Disassembly
©2012 Viking Preferred Service
15
WARNING
!
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless
test procedures require power to be connected. Ensure all ground wires are connected before certifying unit as
repaired and/or operational.
3. Reverse procedure to reinstall
To check low voltage board, refer to chart on
2. Compress plastic standoffs securing low
voltage board, disconnect wiring and
remove.
1. To access the low voltage board, remove
the upper air grill assembly, control panel
(see Air Grill and Control Panel Removal
The unit uses a control board in conjunction
with an overlay switch to operate functions
of the refrigerator/freezer. Interaction with
the low voltage board is via the ribbon cable
attached to the overlay switch.
Low Voltage Board
Overlay Switch (continued)
3. Peel overlay off control panel and remove
(remove adhesive to ensure replacement
overlay adheres properly)
4. Reverse procedure to reinstall.
High Voltage Board
A control board is used to operate functions
of the unit. Once an input is received from
the low voltage board, the high voltage board
sends an output to activate the components.
1. To access the high voltage board, remove
the upper air grill assembly, and control
panel (see Air Grill and Control Panel
2. Compress plastic standoffs securing the
high voltage board and pull towards you.
High voltage board is now accessible.
To check high voltage board, refer to
3. Reverse procedure to reinstall.
LV Board
HV Board