Installation/Programming

Operation

1.  Determine the best wiring configuration for your application (section C below).
2.  Connect the 6-wire plug (RJ25) from the TMS-RDMA to the RJ25 connector marked “SQRG-12” on the back
     panel of the TMS-6X.
Note:  The TMS-RDMA is NOT polarity sensitive to the 6-wire connection to the TMS-6X.

A.  Installing with a TMS-6X

B.  Installing with a TMS-12A

1.  Determine the best wiring configuration for your application (section C, below).
2.  Connect the 6-wire plug (RJ25) from the TMS-RDMA to one of the following:
     a.  The modular RJ25 connector marked “SQRG-12/TMS-RDMA.”
     b.  The RJ21X punch down connector.
3.  Place protocol switch 11 in the down position.
Note:  The TMS-RDMA is NOT polarity sensitive to the 6-wire connection to the TMS-12A.

C.  Recommended Maximum Run Length

Number of TMS-RDMA’s

1

2

3

Maximum Run Length

1000 feet (305 m)

400 feet (122 m)

300 feet (91 m)

Note:  2,000 foot runs are possible with optional power supply
PS-2 (Fax Back Document 510).

Important:  Use 24 gauge 6-wire cord.

E.  Wiring Configurations

1.  Three Separate Runs
     of 1000 feet

2.  Three Units on the 
     Same Run

3.  Using Optional Power Supplies

On normal incoming calls the TMS-RDMA will display the line to be answered and provide standard cadence tone burst.  This ring
represents the incoming call before the call has been answered by the TMS-6X or the TMS-12A.  In instances where one or more
lines have been answered by the TMS-6X or the TMS-12A, a double tone burst will sound.  The digital display will then indicate the
next line to answer.

300 foot maximum

2000 foot maximum

1000 foot maximum

D.  DIP Switch Settings

DIP Switch

1

2

3

On

TMS-12A

Inverted Display

Not Used

Off

TMS-6X

Normal Display

Not Used

VIKING ELECTRONICS, INC.
HUDSON, WI  54016

L4, L5, L6

MUSIC

RING VOLUME

SQRG-12

L1, L2, L3

USE ONLY
LISTED
CLASS 2
POWER
SOURCE
12-14 VAC

TMS-6X or TMS-12A

VIKING ELECTRONICS, INC.
HUDSON, WI  54016

L4, L5, L6

MUSIC

RING VOLUME

SQRG-12

L1, L2, L3

USE ONLY
LISTED
CLASS 2
POWER
SOURCE
12-14 VAC

TMS-6X or TMS-12A

VIKING ELECTRONICS, INC.
HUDSON, WI  54016

L4, L5, L6

MUSIC

RING VOLUME

SQRG-12

L1, L2, L3

USE ONLY
LISTED
CLASS 2
POWER
SOURCE
12-14 VAC

TMS-6X or TMS-12A

On    Off

Rear View of

the TMS-RDMA

TMS-RDMA

Inverted Display

(DIP Switch 2 On)

PS-2

Power

Supply

PS-2

Power

Supply

PS-2

Power

Supply

Отзывы: