![Viking M.2 SATA Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/viking/m-2-sata/m-2-sata_manual_1025583015.webp)
Manual
7/24/2017
PSFEM6xxxxZxxx
Viking Technology
Revision C
Page 15 of 38
www.vikingtechnology.com
Table 2-5: STANDBY IMMEDIATE Timing
Power Cycle Endurance
Min
Max
Unit
STANDBY IMMEDIATE to WE completed
-
72.9
Ms
Notes:
1. From Standby Immediate command to NAND Write Protect enable.
2.4 Electrical Characteristics
2.4.1 Absolute Maximum Ratings
Values shown are stress ratings only. Functional operation outside normal
operating values is not implied. Extended exposure to absolute maximum ratings
may affect reliability.
Table 2-6: Absolute Maximum Ratings
Description
Min
Max
Unit
Maximum Voltage Range for Vin
-0.2
6
V
Maximum Temperature Range
-40
85
C
2.4.2 Supply Voltage
The operating voltage is 3.3V
Table 2-7: Operating Voltage
Description
Min
Max
Unit
Operating Voltage for 3.3 V (+/- 5%)
3.135
3.465
V