Cable Requirements:

The 

PROX-1

can operate at up to *500 feet (152 m) of cable, using seven-conductor, shielded, stranded cable. Per the Security Industry

Association’s Wiegand specification, AWG 24 (such as Belden 9537) is the minimum gauge required for data transfer in a 500-foot run
length. However, the proper wire gauge to use must be determined by the current draw requirements of the reader, the length of the cable
run, and the voltage applied to the reader.

If the reader is to be operated at 5 VDC, 5 VDC must be available at the reader (long cable runs have a voltage drop due to the resist-
ance in the cable). A larger gauge of wire (having less resistance) or a separate power supply near the reader may be required to ensure
5 VDC is available at the reader.

Output Formats:

•  Wiegand (industry standard 26-bit Wiegand)
•  Magnetic Stripe (ABA Track II, clock and data, with card present)

Grounding:  

Shield (drain) continuity must run from the reader to the access panel. Shield (drain) and reader ground must be tied together at the
access panel and connect to an earth ground at one point.

Power:

The 

PROX-1

may be powered by the access panel. As such, the reader is powered on when the access panel is powered on. However

the best case is to power the reader by a separate, linear power supply. 

Voltage:

5 to 14 VDC 

Note: 

For maximum read range, a minimum of 12VDC is recommended.

FleaPowerTM Control Line:

The 

PROX-1

can be placed in a special lower power mode by pulling the purple colored fleaPower Control Line low.  This special low

power mode reduces the average power required by the reader.

I

I

n

n

s

s

t

t

a

a

l

l

l

l

a

a

t

t

i

i

o

o

n

n

Note 1:

Read range is stated in a clean RF and electrical environment using Viking Proxcards presented parallel to the

reader surface with the reader operating at 12 VDC. Additionally, read range may be affected by local installation condi-
tions. Range will be less when mounted to metal.

Note 2:

Use of a linear power supply is always recommended.

Note 3:

Minimum current draw is obtained by operating the reader in the fleaPower mode at 5 VDC with the LED off. Peak

current draw occurs when reading a card or tag.

R

R

e

e

q

q

u

u

i

i

r

r

e

e

m

m

e

e

n

n

t

t

s

s

* Note:  

When used with a Viking Entry System/Controller, see the Entry System’s Technical Practice for the maximum wire run length.

Содержание PROX-1

Страница 1: ... Read range of up to 6 inches Standard 26 bit Wiegand interface HID compatible Potted for indoor or outdoor use Pigtail connection for easy installation Red LED indicates power and flashes off during card read Transducer provides beep during card read F Fe ea at tu ur re es s P Ph ho on ne e 7 71 15 5 3 38 86 6 8 88 86 61 1 Power 5 14V DC 45mA average 80mA peak Dimensions 80mm x 43mm x 17mm 3 2 x ...

Страница 2: ...ou If you haven t followed the steps listed in 1 2 and 3 be aware that you will have to pay a restocking charge LIMITED WARRANTY Viking warrants its products to be free from defects in the workmanship or materials under normal use and service for a period of one year from the date of purchase from any authorized Viking distributor or 18 months from the date manufactured which ever is greater If at...

Страница 3: ...to an earth ground at one point Power The PROX 1 may be powered by the access panel As such the reader is powered on when the access panel is powered on However the best case is to power the reader by a separate linear power supply Voltage 5 to 14 VDC Note For maximum read range a minimum of 12VDC is recommended FleaPowerTM Control Line The PROX 1 can be placed in a special lower power mode by pul...

Страница 4: ...n and off It is up to the control panel to control dual LED and have the LED turn green when an enrolled card is presented If reader does not recognize the card tag no beep no LED flash or reader has short read range please see table below for possible causes and solutions Possible Cause Incorrect wiring Not enough power Mounted near electromagnetic interference Incorrect card used Reader access p...

Отзывы: