From the observing port, any of the stations can be accessed by dialing a programmable 2, 3 or 4 digit Touch Tone
dial up code.  Stations being observed are unaware that they are being monitored. Automatic gain control equalizes
in and outbound conversation levels. If assistance is required, the observer can quickly enter the conversation by di-
aling a Touch Tone “

Q

.” An audio out jack provides a microphone level signal for a tape recorder while the record

control jack provides remote operation of the tape recorder on command. Additional 

SO-24A

’s may be used to

add 24 additional stations or lines at a time.  A multi-module configuration of 

SO-24A

’s is capable of supporting

240 lines or stations.

The dial up codes are factory set to two digits (01-24).  Each 

SO-24A

in a multi-module configuration needs to be

programmed with the same number of digits for all dial up codes. To program the number of digits, use the chart
below:

C.  Setting the Number of Digits (for Dial Up Codes)

5

B.  Accessing the Programming Mode

Step 1.

Set DIP switch 2 to 

ON

for the module being programmed..

Step 2.

Come off-hook on the observing phone and dial a 

Q

.

Step 3.

Two beeps will be heard. (Modules not being programmed - status LED’s will turn off)

Step 4.

When finished programming, hang-up and set DIP switch 2 to 

OFF

.

Note:  

For multi-module systems, program each module separately.  The status LED for the module being pro-

grammed will remain lit, while all other module’s LEDs will turn off.

To Program...

Step 1:

Step 2:

... two digit dial up codes

Access 

Programming

as shown in section 

B

Enter digits:  

2 # 00

... three digit dial up codes

Access 

Programming

as shown in section 

B

Enter digits:  

3 # 00

... four digit dial up codes

Access 

Programming

as shown in section 

B

Enter digits:  

4 # 00

Important:  

All 

SO-24A

’s in a system 

MUST

be programmed with the same number of dial up code digits.

The 

SO-24A

is factory set with the dial up codes for locations 1-24 factory set to 01-24.  The dial up codes may

be programmed to match the extension number of the line/station being observed or any other numbering scheme
as long as all access codes are the same length (see section 

C

). 

Important: 

Each module must to be pro-

grammed with its own unique set of dial up codes. 

Note:

When using multiple units, see 

DOD# 943

for a pro-

gramming chart to manage dial up codes for up to 10 units.

D.  Dial Up Codes

To Program...

Step 1:

Step 2:

Step 3:

...dial up code 231 for
location 03

Access 

Programming

as

shown in section 

B

Select 3-digit dial up codes as
shown in 

Programming

section 

C

Enter:  

231 #03

...dial up code 15 for
location 15

Access 

Programming

as

shown in section 

B

Select 2-digit dial up codes as
shown in 

Programming

section 

C

Enter:

15 #15

...dial up code 2714 for
location 14

Access 

Programming

as

shown in section 

B

Select 4-digit dial up codes as
shown in 

Programming

section 

C

Enter:

2714 #14

The talk assist feature can be activated any time a location is being observed and a “

Q

” is dialed at the observing

phone.  To prevent accidental talk assist, the feature may be disabled by entering 

Q

0

while in the programming

mode (see section 

B

).  Enter 

Q

1

to enable talk assist.

E.  Talk Assist

Description

Enter  Location

To set dial up codes to two digits (factory setting) .........................................................

2

#00

To set dial up codes to three digits .................................................................................

3

#00

To set dial up codes to four digits ...................................................................................

4

#00

To program dial up codes ..............................................................................................

2-4 digits

#01-#24

To enable talk assist option (factory setting) ..................................................................

Q

1

To disable talk assist ......................................................................................................

Q

0

To set all programming features and dial up codes to factory settings .....................

###

To activate the digital recorder automatically when a station is being observed ........... set DIP switch 3 to 

ON

F.  Quick Programming Guide

Operation

Содержание SO-24A

Страница 1: ...a dedicated pair of wires be tween the handset and the SO 24A Monitor stations from an unused phone system line input or to a dedicated single line phone Add remote observing with a RAD AMP Re mote Ac...

Страница 2: ...SO 24A W BL BL W W O O W W G G W W BN BN W W S S W R BL BL R R O O R R G G R R BN BN R R S S R BK BL BL BK BK O O BK BK GN GN BK BK BN BN BK BK S S BK Y BL BL Y Y O O Y Y G G Y Y BN BN Y Y S S Y V BL...

Страница 3: ...X KSU Trunk Port Observing Phone 13 8V AC Adapter included RJ21X Male Jack not included Add up to 8 more SO 24A modules for a total of 240 stations Master Module ON OFF 1 ON OFF 1 DIP Switch 1 must be...

Страница 4: ...ON or the only module in a single module system Slave Module s Any module s in addition to the Master module used to increase capacity DIP switch 1 OFF Installation A SO 24A system consists of at lea...

Страница 5: ...in section B Enter digits 4 00 Important All SO 24A s in a system MUST be programmed with the same number of dial up code digits The SO 24A is factory set with the dial up codes for locations 1 24 fa...

Страница 6: ...Set DIP switch 3 to ON see Programming section A and all monitored conversations will be recorded If a multi module system Master and Slaves is installed set DIP switch 3 on all modules to ON E Automa...

Страница 7: ...66M150 Suttle SE 66M1 50 C5 C O Lines RJ21X Male Jack not included or 24 Analog PABX KSU Stations Supervisor 1 Module Bridge Clip the First 24 Pairs Only Punch Down Terminal Block with Split Center n...

Страница 8: ...OR RELATED TO THE SALE OR USE OF THE PROD UCT SOLD HEREUNDER EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY WHETHER IN AN ACTION BASED ON CONTRACT TORT INCLUDING NEGLIGENCE OR STRICT LIABILITY OR ANY OT...

Отзывы: