background image

23

22

79–3/8”

(201.6

cm)

min.

to bottom

of

anti-tip

board

80–1/2”

(204.6

cm)

max.

to bottom

of

anti-tip

board

Note:

 If unit is installed deeper than

24” (61.0 cm), then shim behind the mounting

boards by the difference.

Note:

 If unit is installed deeper than

24” (61.0 cm), then shim behind the mounting

boards by the difference.

One 2”x 4” mounting board per unit

1–1/2” (3.8 cm) x 3–1/2” (8.9 cm)

Two 2”x 4” mounting boards per unit

3” (7.6 cm) x 3–1/2” (8.9 cm)

Bottom of anti-tip board is 3–7/8” (9.8 cm) below opening height.

Note:

Top of unit must be placed firmly under anti-tip board.

Professional

 Anti-Tip Location

Professional Integrated

 Anti-Tip Location

29”

(73.7 cm)

3–1/2”

(8.9 cm)

3”

(7.6 cm

)

29”

(73.7 cm)

29”

(73.7 cm)

3–1/2”

(8.9 cm)

1–1/2”

(3.8 cm

)

29”

(73.7 cm)

Anti-Tip Dimensions

9”

(22.9 cm)

73–3/8”

(186.4

cm)

82–7/

8”

(210.5

cm) min.

anti-tip

board

&

opening

heigh

t

84–1/

16”

(213.5

cm)

min.

anti-tip

boar

d &

ope

ning

height

71–

1/2”

(181.6

cm)

72”

(182

.8 cm

)

Profes

sional

Integrat

ed

Mod

els On

ly

24”

(61.0

cm)

Electric Outlet Location

Water Line Entry Area

Note:

 Cutout opening shown with All Freezer model on left.

Reverse water line entry if All Freezer model is on right.

For dual bottom mount installation, two water line entry areas

are required.

71–1

/2”

(181.6

cm)

72”

(182.8

cm)

Professional

Integrated

Model

s Only

6–3/

4”

(17.1

cm)

7–5/8”

(19.4 cm)

3”

(7.6

cm)

5/8”

(1.5 cm

)

5/8”

(1.5 cm)

10–1/2”

(26.7

cm)

5/8”

(1.5 cm

)

10–3/4”

(27.

3 cm)

3–5/

8”

(9.2 cm

)

Optio

nal

floor

wat

er lin

e entr

y

1”

(2.5

cm

)

See Anti-Tip

board inst

allation

6”

(15.2 cm)

9”

(22.9 cm)

Cutout Dimensions

Dual 36” Professional & Professional Integrated

Dual 36” Professional & Professional Integrated

Содержание VCFB5301LSS

Страница 1: ...nwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com F20549 EN 070210 Viking Installation Guide Built In Refrigeration Top Grille Installation Dual Installation ...

Страница 2: ...__________ 21 Cutout Dimensions Dual 30 Professional Professional Integrated ________________ 22 Anti Tip Dimensions Dual 36 Professional Professional Integrated _______________ 23 Side Trim Installation Professional Professional Integrated ________________________ 24 Grille Assembly Professional Professional Integrated _____________________________ 26 Designer Custom Dimensions Dual 30 Designer C...

Страница 3: ...or turn power disconnect switch to OFF position before removing top grille Failure to do so can result in death or electrical shock W A R N I N G TIP OVER HAZARD Appliance is top heavy and tips easily when not completely installed Keep doors closed until appliance is completely installed and secured per installation instructions Use two or more people to move and install appliance Failure to do so...

Страница 4: ...tubing in area where temperatures drop below 35 F 1 7 C Before attaching copper tubing to the unit flush at least 2 quarts 1 9 L of water through the copper tubing and into a bucket to remove any particles in the water line Viking Range Corporation is not responsible for property damage due to improper installation or water connection Connect 1 4 6 mm flexible copper tubing to household plumbing i...

Страница 5: ...bottom strap 2 Remove top cap 3 Cut carton rear approximately 1 4 0 6 cm to 1 2 5 cm from right corner with a utility knife extended 1 4 0 6 cm 4 Remove carton and exterior packaging Save cardboard shipping material to protect floor surface when installing unit Remove anti tip board kickplate and door trim pieces DF models from rear of unit Moving Unit Remove shipping brackets from skid by removin...

Страница 6: ... 29 73 7 cm 75 15 16 192 9 cm 3 19 32 9 1 cm 30 76 2 cm 27 1 4 69 2 cm Dimensions 24 11 16 62 7 cm 1 2 54 cm Between Units 9 5 32 23 3 cm 82 3 4 210 2 cm min to 84 1 16 213 5 cm max 20 3 4 52 7 cm 22 3 16 56 4 cm 75 15 16 192 9 cm 3 19 32 9 1 cm 29 73 7 cm 29 73 7 cm 30 76 2 cm 30 76 2 cm 27 1 4 69 2 cm Dimensions Dual 30 Professional Dual 30 36 Professional ...

Страница 7: ...r To front edge of side trim 22 3 16 56 4 cm To front of top grille 24 11 16 62 7 cm To front of handle endcap 27 1 4 69 2 cm Cutout width 59 1 2 151 1 cm 65 1 2 166 4 cm 71 1 2 181 6 cm Cutout height 82 7 8 210 5 cm min to 84 1 16 213 5 cm max Cutout depth 24 61 0 cm min Electrical requirements 2 115 volt 60 Hz 15 amp dedicated circuit 3 wire cord with grounded 3 prong plug attached to product Ma...

Страница 8: ... 75 15 16 192 9 cm 3 19 32 9 1 cm 30 76 2 cm 26 1 2 67 3 cm Dimensions 24 61 0 cm 1 2 54 cm Between Units 9 5 32 23 3 cm 82 3 4 210 2 cm min to 84 1 16 213 5 cm max 20 3 4 52 7 cm 23 3 8 59 4 cm 75 15 16 192 9 cm 3 19 32 9 1 cm 29 73 7 cm 29 73 7 cm 30 76 2 cm 30 76 2 cm 26 1 2 67 3 cm Dimensions Dual 30 Professional Integrated Dual 30 36 Professional Integrated ...

Страница 9: ...mp usage 30 Freezer 9 1 amps per unit 30 Refrigerator 5 7 amps per unit 36 Freezer 9 5 amps per unit 36 Refrigerator 6 5 amps per unit 36 Bottom Mount 9 9 amps per unit Inlet water requirements All Freezer only 1 4 copper tubing inlet waterline minimum 20 psi maximum 120 psi Overall interior dimensions 30 Freezer 30 Refrigerator 36 Freezer 36 Refrigerator 36 Bottom Mount 15 9 cu ft 450 liters 18 2...

Страница 10: ... 1 2 8 9 cm 3 7 6 cm 23 58 4 cm 23 58 4 cm 3 1 2 8 9 cm 1 1 2 3 8 cm 23 58 4 cm Anti Tip Dimensions 9 22 9 cm 73 3 8 186 4 cm 82 7 8 210 5 cm min anti tip board opening height 84 1 16 213 5 cm min anti tip board opening height 59 1 2 151 1 cm 60 152 4 cm Professional Integrated Models Only 24 61 0 cm Electric Outlet Location Water Line Entry Area Note Cutout opening shown with All Freezer model on...

Страница 11: ...rofessional Integrated Anti Tip Location 29 73 7 cm 3 1 2 8 9 cm 3 7 6 cm 23 58 4 cm 29 73 7 cm 3 1 2 8 9 cm 1 1 2 3 8 cm 23 58 4 cm Anti Tip Dimensions 9 22 9 cm 73 3 8 186 4 cm 82 7 8 210 5 cm min anti tip board opening height 84 1 16 213 5 cm min anti tip board opening height 65 1 2 166 4 cm 66 167 6 cm Professional Integrated Models Only 24 61 0 cm Electric Outlet Location Water Line Entry Are...

Страница 12: ...7 cm 3 1 2 8 9 cm 1 1 2 3 8 cm 29 73 7 cm Anti Tip Dimensions 9 22 9 cm 73 3 8 186 4 cm 82 7 8 210 5 cm min anti tip board opening height 84 1 16 213 5 cm min anti tip board opening height 71 1 2 181 6 cm 72 182 8 cm Professional Integrated Models Only 24 61 0 cm Electric Outlet Location Water Line Entry Area Note Cutout opening shown with All Freezer model on left Reverse water line entry if All ...

Страница 13: ...abinet side trim mounted on the right side of the refrigerator to be installed on the left side of the installation Replace with the J shaped side trim provided in the grille kit 24 Cabinet Side Trim Z Shape Cabinet Cabinet Right Hand Door Unit Left Hand Door Unit Anti Tip Lag Bolts 2x4 mounting board fastened to wall at top of cabinet opening Engage the right hand refrigerator s left side trim in...

