background image

6

PC Requirements

PC Programming

Typical Installation on SIP Based VoIP Phone System

(Extends range of cable, keeps 

1 Gbps network speed for other 

equipment on network)

SIP VoIP PBX

or

PC with

SIP Server

Software

100m (328 ft) maximum*

Viking supplies

Customer’s 

Responsibility

Internet

10/100 Mbps

Maximum

Viking

K-1900-8-IP
VoIP Phone

* Note: 

A PoE extender can be used for an additional 100 meters per extender. For longer runs (up to 2 km / 1.2 miles) 

a ethernet to fiber media converter can be used.

Optional

PoE Injector

(If VoIP PBX does 

not have PoE)

Optional 

Switch / Hub

LED 7

LED 5

LED 8

LED 6

LED 3

LED 2

LED 1

LED 9

LED 4

1

2

3

on

4

MAC:

18E80FXXXXXX

asdesaxtff

C      NO     NC

RL 1

C      NO     NC

RL 2

C      NO     NC

RL 3

C      NO     NC

RL 4

1    2   3    4

NETWORK

1 2 3 4

NETWORK

VIKING

ELECTRONICS

HUDSON, WI 54016

NETWORK ENABLED

RELAY CONTROLLER

MODEL RC-4A

©

VIKING

1

IN1  C

IN2 IN3  C

IN4

2

3

4

5

6

LOGIC LEVEL
PROGRAMMING
RESTORE DEFAULTS
DEBOUNCE

PO

W

E

R

 1

2V 

DC

RELAY 1

RELAY 2

RELAY 3

RELAY 4

1

2

3

4

5

7

8

9 10 11 12

6

STATUS

LED

Optional Viking model 

RC-4A Secure Remote 

Relay Controller, see 

page 6 (DOD 582)

•  IBM 

compatible personal computer with:

Windows 7, 8 or 10

•  

Adobe Acrobat Reader 8 or higher

•  K-1900-8-IP

hardware

•  

Available LAN with PoE (class 2, <6.5 watts)

•  

Ethernet cable ( CAT5 min.)

•  

1 MB minimum free hard drive space for installation

•  16MB of free physical RAM

Download and install the programming software

1.  Go to www.vikingelectronics.com and enter 

K-1900-8-IP or K-1900-812L-IP 

in the search box

2.  Click 

K-1900-8-IP or K-1900-812L-IP 

in the search results

3.  Scroll down the page to Downloads, click 

IP Programming Software

4.  Install the programming software by saving or opening the file and then clicking on 

setup Viking IP

Programming.exe

5.  Follow the prompts on your screen to complete software installation.
6.  To start the Viking IP Programming application, click on the Viking IP Programming icon on your desk

top. The Main screen will appear, allowing the user to program any 

K-1900-8-IP Series

connected to

that LAN.   

Note:  

PC must be connected to the same LAN as the 

K-1900-8-IP Series

.

Содержание K-1900-8-IP

Страница 1: ...code or proximity card was used request for exit usage and whether it was an inbound or outbound call The K 1900 812L IP and K 1900812LIPEWP have a 12 long armored cable with internal stainless steel lanyard for additional cable strength The K 1900 8 IP EWP and K 1900812LIPEWP shares all of the features of the K 1900 8 IP and K 1900 812L IP in addition to Enhanced Weather Protection EWP for outdoo...

Страница 2: ...ng rough in box 5 0 x 10 0 x 5 53 127mm x 254mm x 141mm Dimensions for K 1900 8 IP EWP and K 1900812LIPEWP Models Phone only 5 0 x 10 0 x 4 75 127mm x 254mm x 121mm Including rough in box 5 0 x 10 0 x 5 61 127mm x 254mm x 143mm Shipping Weight for K 1900 8 IP and K 1900 8 IP EWP 5 3 lbs 2 4 kg Shipping Weight for K 1900 812L IP and K 190012L8IPEWP 5 3 lbs 2 4 kg Operating Temperature 40 F to 140 F...

Страница 3: ...Protocol is an Internet protocol standard that specifies a way for programs to manage the real time transmission of multimedia data over either unicast or multicast network services Server A computer or device that fulfills requests from a client This could involve the server sending a particular file requested by the client Session Initiation Protocol SIP Is a signaling communications protocol wi...

Страница 4: ...put Output For connecting optional Proximity Card Readers see Viking models below right not included or program as a output to connect to the card reader input of an Access Control System 12 VDC Power Output for VE LIGHT etc 12VDC 50mA max Brown Violet White Model PRX 1 Proximity Card Reader DOD 221 Optional Viking Proximity Card Readers Model PRX 3 Medium Range Proximity Card Reader DOD 228 Note ...

Страница 5: ...screws or surface mount using any of Viking s VE 5x10 Series surface mount boxes DOD 424 Note Four extra screws and nuts are provided to fill the unused mounting holes Viking s optional Surface Mount Boxes model VE 5x10 shown below are designed to be surface mounted to a wall post single gang box or a Viking gooseneck pedestal model VE GNP shown below The K 1900 8 IP Series phone can also be mount...

Страница 6: ...AY 1 RELAY 2 RELAY 3 RELAY 4 1 2 3 4 5 7 8 9 10 11 12 6 STATUS LED Optional Viking model RC 4A Secure Remote Relay Controller see page 6 DOD 582 IBM compatible personal computer with Windows 7 8 or 10 Adobe Acrobat Reader 8 or higher K 1900 8 IP hardware Available LAN with PoE class 2 6 5 watts Ethernet cable CAT5 min 1 MB minimum free hard drive space for installation 16MB of free physical RAM Do...

Страница 7: ...le shoot the failure B Connect Disconnect Open the Viking IP Programming software on the PC and the start screen shown below will appear Any Viking IP phones that are connected to the network will appear on the list Simply select the K 1900 8 IP Series on the list and click on the Connect button at the bottom or double click the selected phone If the security code of the selected phone is still se...

Страница 8: ... window appears enter the unit s security code factory set to 845464 then click OK Step 4 The program will then read and display the K 1900 8 IP Series phone s IP and programming settings Step 5 Click on the IP Settings tab Step 6 Select the appropriate value Static IP Settings or DHCP for Set Unit IP Address via Note changing the IP address will cause you to have to reconnect to the unit Enter th...

Страница 9: ...for all not SIP and RTP packets in the PCP for all packets input 0 is default priorities are from low to high 0 1 2 3 4 5 6 7 Set the PCP for SIP packets 3 is default Set the PCP for RTP packets 5 is default D Configuring K 1900 8 IP VLAN Settings F Manually Resetting All Network Parameters to Factory Default Step 1 Power down the K 1900 8 IP phone by disconnecting the LAN Cable RJ45 plug Step 2 T...

Страница 10: ...elay Mode must be set to Door Strike 21 16 In Band Audio Call Progress Enabled Disabled factory set to Enabled 22 16 In Band Audio Detect Sensitivity 1 9 1 minimum 9 maximum factory set to 5 power cycle unit after setting 23 16 Handset Default Volume 24 16 Phone Mode Auto Dialer or Manual Dial Phone factory Set to Auto Dialer 25 16 Call Length Time Out disabled or 1 9 minutes factory set to 3 minu...

Страница 11: ...alternate SIP server will be limited to 31 characters 6 Register Fails Re Resolve or Alternate Server 4 Outbound Proxy If your SIP provider requires an outbound proxy IP address enter it in the Outbnd Proxy field If outbound proxy is not required enter the SIP sever IP address into the Outbnd Proxy field Note If not required this field must match your SIP server IP address 5 Authentication ID If y...

Страница 12: ... there is no answer or a busy signal is detected the K 1900 8 IP Series phone will then dial the Roll Over Phone Number The Primary Phone Number programmed in Index 0 is the number that is dialed when the handset is lifted and the visitor does not dial any digits on the keypad before the off hook dial delay timer has expired if Off Hook AutoDial is enabled A second Roll Over Number will be dialed ...

Страница 13: ...of two file formats Tab Delimited Text or Comma Separated Variable 9 Entry Code Database Clicking on the Entry Code Database button will open the Entry Code Database screen The Entry Code Database will then download The Entry Code Database will allow you to program the Relay Function Relay 1 and or 2 once only one time use only Entry Type Card Keyless or both Keyless Code Proximity Card Facility C...

