. How to check water supply performance
1) Check of water level sensor performance
[7] How to check in the event of an error
HOW TO SET THE TEST MODE
s
k
r
a
m
e
R
g
n
i
m
it
k
c
e
h
C
n
o
it
i
d
n
o
C
n
o
it
p
i
r
c
s
e
D
n
o
it
a
c
i
d
n
i
r
o
r
r
E
EE01
Oven thermistor fail-
ure
Short circuit
Open
Break/short-circuit
of thermistor
As soon as heating starts
Any time during heating
AH sensor failure
Break/short-circuit
of AH sensor
After 16~32 seconds from start
of microwave sensor cooking
modes.
EE05
High temperature
engine error
Engine tempera-
ture is abnormally
high.
Engine usage menu
Any time during cooking mode
but microwave
EE12
Engine thermistor fail-
ure
Break of thermistor Engine usage menu
Any time during heating
Judgment is carried out
when engine heater
has been energized for
30 or more seconds.
EE14
EEPROM failure
Data verification error
Written value does
not agree with read
value
When I/O check mode
starts
I/O check mode
Reset
AH sensor ladder
resistance level
error
After an elapse of seven (7)
minutes from start of heating
Within 1 sec.
Within 1 sec.
Within 1 sec.
(Power ON/door closed state)
[STOP/CLEAR] [STEAM CONVECTION] [MICROWAVE] [OPEN DOOR] (Set the number (initial number: 04) by [ENCODER DIAL] [START]
Software is detecting oven
stuck at too hot while in
oven mode or oven stuck
at too cold while in proof
(fermentation) mode.
EE02
NOTE:
Software and associated
A/D circuitry is measuring
values outside of normal
range for AH sensor.
Food burning while
microwave cooking
[DIRECT SETTING KEY]