Страница 14: ...side facing unit otherwise remove Use this bracket if 30 W product is on right side facing unit otherwise remove Use this bracket if 36 W product is on left side facing unit otherwise remove NOTE Depending on unit configuration two brackets should be removed and discarded The 72 W and 60 W grille assemblies have all four 4 brackets mounted in the proper location 66 Professional Integrated Grille b...

Страница 15: ...16 192 9 cm 3 1 2 8 9 cm 26 1 2 67 3 cm 36 91 5 cm 30 76 2 cm Dimensions 24 61 0 cm 1 2 54 cm Between Units 9 5 32 23 3 cm 82 3 4 210 2 cm min to 84 1 16 213 5 cm max 20 3 4 52 7 cm 23 3 8 59 4 cm 75 15 16 192 9 cm 3 1 2 8 9 cm 29 73 7 cm 29 73 7 cm 26 1 2 67 3 cm 30 76 2 cm 30 76 2 cm Dimensions Dual 30 Designer Custom Panel Dual 30 36 Designer Custom Panel ...

Страница 16: ...age 30 Freezer 9 1 amps per unit 30 Refrigerator 5 7 amps per unit 36 Freezer 9 5 amps per unit 36 Refrigerator 6 5 amps per unit 36 Bottom Mount 9 9 amps per unit Inlet water requirements All Freezer only 1 4 copper tubing inlet waterline minimum 20 psi maximum 120 psi Overall interior dimensions 30 Freezer 30 Refrigerator 36 Freezer 36 Refrigerator 36 Bottom Mount 15 9 cu ft 450 liters 18 2 cu f...

Страница 17: ... cm 1 1 2 3 8 cm 23 58 4 cm Anti Tip Dimensions 9 22 9 cm 73 3 8 186 4 cm 82 7 8 210 5 cm min anti tip board opening height 84 1 16 213 5 cm max anti tip board opening height 60 152 4 cm 24 61 0 cm Electric Outlet Location Water Line Entry Area Note Cutout opening shown with All Freezer model on left Reverse water line entry if All Freezer model is on right 60 152 4 cm 6 3 4 17 1 cm 7 5 8 19 4 cm ...

Страница 18: ...ed on the right Anti Tip Location 29 73 7 cm 3 1 2 8 9 cm 1 1 2 3 8 cm 23 58 4 cm Anti Tip Dimensions 9 22 9 cm 73 3 8 186 4 cm 82 7 8 210 5 cm min anti tip board opening height 84 1 16 213 5 cm min anti tip board opening height 66 167 6 cm 24 61 0 cm Electric Outlet Location Water Line Entry Area Note Cutout opening shown with All Freezer model on left Reverse water line entry if All Freezer mode...

Страница 19: ...Dimensions 9 22 9 cm 73 3 8 186 4 cm 82 7 8 210 5 cm min anti tip board opening height 84 1 16 213 5 cm max anti tip board opening height 72 182 9 cm 24 61 0 cm Electric Outlet Location Water Line Entry Area Note Cutout opening shown with All Freezer model on left Reverse water line entry if All Freezer model is on right For dual bottom mount installation two water line entry areas are required 72...

Страница 20: ...trim mounted on the right side of the refrigerator to be installed on the left side of the installation Replace with the J shaped side trim provided in the grille kit Cabinet Side Trim Z Shape Cabinet Cabinet Right Hand Door Unit Left Hand Door Unit Anti Tip Lag Bolts 2x4 mounting board fastened to wall at top of cabinet opening Engage the right hand refrigerator s left side trim into the J shaped...

Страница 21: ...erwise remove Use this bracket if 30 W product is on right side facing unit otherwise remove Use this bracket if 36 W product is on left side facing unit otherwise remove NOTE Depending on unit configuration two brackets should be removed and discarded The 72 W and 60 W grille assemblies have all four 4 brackets mounted in the proper location 66 Designer Grille back view Remove center grille blade...

Страница 22: ... spacers on the corresponding side of the installation if installing a unit on the left side of an installation its grille spacers should be installed on the left side of the unified grille Grille Assembly Bracket Placement Custom Panel Models For 66 grille excluding Custom Panel Add Remove brackets to full length grille as required See illustration below TOP Use this bracket if 36 W product is on...

Страница 23: ...mbly Install Custom Panel Models Remove center grille blade by lifting up and pulling forward Insert grille into refrigerators Screw grille assembly into units with 4 screws removed in Step 3 See Grille Removal Section ...