Страница 14: ...ion will be used as an input or an output The default setting for direction is Inbound and this is the correct setting if you intend to connect a card reader or Wiegand keypad device to the wiegand connections When the direction is set to outbound the 26 bit Wiegand connections become an output and can be connected to the card reader input on the access control system Unprogrammed keyless entry co...

Страница 15: ...ate continuously for the duration of any inbound or outbound call to or from the Entry phone This mode is useful for turning on IR flood lights for VoIP phones with cameras etc Doorbell Mode When programmed for Doorbell Mode the relay will momentarily activate the relay for the preprogrammed relay activation time on any outbound call from the Entry phone This mode is useful for activating a door c...

Страница 16: ...tch commands can be useful in applications where you want to eliminate the possibility of inadvertently entering a latch command leaving a gate open closed etc The relays can still be activated with the Relay Activation Command for momentary closures Factory Setting Enabled 25 Phone Mode The Phone Mode can be programmed to one of two settings Auto Dialer or Manual Dial Phone When set to Auto Diale...

Страница 17: ...t audio from the handset volume level is still normal Ring Low In the low mode the phone will output a ring signal out of the earpiece in the ring pattern selected in Ring Cadence The call can then be answered by taking the handset off hook Ring High In the High mode the phone will output a slightly louder higher pitched ring signal out of the earpiece in the ring pattern selected in Ring Cadence ...

Страница 18: ... mail etc If your VoIP phone system does not automatically convert out of band DTMF to In Band after the call is answered set In Call Dialing Format to Inband DTMF Factory Setting RFC 2833 32 Off Hook Dialing Delay The Off Hook Dialing Delay is the length of time a user hears simulated dial tone after picking up the handset before they are routed to the Primary phone number in the Phone Number Dat...

Страница 19: ...n alternative method of updating can be done by clicking the IP firmware Update IP button You can then browse to the folder that contains the PIP file for updating the unit s IP firmware This method is typically only used when Viking Technical Support has sent you updated IP firmware The Import Export feature is useful for backing up all the K 1900 8 IP Series phone s programming or for importing ...

Страница 20: ... Mode set to Manual Dial Phone When the handset is lifted in the Manual Dial Phone mode the user hears dial tone Any keypad entries dialed by the user are gathered and sent to the SIP phone system just like a standard VoIP phone Proximity cards can be scanned at any time even while a call is in progress In any of the above modes relay activation commands can be entered or can be dialed from the re...

Страница 21: ...d with primary and rollover phone numbers to route the calls appropriately Some delay must be programmed for Off Hook Dialing Delay to give the user time to dial the 911 before they are automatically routed to another number or hear 3 beeps Note 1000 is the total number of Keyless Entry Codes and or Proximity Card numbers that can be programmed in the Entry Code Database Note Read range depends on...

Страница 22: ...y 4 Output Contacts 5A 30VDC 250VAC max Connect to Doorstrike Mag Lock Gate Controller etc 2 Gel Filled Butt Connectors included Doorstrike Magnetic Lock 120V AC Door near Entry Phone 3 1 IN1 C IN2 IN3 C IN4 2 3 4 5 6 Relay 1 Output Contacts 5A 30VDC 250VAC max Connect to Doorstrike Mag Lock Gate Controller etc Relay 3 Output Contacts 5A 30VDC 250VAC max K 1900 8 IP Entry Phone 2 K 1900 8 IP Entry...

Страница 23: ...gned to be surface mounted to a wall post single gang box or a VE GNP gooseneck pedestal Note The VE 3x5 is not compatible with the VE GNP pedestals and is not available in stainless steel The VE GNP gooseneck pedestals are designed to be used with the VE 5x5 VE 6x7 and VE 5x10 backboxes and are ideal for drive up communications Note The VE 3x5 is not compatible with the VE GNP pedestals Control R...

Страница 24: ...oth Black and Ash Off White covers standard See DOD 221 for more information PRX 3 PRX 1 125KHz Proximity Cards The PRX C and PRX C ISO are non contact security cards that can be presented to the front of a K 1770 75 IP proximity card reader to allow entrance into a secured area The PRX C is a clam shell card made made from 0 070 thick plastic to resist bending and folding A slot is provided at on...

Страница 25: ...in to the dispatcher the reason for the call Perform such tests in off peak hours such as early morning or late evenings PART 15 LIMITATIONS This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a co...

Отзывы: