background image

Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or subsidiaries
assume no responsibility for errors and omissions contained in this information. Revisions of this document or new editions of it may be issued to incorporate such changes.

DOD# 246

ZF303310

 

Rev

 A

Printed in the U.S.A.

P

P

r

r

o

o

d

d

u

u

c

c

t

t

S

S

u

u

p

p

p

p

o

o

r

r

t

t

L

L

i

i

n

n

e

e

.

.

.

.

.

.

7

7

1

1

5

5

.

.

3

3

8

8

6

6

.

.

8

8

6

6

6

6

6

6

F

F

a

a

x

x

B

B

a

a

c

c

k

k

L

L

i

i

n

n

e

e

.

.

.

.

.

.

7

7

1

1

5

5

.

.

3

3

8

8

6

6

.

.

4

4

3

3

4

4

5

5

With the 

LV-1K

installed, the 

1600A Series

phone will check the telephone line on a daily basis. If dial tone is not

detected the 

LV-1K

will sound an audible beep signal every 30 seconds and continuously flash its red LED light. The

LV-1K 

also continuously monitors for loss of Talk Battery voltage and will immediately provide the same  audible and

visual indication when the telephone line has been accidentally cut or disconnected.

Once a line failure is detected, authorized personnel can silence the audible beep signals with the included key switch.
Insert the key and turn ON to the right. Two beeps will be heard, then turn key immediately OFF and remove. The LED
will remain flashing until the fault is corrected. The audible beep signals will remain silent for this event only. Future line
failure detections will sound the audible beep signals again, which can again be silenced. 

When the 

LV-1K

is actively showing a non functional telephone line state, the phone line will be watched for talk bat-

tery and dial tone to return. Once the telephone line is functional again, the 

LV-1K

will clear within five minutes. 

When used in this application, the key can be used to manually force an immediate dial tone test, (which otherwise
happens automatically once a day). With the 

LV-1K

in the normal state (not showing a failure), insert the key and turn

ON to the right. Two beeps will be heard, then turn key immediately OFF and remove. The 

LV-1K

will make a buzzing

sound indicating that it is signaling the 

1600A Series

emergency phone to check for dial tone.  If the 

1600A Series

phone is in use, the 

LV-1K

will not produce a buzzing sound because the 

1600A Series

phone will be unable to check

for dial tone. Within two minutes of the phone line becoming available, the dial tone test will run. If the phone line does
not become available within an hour, the 

LV-1K

will signal this as a fault. 

B. When Wired to the LC-6

A Viking model 

LC-6

Six Port Line Concentrator can be used for any grouping of elevators that are controlled by the

same “FIRE RECALL” switch. The 

LC-6

not only allows 2 to 6 Viking elevator emergency phones share the same 

LV-

1K

Line Verification Panel, but also allows the cost savings of those phones being able to share a single telephone

line, and still meet all requirements of ASME A17.1.  Note: The 

LC-6

additionally features the ability to install three other

service phones. A Fire Floor Phone, a Lobby Phone, and a Machine Room Phone can all call, or be called, by any of
the elevator emergency phones.

The 

LC-6

has the ability to check the incoming telephone line for operability on a daily basis. The lines running from

the 

LC-6

to each of the Viking 

1600A Series

emergency phone will also be tested at this same time. 

When a fault is detected, the 

LV-1K

will sound an audible beep signal every 30 seconds and continuously flash its red

LED light. Once noticed, authorized personnel can silence the audible beep signals with the included key switch. Insert
the key and turn ON to the right. Two beeps will be heard, then turn key immediately OFF and remove. The LED will
remain flashing until the fault is corrected. The audible beep signals will remain silent for this event only. Future line
failure detections will sound the audible beep signals again, which can again be silenced. Once the fault is corrected,
the alarm state will clear within two minutes. 

O

O

p

p

e

e

r

r

a

a

t

t

i

i

o

o

n

n

A. Single 1600A Series Phone

C. When Wired to any Other Analog Device

The 

LV-1K

will continuously monitor for loss of Talk Battery voltage indicating the telephone line has been accidental-

ly cut or disconnected. When this fault is detected the 

LV-1K 

will sound an audible beep signal every 30 seconds and

continuously flash its red LED light. Once noticed, authorized personnel can silence the audible beep signals with the
included key switch. Insert the key and turn ON to the right. Two beeps will be heard, then turn key immediately OFF
and remove. The LED will remain flashing until the fault is corrected. The audible beep signals will remain silent for
this event only. Future line failure detections will sound the audible beep signals again, which can again be silenced.
Once the fault is corrected, the alarm state will clear. 