![Viking TMS-RDMA Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/viking/tms-rdma/tms-rdma_user-manual_1023447002.webp)
Printed in the U.S.A.
ZF290800 Rev C
Fax Back Doc # 075
Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking
Electronics, its affiliates and/or subsidiaries assume no responsibility for errors and/or omissions contained in this information. Revisions of
this document or new editions of it may be issued to incorporate such changes.
Product Support Line...(715) 386-8666 Fax Back Line...(715) 386-4345
Installation/Programming
Operation
1. Determine the best wiring configuration for your application (section C below).
2. Connect the 6-wire plug (RJ25) from the TMS-RDMA to the RJ25 connector marked “SQRG-12” on the back
panel of the TMS-6X.
Note: The TMS-RDMA is NOT polarity sensitive to the 6-wire connection to the TMS-6X.
A. Installing with a TMS-6X
B. Installing with a TMS-12A
1. Determine the best wiring configuration for your application (section C, below).
2. Connect the 6-wire plug (RJ25) from the TMS-RDMA to one of the following:
a. The modular RJ25 connector marked “SQRG-12/TMS-RDMA.”
b. The RJ21X punch down connector.
3. Place protocol switch 11 in the down position.
Note: The TMS-RDMA is NOT polarity sensitive to the 6-wire connection to the TMS-12A.
C. Recommended Maximum Run Length
Number of TMS-RDMA’s
1
2
3
Maximum Run Length
1000 feet (305 m)
400 feet (122 m)
300 feet (91 m)
Note: 2,000 foot runs are possible with optional power supply
PS-2 (Fax Back Document 510).
Important: Use 24 gauge 6-wire cord.
E. Wiring Configurations
1. Three Separate Runs
of 1000 feet
2. Three Units on the
Same Run
3. Using Optional Power Supplies
On normal incoming calls the TMS-RDMA will display the line to be answered and provide standard cadence tone burst. This ring
represents the incoming call before the call has been answered by the TMS-6X or the TMS-12A. In instances where one or more
lines have been answered by the TMS-6X or the TMS-12A, a double tone burst will sound. The digital display will then indicate the
next line to answer.
300 foot maximum
2000 foot maximum
1000 foot maximum
D. DIP Switch Settings
DIP Switch
1
2
3
On
TMS-12A
Inverted Display
Not Used
Off
TMS-6X
Normal Display
Not Used
VIKING ELECTRONICS, INC.
HUDSON, WI 54016
L4, L5, L6
MUSIC
RING VOLUME
SQRG-12
L1, L2, L3
USE ONLY
LISTED
CLASS 2
POWER
SOURCE
12-14 VAC
TMS-6X or TMS-12A
VIKING ELECTRONICS, INC.
HUDSON, WI 54016
L4, L5, L6
MUSIC
RING VOLUME
SQRG-12
L1, L2, L3
USE ONLY
LISTED
CLASS 2
POWER
SOURCE
12-14 VAC
TMS-6X or TMS-12A
VIKING ELECTRONICS, INC.
HUDSON, WI 54016
L4, L5, L6
MUSIC
RING VOLUME
SQRG-12
L1, L2, L3
USE ONLY
LISTED
CLASS 2
POWER
SOURCE
12-14 VAC
TMS-6X or TMS-12A
On Off
Rear View of
the TMS-RDMA
TMS-RDMA
Inverted Display
(DIP Switch 2 On)
PS-2
Power
Supply
PS-2
Power
Supply
PS-2
Power
Supply