18
CLEANING THE RESERVOIR & IRRIGATION SYSTEM
1.
Make sure cabinet is connected to city drain and water
. If you are not hooked up to a drain and city water you will need to manual-
ly drain and fill the cabinet; if this is the case, connect the drain fitting to a hose that runs to a drain or sink. Do not activate the DRAIN
function until you have a place to drain the water with a hose to a sink or drain, observing all municipal codes. Used water from the
cabinet is not potable.
2.
Remove the bottom drawer(s)
3.
From the HOME screen, press SETUP
4.
In the SETUP screen, press SET RESERVOIR
5.
Press DRAIN. The next screen that appears will ask if you are sure. Double check that the cabinet is hooked up to a drain. Otherwise it
will drain onto your floor! If you are not sure, press no and double check. If you are sure, press YES.
6.
The cabinet will start to drain the reservoir. This may take up to 20 minutes. Once the reservoir has been drained, wipe off any dirt
with a clean rag.
7.
Add your preferred cleaning solution (i.e. hydrogen peroxide mixture) into the reservoir. Follow the guidelines on the label of the
agent. The capacity of the GCV12 is 3.25 gallons. H
2
O
2
concentration should be 5 tsp per one gallon of water.
8.
From the HOME screen, press SET RESERVOIR, then FILL. Filling should take approximately 20 minutes.
9.
When the reservoir has refilled, from the HOME screen press ZONE 1 and then WATER NOW so that the cleaning solution flows through
the cabinet’s piping system to ZONE 1
10. Repeat step 9 for ZONE 2
11. Once the zones and reservoir are cleaned, from the HOME screen, press SETUP, SET RESERVOIR, then RECYCLE. This will drain the reser-
voir of the cleaning solution and then refill it with fresh water for your next growing cycle.