Viking K-1205 Скачать руководство пользователя страница 6

F. Door Strike Time

The actual time the door strike relay is energized is controlled by location 

#40

. The time can be set from 00 to 99 seconds, (an entry

of “00” gives 0.5 seconds). In order to use this feature, be sure the relay door strike code is set (see section 

G

).

6

E. Speed Dial Numbers

The 

K-1205

Entry Controller can be programmed with up to twelve 46 digit numbers. Each number can also be programmed with

special features such as pauses, and the Touch Tones “

Q

” and “

#

”. Each of the special characters count as a single digit. Each of

the speed dial positions 

#01

to 

#12

pertain to the corresponding button on the front of the 

K-1205

. The button “

0

” uses position 

#10

,

the “

Q

” uses position 

#11

and the “#” uses position 

#12

. To program a speed dial position, enter programming (see section 

A

) then

enter the desired number followed by the selected position. To clear a position, only enter a “

#

“ followed by the position number with

out any preceding number. The 

K-1205

also has the capability to dial a second phone number if there is no answer or busy at the

first number. This can be used if the tenant wants the visitor to call their cell phone if they are not at home. To program a second
number, be sure that position 

#43

is programmed with the desired maximum ring time, then enter the first number to be dialed, fol-

lowed by “

#24

”. A single beep should be heard. Next enter the second number to be dialed followed by “#“ plus the memory loca-

tion. The total number of digits cannot exceed 46 for each position (45 digits if two numbers are programmed).The following are
examples of speed dial number entries:

B. Security Code (memory location #47)

This six digit number can be used to access the programming mode. The security code has been factory set to 

845464

(V-I-K-I-N-

G). It is recommended that you change the security code to a personal 6 digit number. To change the security code, access pro-
gramming (see 

Programming

section 

A

). Enter six digits 0-9 followed by 

#47

. If you have forgotten your security code, follow the

steps in 

Programming

section 

A, 2. Accessing the Programming Mode Without the Security Code)

.  

Note:

The security code

must be six digits in length and can NOT contain a 

Q

or #.

C. Keyless Entry Codes

The 

K-1205

can be programmed with up to 50 keyless entry codes. This feature allows a visitor to let themselves in by entering a

preprogrammed code on the 

K-1205

keypad. Each keyless code can contain from 1 to 6 digits and is programmed by entering the

digits into any of the locations

#50

to 

#99

. To clear a location enter “

#

” followed by the position number without any preceding num-

ber. The “

Q

” and “

#

” keys can also be used in the keyless codes by substituting “

#20

” and “

#21

” (respectively) when programming

a keyless position. 

D. Quick Programming Features

The 

K-1205

is programmed through the incoming phone line. The programming commands are structured so that they do not

interfere with the commands of a 

C-1000B

controller.

#01

-

#12

#40
#41
#42
#43
#44
#45
#47

#50 - #99

- then - Enter Memory Location

Speed dial numbers  ..................................................................................................
Door strike time in sec (factory 05, 00 =.5 sec)**........................................................
Door strike code (factory 6, no digits disables) ..........................................................
Maximum call time in min (factory 3, 0 = .5 min, no digits disables)**  .......................
Maximum ring time in sec (factory 20, 00 disables)**  ...............................................
Silence Time Out in sec (factory 10, 00 disables)**   ..................................................
Talk/listen delay time in .1 sec (factory 2)**  ...............................................................
Security code (factory 845464)** ...............................................................................
Keyless entry codes ..................................................................................................
Dial a (

Q

)  ..................................................................................................................

Dial a (#)  ...................................................................................................................
Add a 4 second pause  ..............................................................................................
Add a 1 second pause  .............................................................................................
Second phone number selector  ................................................................................
Normal dialing speed*  ..............................................................................................
Fast dialing speed .....................................................................................................
Hang up on dial tone enable*  ...................................................................................
Hang up on dial tone disable  ....................................................................................
Reset all programming to factory default settings  ...................................................
Hang up from programming ......................................................................................

0-46 digits***
2 digits
1-2 digits
1 digit
2 digits
2 digits
1 digit
6 digits
1-6 digits
#20
#21
#22
#23
#24
#30
#31
#32
#33
###
##7

Enter Digits

then
then
then
then
then
then
then
then
then

Step 2 - Enter Digits

5551234#01

9#233334444#07

23#20#21#08

22#24 

(beep) 

33#12

Step 1 (see section A)

Enter programming

Enter programming

Enter programming

Enter programming

To Program the K-1205 to...

...store 555-1234 at the first button position

...store a 9, a 1 second pause, then 333-4444 in the seventh button position

...store a 23

Q

# in the eight position

...store a first number of 22 and a second number of 33 in the “#“ 

button position

*Factory settings
** Cannot contain “

Q

“ or “#“ 

(see #20 and #21)

*** 

45 digits maximum if two numbers are pro-

grammed in one memory location

Notes:

1. A single or double beep indicates a

valid entry, three beeps indicate an error.  2.

Q

“ or “#“, pauses or second phone number

selector occupy one digit of memory

.

Содержание K-1205

Страница 1: ...ouvered 316 stainless steel faceplate with permanent laser etched graphics stainless steel speaker mic screen heavy duty metal keypad and hex drive mounting screws Weather Resistant Features Marine gr...

Страница 2: ...NTRACT TORT INCLUDING NEGLIGENCE OR STRICT LIABILITY OR ANY OTHER LEGAL THEORY ANY LIABILITY OF VIKING SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF THE PRODUCT OR AT VIKING S OPTION REFUND OF THE PURC...

Страница 3: ...applications use the K 1205 EWP The K 1205 can either be installed as a flush mount unit using the included rough in box or as a surface mount unit using an optional VE 5x10 The rough in box uses the...

Страница 4: ...ivers go to www northernvideo com Caution When routing CAT5E or CAT6 cable maintain a minimum distance of 3 ft from any parallel high voltage wire 110 VAC and a minimum of 2 ft from crossing any high...

Страница 5: ...DOOR BOX 1 DOORBOX 13VAC PWR DOOR BOX 2 N O COM N C DOOR STRIKE 1 SIG GND VIDEO 1 IN SIG GND VIDEO 2 IN SIG GND VIDEO OUT N O COM N C DOOR STRIKE 2 TALK BATTERY OFF ON C LED1 C LED2 C LED3 ON 1 2 3 CO...

Страница 6: ...and can NOT contain a Q or C Keyless Entry Codes The K 1205 can be programmed with up to 50 keyless entry codes This feature allows a visitor to let themselves in by entering a preprogrammed code on...

Страница 7: ...ut any pre ceding numbers The following are examples of door strike code entries Microphone Sensitivity POT ON OFF 1 2 3 4 Speaker Volume POT 1 2 3 on 4 Switch 1 1 2 3 2 3 4 4 Position ON OFF ON OFF O...

Страница 8: ...e buttons that have a programmed phone number are active except when used for keyless entry After a button is pressed and the call is initiated it can be canceled by momentarily pressing any button on...

Отзывы: