Viking RDMOR206SS Скачать руководство пользователя страница 2

2

RDMOR206SS

 

PRECAUTIONS TO BE OBSERVED BEFORE AND DUR-
ING SERVICING TO AVOID POSSIBLE EXPOSURE TO 
EXCESSIVE MICROWAVE ENERGY

(a)  Do not operate or allow the oven to be operated with the door open.
(b)  Make the following safety checks on all ovens to be serviced before activating the magnetron or other microwave 

source, and make repairs as necessary: (1) interlock operation, (2) proper door closing, (3) seal and sealing 
surfaces (arcing, wear, and other damage), (4) damage to or loosening of hinges and latches, (5) evidence of 
dropping or abuse.

(c)  Before turning on microwave power for any service test or inspection within the microwave generating compart-

ments, check the magnetron, wave guide or transmission line, and cavity for proper alignment, integrity, and 
connections.

(d)  Any defective or misadjusted components in the interlock, monitor, door seal, and microwave generation and 

transmission systems shall be repaired, replaced, or adjusted by procedures described in this manual before 
the oven is released to the owner.

(e)  A microwave leakage check to verify compliance with the Federal Performance Standard should be performed 

on each oven prior to release to the owner.

BEFORE SERVICING

Before servicing an operative unit, perform a microwave emission check as per the Microwave Measure-
ment Procedure outlined in this service manual.
If microwave emissions level is in excess of the specified limit, contact Viking Service immediately @
1-888-845-4641.

If the unit operates with the door open, service person should (1) tell the user not to operate the oven and 
(2) contact VIKING, plus the Department Of Health, Canada and/or the Food and Drug Administration's 
Center for Devices and Radiological Health immediately.

Service personnel should inform VIKING of any certified unit found with emissions in excess of 4mW/
cm

2

. The owner of the unit should be instructed not to use the unit until the oven has been brought into 

compliance.

DANGER CAUTION

HIGH VOLTAGE 

Do not energize a microwave oven with the outer case cabinet removed, because a microwave oven gener-
ates High Voltage in the circuit.

If you intend to operate the oven employing the high frequency switching power converter circuit, you should 
take special precautions to avoid an electrical shock hazard.

The high voltage transformer, high voltage capacitor and high voltage diode have energized high voltage 
potential approx. 8 KV.

The aluminium heat sink is connected to the switching power transistor Collector pole, and has an energized 
high voltage potential approx. 650V peak.

DO NOT ACCESS THE HIGH VOLTAGE TRANSFORMER, HIGH VOLTAGE CAPACITOR, HIGH VOLTAGE 
DIODE AND HEAT SINK WHEN THE POWER SUPPLY IS CONNECTED TO AN ELECTRICAL OUTLET.

Содержание RDMOR206SS

Страница 1: ...6SS OVER THE RANGE MICROWAVE OVEN MODEL RDMOR206SS TABLE OF CONTENTS Page PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY INSIDE FRONT C...

Страница 2: ...eck as per the Microwave Measure ment Procedure outlined in this service manual If microwave emissions level is in excess of the specified limit contact Viking Service immediately 1 888 845 4641 If th...

Страница 3: ...3 RDMOR206SS Notes...

Страница 4: ...the oven cavity The water container shall be a low form of 600 ml 20 oz beaker with an inside diameter of approx 8 5 cm 3 1 2 in and made of an electrically nonconductive material such as glass or pla...

Страница 5: ...the cooking control on Full Power Cooking Mode Close the door and select a cook cycle of several minutes If the water begins to boil before the survey is completed replace it with 275 ml of cool wate...

Страница 6: ...capacitor 4 Disconnect the leads to the primary of the power transformer 5 Ensure that these leads remain isolated from other components and oven chassis by using insulation tape 6 After that procedu...

Страница 7: ...te the oven until the following points are ensured A The door is tightly closed B The door brackets and hinges are not defective C The door packing is not damaged D The door is not deformed or warped...

Страница 8: ...of Full Power P 20 approx 20 of Full Power P 10 approx 10 of Full Powe P 0 No power throughout the cooking time Help pad Sensor Cook pad Auto Broil pad Auto Roast pad Auto Bake pad Sensor Reheat pad M...

Страница 9: ...ndow 2 Door hinges 3 Sirrer cover 4 Turntable motor shaft 5 Oven lamp It will light when oven is operating or door is open 6 Door latches The oven will not operate unless the door is securely closed 7...

Страница 10: ...Hi Lo Power Level Light Keep Wa rm Turnta ble O n O ff C loc k Stop C lea r Help Sensor C ook C onvec Broil C O NVEC TIO N C onvec Roa st C onvec Ba ke 1 100 F 2 150 F 3 275 F 4 300 F 5 325 F 6 350 F...

Страница 11: ...cycle when the door was opened 7 Themonitorswitchiselectricallymonitoringtheoperation of the secondary and third door door switch and primary interlock relay and is mechanically associated with the d...

Страница 12: ...r motor The damper is returned to the open position closing the damperswitchcontactswhichsendasignaltothecontrol unit de energizing shut off relay RY6 AUTOMATIC MIX COOKING CONDITION Touch the Combina...

Страница 13: ...lamp turntable motor cooling fan motor and convection motor The power supply voltage is applied to the heating element 4 Now the oven is in the convection cooking mode or Automatic Mix Cooking condit...

Страница 14: ...he customer s vent system 2 HORIZONTAL VENTING The air handing is same asVERTICALVENTING except that the final air discharge is directed horizontally out from the top rear of the oven into the custome...

Страница 15: ...3 E4 INTERLOCK RELAY PRIMARY XXX F MONITOR FUSE 20A YLW BRN WHT GRY WHT YLW GRN GRY GRY WHT NOISE FILTER CONV SIDE BLU GRY THIRD DOOR SWITCH PNK ORG ORG ORG ORG ORG PPL BRN BLK PNK BLK RED YLW BRN HOO...

Страница 16: ...O 3 Oven Schematic Convection Cooking Condition CONVEC PREHEAT BROIL SLOW COOK SCHEMATIC NOTE CONDITION OF OVEN 1 DOOR CLOSED 2 MIX COOKING PAD TOUCHED 3 DESIRED TEMP TOUCHED 4 COOKING TIME PROGRAMMED...

Страница 17: ...ARY INTERLOCK RELAY SECONDARYSWITCH DOORSENS ING SWITCH MONITOR SWITCH AND PRI MARY SWITCH FOR PROPER OPERATION REFERTOCHAPTER TESTPROCEDURE NOTE monitor FUSE PRIMARY SWITCH AND MONITOR SWITCH ARE REP...

Страница 18: ...is de energized and the convection fan stops operating and the oven shuts off DAMPER OPEN CLOSE MECHANISM Usually the damper is in the open position except during convection cooking Damper position i...

Страница 19: ...t FFS BA018 KIT as an assembly IMPORTANT Whenever troubleshooting is performed with the power supply cord disconnected It may in some cases be necessary to connect the power supply cord after the oute...

Страница 20: ...or should be operating at low speed Hood lights do not turn on with pushed Light button Hood fan motor does not rotate at all with pushed Vent button Speed of the hood fan motor does not change when t...

Страница 21: ...MOTOR HOOD LAMP OR SOCKET HOOD MOTOR CAPACITOR SHORTED OR OPENED WIRING SHORTED IN POWER CORD NO POWER AT OUTLET LOW VOLTAGE NOISE FILTER M N O P Q R S S S S S S S S S S U V RE RE RE RE CK CK RE CK R...

Страница 22: ...zes Record the temperature of the water 2 Place the cup of water in the oven Operate oven at POWER 10 HIGH selecting more than 60 seconds cook time Allow the water to heat for 60 seconds measuring wit...

Страница 23: ...omponents during testing 6 Reinstall the outer case cabinet 7 Reconnect the power supply cord after the outer case is installed 8 Run the oven and check all functions D HIGH VOLTAGE CAPACITOR TEST E S...

Страница 24: ...nt plate of the oven cavity with the door opened in this condition the plunger of the monitor switch is pushed in the meter should indicate an open circuit If improper operation is indicated the switc...

Страница 25: ...losed circuit If the temperature of the magnetron reaches approximately 302O F 150O C the temperature fuse opens An open temperature fuse indicates overheating of the magnetron Check for restricted ai...

Страница 26: ...is supplied to the damper motor the motor operates until the damper is opened and the damper switch closes Then the damper motor stops operation 5 If the damper motor does not operate check for A C vo...

Страница 27: ...ed according to the symptoms indicated Before testing 1 Disconnect the power supply cord and then remove outer case Refer to procedure of HOOD EXHAUST LOUVER REMOVAL REMOVAL OF OVEN FROM WALL and OUTE...

Страница 28: ...oor and block it open 3 Discharge high voltage capacitor 4 If the display fails to clear when the STOP CLEAR pad is depressed first verify the flat ribbon is making good contact verify that the door s...

Страница 29: ...24 0V D C Power transformer Stirrer mootor RY3 Approx 24 0V D C Heating element RY4 Approx 24 0V D C Turntable motor RY5 Approx 24 0V D C Fan motor RY6 Approx 24 0V D C Damper motor RY7 Approx 24 0V...

Страница 30: ...led before following procedure 1 The oven should be plugged in at least five minutes before sensor cooking 2 Room temperature should not exceed 95O F 35O C 3 The unit should not be installed in any ar...

Страница 31: ...sensor 6 Reconnect all leads removed from the components during replacing 7 Re install the outer case 8 Reconnect the oven to the power supply and check the sensor cook operation proceed as follows 9...

Страница 32: ...DICATION OF OHM METER Between N and H Open Circuit Between terminal N and GRY Short Circuit Between terminal H and RED Short Circuit If incorrect readings are obtained replace the noise filter 6 Recon...

Страница 33: ...the LSI are turned on in such a way as to change the resistance values in parallel with R50 1 Changing the resistancevaluesresultsinthatthereisthesamepotential at both F 3 terminal of the absolute hum...

Страница 34: ...agetransformerand Oven cavity 3 Sharp edge Bottom plate Oven cavity Waveguide flange Chassis support and other metallic plate 4 Movable parts to prevent a fault Fan blade Fan motor Switch Switch lever...

Страница 35: ...ter case Refer to procedure of RemovalofOvenfromWall and OutercaseRemoval 2 Open the door and block it open 3 Disconnect the 6 pin connector of the hood fan motor from the main wire harness located at...

Страница 36: ...nd hood intake duct R Refer to procedure of Removal of Oven from Wall Outer case Removal and Unit Mounting Screw and Hood Intake Duct R Removal 2 Open the door block it open 3 Discharge high voltage c...

Страница 37: ...move the fan blade from the shaft of the fan motor by pulling and rotating the fan blade with your hand 3 Now the fan blade will be free CAUTION Do not reuse the removed fan blade because the hole for...

Страница 38: ...er cover to the tabs on the ceiling 4 Put the stirrer fan on the stirrer cover to match the stirrer fan shaft to the center of the stirrer support 5 Hold the stirrer cover to the oven cavity with the...

Страница 39: ...forward a until b breaks as shown in step 1 2 To remove the middle section push both sides of the middle section towards d until c breaks as shown in step 2 NOTE Discard the middle section 3 Afterrem...

Страница 40: ...shaft 24 Remove the E ring from the convection motor shaft 25 Remove two 2 screws holding the convection motor to convection motor mounting plate 26 Now the convection motor is free CONVECTION DUCT A...

Страница 41: ...NDARY THIRD DOOR SWITCH AND MONITOR SWITCH ADJUSTMENT 2 Thedoorsensingswitch secondaryandthirddoorswitch interrupt the circuit before the door can be opened 3 Monitor switch contacts close when door i...

Страница 42: ...t the power supply cord and remove the oven from wall and remove outer case Refer to procedure of RemovalofOvenfromWall and OutercaseRemoval 2 Open the door and block it open 3 Discharge high voltage...

Страница 43: ...ERLOCK SWITCH N O N C COM COM MONITOR SWITCH MONITOR FUSE AND FUSE HOLDER N O N O COM COM GRN GRN PNK N O COM DOOR SENSING SWITCH CN C CN E CN F CN A RY3 RY1 RY9 RY7 CN F T1 1 2 RED WHT 3 AH SENSOR HO...

Страница 44: ...RPORATION ALL RIGHTS RESERVED Nopartofthispublicationmaybereproduced stored in retrieval systems or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise wi...

Отзывы: