Disassembly
©2012 Viking Preferred Service
17
WARNING
!
Condenser Fan
1. To access the condenser fan assembly,
remove upper air grill assembly, remove
control panel assembly (see Air Grill and
Control Panel Removal sections, Page
2. Remove the control box in order to gain
easy access to the door hinge area for
service. There are 4 ¼” hex screws (2
on each side) holding the control box to
the refrigerator housing. Remove these
screws.
3. Unplug the 15-pin Molex power plug, as
well as the 2-wire converter frequency
cable and the 3-wire thermistor plug .
Remove electronics box and set aside to
gain access to condenser fan assembly.
4. Remove the three 1/4" hex screws
holding fan assembly in place, remove
fan assembly
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless
test procedures require power to be connected. Ensure all ground wires are connected before certifying unit as
repaired and/or operational.
Inverter (continued)
4. The inverter is now accessible on the right
side.
Inverter
120 VAC is supplied to the inverter
from E4 on the High Voltage Board.
The LV board sends 5 VDC to the
inverter to operate the compressor.
5. Reverse procedure to reinstall.
Condenser Fan
The condenser fan is located in the upper
machine compartment of the unit. 120 VDC
is supplied to the fan when the Compressor/
Condenser Fan relay closes to E4 on the
High Voltage Board.