Viking Le Maitre Freezing Pro Скачать руководство пользователя страница 3

10.) The Liquid CO2 Tank pressure as indicated on the pressure gauge must read between 300 - 340 psi to
operate the Freezefog, this is achieved by opening the pressure builder valve at least one to three hours in
advance of use by turning counter clockwise.

11.) Open Liquid valve(s) fully, by turning counter-clockwise

12) When the G300 or other smoke machine is up to operating temperature, activate the 'Smoke' button on the
remote control. The CO2 will be activated first. After the appropriate delay time passes smoke issue will start.
You will know when the gas has been purged from the supply hose by the difference in noise that the
Freezefog makes.

13.) Verify cool temperature output using your hand, by passing it through the fog output noting the
temperature.

LOW PRESSURE 350LB LIQUID CO2 TANK

The Freezefog can also use Low Pressure CO2 Cylinders similar to the one pictured to the
right.These are available from your local welding supply centre, and are sometimes referred
to as “Dewers”.  Typically there are three valve handles, a pressure gauge, and a CO2 level
indicator located on the top of the Liquid CO2 Tank. These
valves handles should be labeled as

Gas/Vent

,

Liquid

, and

Pressure Builder.

We will cover each of these below.

Gas / Vent

This is used if a CO2 gas supply is utilized. As we only use the
liquid supply to operate the Freezefog, this valve is not
opened.

Liquid

This is the source of our liquid supply of
CO2. The Freezefog CO2 supply hose is
threaded onto the valve outlet, being sure to
use the appropriate sealing washer, and
tighten to eliminate any leaks. When ready to
operate the Freezefog, open the Liquid valve
fully by turning counter clockwise.

Pressure Builder

The pressure builder is a very important
component in achieving the proper Freezefog operating pressure. We can monitor this operating pressure by
observing the pressure gauge located on the top of the Liquid CO2 Tank.

Ideally the operating pressure of the Liquid CO2 Tank is 310 - 330 p.s.i.g.  This is achieved by opening the
pressure builder valve prior to operating the Freezefog.

Technical Tip

Building the pressure to the proper level may take up to an hour, so it is suggested that the Pressure Builder
valve be fully opened one to three hours before use.

Please return this manual with your hire or a charge of £5 will be made

Page 3

Содержание Le Maitre Freezing Pro

Страница 1: ...fog consumes approximately 3 5 kilos of liquid carbon dioxide per minute of operation at 350 PSI 25bar At the typical variflow setting of 20 the Gforce3 will consume approximately 4 litres of fluid per hour constant The system can be controlled via the standard digital remote control or DMX The DMX Interface allows the Freezefog Gforce3 to be controlled on separate DMX channels Standard equipment ...

Страница 2: ... allows the liquid CO2 to purge the supply hose of CO2 gases ensuring only liquid is available for optimum cooling The recommended formula for calculating delay time is 1 sec for every three feet of supply hose Please refer to the Gforce 3 Instruction manual for use with this machine 6 Adjust the remote flow rate to desired fog output level It is recommended to start at 16 and adjust accordingly T...

Страница 3: ...vel indicator located on the top of the Liquid CO2 Tank These valves handles should be labeled as Gas Vent Liquid and Pressure Builder We will cover each of these below Gas Vent This is used if a CO2 gas supply is utilized As we only use the liquid supply to operate the Freezefog this valve is not opened Liquid This is the source of our liquid supply of CO2 The Freezefog CO2 supply hose is threade...

Страница 4: ...og may condensate on the inside of the G300 damaging the electronic components See further in this manual for suggested solutions and ducting examples Technical Tip If dividing the output to more than one location while ducting make sure the sum of all cross sectional areas of the final duct sizes is equivalent or greater than the cross sectional area of the Freezefog 10 outlet Doing this will pre...

Страница 5: ...ne from the Freezefog turn on the G300 and place your hand in the fog stream 24 away from the front of the machine Your hand should be dry You will feel a slight warming but do not confuse this for moisture If the machine is not performing properly your hand will be very wet The G300 should be serviced to rectify the problem 8 Too much fog is being pushed through the Freezefog On the High Pressure...

Страница 6: ...TIONS 1 Ensure that operation of the machine is supervised by suitably trained and authorized personnel 2 Do not modify the machine or use a machine which has been damaged in any way 3 Allow sufficient air circulation around the machine at all times 4 Protect the Gforce3 from direct weather effects and wet locations 5 Only use fluids recommended by the Manufacturer 6 Do not continue to produce Fog...

Отзывы: