Viking GBQ1363 Скачать руководство пользователя страница 2

IMPORTANT

3

Please Read and Follow

Table of Contents

• Before beginning, please read these instructions

completely and carefully.

• Do not remove permanently affixed labels,

warnings, or plates from product. This may void
the warranty. 

• Please observe all local and national codes and

ordinances.

• The installer should leave these instructions with

the consumer who should retain for local
inspector’s use and for future reference.

• This outdoor cooking appliance shall be only

used outdoors and shall not be used in a
building, garage or any other enclosed area.

Installation must conform with local codes 
or in the absence of codes, the National Fuel Gas
Code, ANSI Z223.1/NFPA 54.  

In Canada: Installation must be in accordance with
the current CSA-B149.1, Natural Gas and Propane
Installation Code or CSA-B149.2, Propane Storage
and Handling Code and/or local codes. For units
with an external electrical source, when installed,
must be electrically grounded in accordance with
local codes or with the National Electrical code
ANSI/NFPA 70, or Canadian Electrical code, CSA
C22.1. 

IMPORTANT–

Please Read and Follow

WARNING

EXCESSIVE WEIGHT HAZARD

Use two or more people to move and install this
unit. Failure to follow this instruction can result
in back or other injury.

FOR YOUR SAFETY

If not installed, operated and maintained in 
accordance with the manufacturer’s instructions,
this product could expose you to substances in
fuel or fuel combustion which can cause death
or serious illness and which are known to cause
cancer, birth defects or other reproductive harm.

For example, benzene is a chemical which is
part of the gas supplied to the cooking product. 
It is consu-incomplete combustion. Properly
adjusted burners with a bluish rather than yellow
flame minimize incomplete combustion.

WARNING

This outdoor gas grill is not intended to be
installed inside a home or on recreational
vehicles and/or boats. 

WARNING

Keep electrical supply cord and the fuel supply
hose away from heated surfaces.  

WARNING

This appliance is not fused. Installer must install
a ground fault interrupt. 

CAUTION

Conversions should only be performed by an
authorized service technician.

WARNING

ELECTRICAL SHOCK HAZARD

This appliance is equipped with a 3’ (91.4 cm) 
3-prong power cord with a grounding plug for
your protection against shock hazard and should
be plugged directly into a properly grounded
receptacle. Do not cut or remove the grounding
prong from this plug. This unit is not fused and
installer must install a GFI. Unit must be
grounded in accordance with local codes or with
the National Electrical Code ANSI/NFPA 70, or
the Canadian Electrical Code, CSA C22.1.

CAUTION

Before placing into operation, always check for
gas leaks with a soapy water solution. 

DO NOT

USE AN OPEN FLAME TO CHECK FOR LEAKS.

DANGER

WHAT TO DO IF YOU SMELL GAS:
• Shut off gas to the appliance. 
• Extinguish any open flame. 
• Open lid. 
• If odor continues, keep away from the

appliance, immediately call your gas supplier
or your fire 

department.

FOR YOUR SAFETY

• DO NOT 

store or use gasoline or other

flammable vapors and liquids in the vicinity of
this or any other appliance. 

• Any LP cylinder not connected for use shall 

not be stored in the vicinity of this or any other
appliance. 

Important Safety Instructions __________________________________________________________2
Dimensions (30" & 36" 100 and 300 Series)_____________________________________________4
Specifications (30" & 36" 100 and 300 Series)___________________________________________5
Dimensions (30" & 42" 500 Series Grills) _______________________________________________6
Specifications (30" & 42" 500 Series Grills) _____________________________________________7
Dimensions (54" 500 Series Grill) ______________________________________________________8
Specifications (54" 500 Series Grill) ____________________________________________________9
General Information ________________________________________________________________10
Clearance Dimensions (100 and 300 Series)____________________________________________12
Clearance Dimensions (500 Series)____________________________________________________14
Cutout Dimensions (100 and 300 Series) ______________________________________________17
Cutout Dimensions (500 Series) ______________________________________________________19
Ventilation for Built-In Installations ____________________________________________________22
Gas and Electrical Connection _______________________________________________________23
Natural Fixed Piping Connection _____________________________________________________24
LP/Propane Fixed Piping Connection _________________________________________________25

Built-In Installations _____________________________________________________________26

LP/Propane Tank Requirements ______________________________________________________26
LP/Propane Tank Connection ________________________________________________________27
Leak Testing  _______________________________________________________________________28
Burner Adjustment__________________________________________________________________30
Rotisserie System ___________________________________________________________________32
Final Preparation ___________________________________________________________________33
Performance Checklist ______________________________________________________________33
Service & Registration _______________________________________________________________34

2

Содержание GBQ1363

Страница 1: ...Viking Range Corporation 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com F20896C EN 0...

Страница 2: ...ian Electrical Code CSA C22 1 CAUTION Before placing into operation always check for gas leaks with a soapy water solution DO NOT USE AN OPEN FLAME TO CHECK FOR LEAKS DANGER WHAT TO DO IF YOU SMELL GA...

Страница 3: ...r assembly for connection to standard 5gal 20 lb LP Propane gas cylinder with Type 1 QCC 1 connection or standard residential 1 2 1 3 cm ID gas service line Electrical requirements 100 Series Models 9...

Страница 4: ...uirements 120VAC 60HZ 3 91 4 cm power cord supply cord with 3 prong grounded plug attached to grill 120VAC 60HZ 2 61 0 cm power cord supply cord with 3 prong grounded plug attached to rotisserie motor...

Страница 5: ...l 1 2 1 3 cm ID gas service line Electrical requirements 120VAC 60HZ 3 91 4 cm power cord supply cord with 3 prong grounded plug attached to grill 120VAC 60HZ 2 61 0 cm power cord supply cord with 3 p...

Страница 6: ...for the ignition system and canopy lights In addition the rotisserie motor requires a separate 110 120 volt supply to be located on the right hand side of the grill Both the power supply cords for the...

Страница 7: ...ustable surface 6 15 2 cm Clearance Dimensions 100 and 300 Series 36 W Grill 13 22 15 16 58 3 cm 17 3 16 43 7 cm 10 5 8 26 9 cm 27 9 16 70 0 cm 8 20 3 cm 5 3 8 13 7 cm 27 13 16 70 6 cm 29 73 6 cm 3 mi...

Страница 8: ...cm to combustable surface 6 15 2 cm VGBQ54203RE VGIQ54203RE 15 14 22 15 16 58 3 cm 16 5 8 80 2 cm 10 1 4 26 0 cm 29 1 2 74 9 cm 8 20 3 cm 5 3 8 13 7 cm 32 3 4 83 2 cm 31 9 16 80 2 cm 3 min 7 6 cm to...

Страница 9: ...on 300 Series to be located on rear wall with a maximum distance of 2 61 0 cm beneath solid bottom support S o l i d b o t t o m s u p p o r t Countertop typically requires 3 4 wide by 3 4 deep notch...

Страница 10: ...olid bottom to support the full weight of the unit Cutout Dimensions 500 Series 30 W Grill 19 10 1 8 25 7 cm 36 91 4 cm Access door opening 24 3 8 61 9 cm 35 1 4 89 5cm 3 7 6 cm min Electrical connect...

Страница 11: ...trical connection for rotisserie motor position unit so that the plug is always accessible Electrical connection for power supply cord on 500 Series to be located on rear wall with a maximum distance...

Страница 12: ...an 1 00 inch from inside floor of installation Vents located on sidewall Ventilation for Built In Installations An enclosure for an LP gas cylinder shall be ventilated by openings at both the upper an...

Страница 13: ...r Assembly Natural Fixed Piping Connection Check with your local gas utility company or with local codes for instructions on installing gas supply lines Be sure to check on type and size of run and ho...

Страница 14: ...ed The LP Propane tank should be a standard 5 gal 20 lb gas cylinder tank approximately 12 in diameter and 18 high which must be constructed and marked in accordance with the Specifications for LP Pro...

Страница 15: ...one part liquid detergent and one part water You will need a spray bottle brush or towel to apply the solution to the fittings Note For LP Propane units check with a full cylinder Check that all contr...

Страница 16: ...s following Must push ignition button on 100 Series Note By replacing the knob it may be easier to light the burner A qualified installer should perform the following burner adjustments Each burner is...

Страница 17: ...ed skewer bushing should rest on the left side bracket Do not remove the plastic cover on the rotisserie motor switch due to safety consideration 32 WARNING ELECTRICAL SHOCK HAZARD This appliance is e...

Страница 18: ...underneath the pullout drip tray on the left hand side Model number ____________________________________________________________________________________ Serial number ________________________________...

Отзывы: