CLEANING THE RESERVOIR & IRRIGATION SYSTEM 

1. 

Make sure cabinet is connected to city drain and water

.  If you are not hooked up to a drain and city water you will need to manual-

ly drain and fill the cabinet; if this is the case, connect the drain fitting to a hose that runs to a drain or sink. Do not activate the DRAIN 
function until you have a place to drain the water with a hose to a sink or drain, observing all municipal codes. Used water from the 
cabinet is not potable. 

2. 

Remove the bottom drawer(s) 

3. 

From the HOME screen, press SETUP 

4. 

In the SETUP screen, press SET RESERVOIR 

5. 

Press DRAIN.  The next screen that appears will ask if you are sure.  Double check that the cabinet is hooked up to a drain.  Otherwise it 
will drain onto your floor! If you are not sure, press no and double check.  If you are sure, press YES. 

6. 

The cabinet will start to drain the reservoir.  This may take up to 20 minutes.  Once the reservoir has been drained, wipe off any dirt 
with a clean rag. 

7. 

Add your preferred cleaning solution (i.e. hydrogen peroxide mixture) into the reservoir.  Follow the guidelines on the label of the 
agent.  The capacity of the GCV12 is 3.25 gallons.  H

2

O

2

 concentration should be 5 tsp per one gallon of water. 

8. 

From the HOME screen, press SET RESERVOIR, then FILL.  Filling should take approximately 20 minutes. 

9. 

When the reservoir has refilled, from the HOME screen press ZONE 1 and then WATER NOW so that the cleaning solution flows through 
the cabinet’s piping system to ZONE 1 

10.  Repeat step 9 for ZONE 2 

11.  Once the zones and reservoir are cleaned, from the HOME screen, press SETUP, SET RESERVOIR, then RECYCLE.  This will drain the reser-

voir of the cleaning solution and then refill it with fresh water for your next growing cycle. 

Step 3 

CLEANING AND MANTENANCE 

Step 4 

Step 5 

Step 5 

Step 6 

Step 8 

Step 9 

Step 9 

Step 11 

Step 11 

Step 11 

Step 11 

Содержание GCV12 Series

Страница 1: ...Use Install GUIDE Under counter Micro Green Herb Cabinet GCV12...

Страница 2: ...NCTIONS OF THE MAIN RESERVOIR SCREEN 14 PLANTING GROWING 15 GROWING GUIDE 16 GROWING DO S AND DON TS 17 CLEANING AND MAINTENANCE 18 19 PERIODIC MAINTENANCE PROCEDURES 20 REPLACING THE LIGHTS 21 SANITA...

Страница 3: ...growing trays and 5 domes CONTROLS Touchscreen digital controls Automated system provides correct measures of water nutrients relative hu midity lighting on optimum cycle for plant growth and nutrien...

Страница 4: ...ED 1 VISIBLE LOSS OR DAMAGE Be certain that any visible loss or damage is noted on the freight bill or express receipt and that the note of loss or damage is signed by the delivery person 2 FILE CLAIM...

Страница 5: ...en sink in a wet basement or near a swimming pool and similar areas 7 DO NOT operate this appliance if it has a damaged cord or plug if it is not working properly or if it has been damaged or dropped...

Страница 6: ...fittings at the back of the unit Access to the connections will be at the back of the cabinet NOTE This unit is to be installed with adequate backflow protection to comply with all applicable federal...

Страница 7: ...7 CUTOUT DIMENSIONS...

Страница 8: ...following the start up screen To unlock the screen press any button and a number pad will appear Enter 1551 then Note when the cabinet sits for long periods of time or it is turned off and then on ag...

Страница 9: ...r and gently wash the pH probe in the water and dry on a clean cloth Fig 2 Blue PH sensor shown with cap on Fig 3 PH buffer 4 Fig 4 PH buffer 7 water 5 Gently swish the probe in the pH buffer 4 Contin...

Страница 10: ...reservoir Fig 1 2 Locate the TDS sensor probe on the right side of the reservoir Fig 2 Fig 2 TDS sensor black 6 To enter the TDS calibration screen press SETUP A SET RESERVOIR B TDS SENSOR C then CALI...

Страница 11: ...N position and water should be flowing downwards into the reservoir 2 From the HOME screen choose ZONE 2 A This will be the growing zone that is directly above the pump Press WATER NOW B 3 Open 1 4 cl...

Страница 12: ...the zones for special seeds or changing the lighting and watering cycles for each plant On the HOME screen B select the zone for the seed you would like to program GCV12 2 zones On the zone screen C p...

Страница 13: ...mats etc You may also change the duration of the watering cycle anywhere between 1 and 10 minutes Press the and buttons to increase or decrease the minutes The default is 5 minutes Press BACK when yo...

Страница 14: ...ZONE screen for the particular cycle you want the cancel Press RESTART CYCLE This will cancel the existing cycle and automatically start a new cycle You will see the day counter on the top right of t...

Страница 15: ...T MOIST UNSIFTED SOIL IN TRAY S FILL TO 1 2 TO 3 4 FULL AND SMOOTH 6 MEASURE OUT SEED QUAN TITY AND SEED EVENLY WITH SHAKER see amounts in Growing Guide p 15 SPRINKLE JUST ENOUGH SIFTED SOIL OVER SEED...

Страница 16: ...weeks 1 every 4 days 1 3 oz 40g Mizuna 1 tbsp 2 3 days 2 weeks 1 every 4 days 4 oz 124g Mustard 1 tbsp 2 3 days 2 weeks 1 every 4 days 6 4 oz 200g Nasturtium 1 2 cup 4 7 days 1 2 weeks 1 every 4 days...

Страница 17: ...of media that are available For discussion on hydroponic growing media consult www epicgardening com DON T OVERFEED Overfeeding can cause damage to plants For best results follow the instructions on...

Страница 18: ...he cabinet will start to drain the reservoir This may take up to 20 minutes Once the reservoir has been drained wipe off any dirt with a clean rag 7 Add your preferred cleaning solution i e hydrogen p...

Страница 19: ...er keep a close eye on the environment and immediately clean any mold or organic matter Do not use any chemically damaging or toxic cleaning products such as bleach Do not use stainless steel cleaner...

Страница 20: ...g in soil or hydroponic media Once you get through a few growing cycles you will be able to determine how often it should be changed One indicator the filter needs to be changed is inadequate water fl...

Страница 21: ...the back of the cabinet push up the front until it clears the front of the diffuser frame pull forward and drop into place Push up and back over notch in back of cabinet then let front drop down Occas...

Страница 22: ...lean water then finish soaking time if required in clean water Avoid breathing the fumes of chlorine Masks should be worn to filter the fumes is you choose this method Using Hydrogen Peroxide Soak see...

Страница 23: ...enance on my cabinet The cabinet requires frequent monitoring and care It should be inspected thoroughly and cleaned at least once a month This may vary with your usage depending on the number and typ...

Страница 24: ...dy When you re spreading your seed out in trays it can be difficult to get an even spread If you plant too densely they will clump together espe cially if their mucilaginous When they sprout a few of...

Страница 25: ...eeds purchase from reputable supplier Sifter to sift dry soil to cover seeds for germination Plant food for hydroponic growing or seeds with longer growing cycles Seeds with shorter growing cycles get...

Страница 26: ...cs Flora Series Fox Farm Gringo Rasta Bush Doctor and Hydroponic Trio TDS reader Milwaukee Plastic tub for mixing and sifting soil Rubbermaid Growing mats filters Handy Pantry For discussion on hydrop...

Страница 27: ...istaltic pump 12VDC 18614 0124 water filter replacement cartridge 18614 0033 solenoid valve 3 8 tube 5 16 ORF 18615 0166 3 8 bulkhead tube fitting Part Number Description 18616 0451 power supply 12 VD...

Страница 28: ...Using unauthorized parts may cause serious injury or damage to the cabinet Replacement parts should be installed by a qualified service technician Contact Viking Range Preferred Service at 888 845 46...

Страница 29: ...eplacement parts Using unauthorized parts may cause serious injury or damage to the cabinet Replacement parts should be installed by a qualified service technician Contact Viking Range Preferred Servi...

Страница 30: ...ever required The serial number and model number for your appliance are located on the serial tag Model No ______________________________________________ Serial No ______________________________ Date...

Страница 31: ...ty period after a reasonable number of attempts by the warrantor to remedy the defect or malfunction the owner is entitled to either a refund or replacement of the product or its component part or par...

Страница 32: ...ge LLC 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 845 4641 or visit the our web site at vikingrange com in the US or brigade ca in Canada 065974 0...

Отзывы: