A.  Entering the Programming Mode

1.  Local

2.  Remote

Programming

B.  Factory Default Settings

Step 1.

Move the 

PROG/NORM

switch to 

PROG

and plug an analog phone into the 

TELCO

jack.

Step 2.

After taking the phone off hook, wait for two beeps.

Step 3.

Program as shown in sections 

B-T

.

Step 4.

To exit programming, hang-up. Set the 

PROG/NORM

switch to 

NORM

Step 1.

Make sure the 

PROG/NORM

switch is set to the 

NORM

position and that there is a CO line or

analog PABX/KSU extension in the 

TELCO

jack.

Step 2.

Call into the 

K-2000-DVA

on that line or extension. The unit will answer after the set ring delay

(see 

Programming

section 

G

) and a single beep should be heard.

Step 3.

Enter a 

Q

and the six-digit security code (factory default is 

845464

). If the correct code is entered,

two beeps should be heard.

Note:

The security code must be entered within 20 seconds otherwise the 

K-2000-DVA

will time

out and hang up.  When in programming, if 20 seconds elapse without Touch Tones being
entered or a message being recorded, the 

K-2000-DVA

will automatically exit programming and

hang up.

Step 4.

Program as shown in sections 

B-T

.

Step 5.

To exit programming, hang-up. After the 20 second timeout has elapsed, the 

K-2000-DVA

will

be ready for normal  operation. Alternatively, dial 

##7

and the 

K-2000-DVA

will immediately be

ready for normal operation

Note:

Correct programming entries are implemented and then acknowledged by two beeps. Incorrect

programming entries are discarded and receive three beeps to indicate an error.

Security Code

845464 (V-I-K-I-N-G) (see section 

D

Access Code

123456 (see section 

F

)

Alarm Dialer Mode

Enabled (see section 

E

)

Store Caster Mode

Disabled (see section 

E

)

Phone Numbers

Not Programmed (see section 

O

)

Messages

Not Recorded (see section 

R

)

Ring Delay

1 (see section 

G

)

Ringback Limit

6 (see section 

H

)

Pager Number

Not Programmed (see section 

P

)

Call Progress Detection

Enabled (see section 

J

)

Dialing Speed

Normal (see section 

I

)

Alarm Input Configuration

N/O (Enabled) Momentary (see section 

K

)

Lap Counter

1 (see section 

L

)

Message Repeat Counter

2 (see section 

L

)

Qualifier Timer

0 - disabled (see section 

M

)

Resume Timer

0 - disabled (see section 

N

)

Hookswitch Flash Before Dialing

Disabled (see section 

Q

)

Содержание K-2000-DVA

Страница 1: ...ngback limit for call progress Remote security and access codes Store caster mode Local or remote programming and recording RS 232 port for programming via a PC Compatible with the Viking RC 2A and RC 3 remote DTMF controllers Phone numbers may be programmed as pager numbers no voice message played Programmable hookswitch flash before dialing Line level input for loading pre recorded messages into...

Страница 2: ... per call In the Store Caster Mode this is the number of times the message is repeated per closure In the Store Caster Mode if the closure is still in effect when the Message Repeat Count has been met the K 2000 DVA will reset the message repeat counter and play the message until the Message Repeat Counter has been met again The Message Repeat Count is set individually for each input and can be fr...

Страница 3: ...232 9 Pin Straight Through Cable not included INPUT 1 COMMON INPUT 2 INPUT 3 COMMON INPUT 4 INPUT 8 COMMON INPUT 7 INPUT 6 COMMON INPUT 5 Earth Ground Line Level Record Input 600 Audio Output ON 1 2 Learn Sensitivity ON OFF Normal Reduced Volume Control DIP switch 1 leave OFF DIP switch 2 typically left ON If false triggers occur because of very long wire runs to the inputs move DIP switch 2 to OF...

Страница 4: ... recorded the K 2000 DVA will automatically exit programming and hang up Step 4 Program as shown in sections B T Step 5 To exit programming hang up After the 20 second timeout has elapsed the K 2000 DVA will be ready for normal operation Alternatively dial 7 and the K 2000 DVA will immediately be ready for normal operation Note Correct programming entries are implemented and then acknowledged by t...

Страница 5: ...isabled 1 digit 92 To program the Ringback Limit 01 99 2 digits 93 To program the Forced Play Timer 01 99 seconds 00 clear 2 digits 94 To record messages for each input 1 8 Q1 Q8 To clear one message Q1 Q8 then immediately press any digit To add a 4 second pause anywhere in the dialing string Q9 To add a Q anywhere in the dialing string QQ To add a anywhere in the dialing string Q To set to alarm ...

Страница 6: ...s XY where X is the input number 1 8 and Y is the dialing order 1 8 of the eight memory locations for this input In the majority of alarm dialing applications the K 2000 DVA simply goes off hook on the phone line or PBX extension pauses one second then begins dialing the programmed phone or pager number In a few alarm dialing applications the K 2000 DVA must go off hook on the phone line or PBX ex...

Страница 7: ... number on the list for that input If all numbers have been dialed and the alarm is still not reset the K 2000 DVA increments the lap counter for that input and starts the dialing process over again This will continue until the lap counter has been met At this point the K 2000 DVA marks the input as an alarmed input and returns the input to its rest state If an alarm input is reset the manner in w...

Страница 8: ...ELATED TO THE SALE OR USE OF THE PRODUCT SOLD HEREUNDER EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY WHETHER IN AN ACTION BASED ON CONTRACT TORT INCLUDING NEGLIGENCE OR STRICT LIABILITY OR ANY OTHER LEGAL THEORY ANY LIABILITY OF VIKING SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF THE PRODUCT OR AT VIKING S OPTION REFUND OF THE PURCHASE PRICE AS THE EXCLUSIVE REMEDY AND ANY LIABILITY OF VIKING SHAL...