Service Procedures
©2012 Viking Preferred Service
37
FRZ
TEMP
HIGHER
LOWER
REF
TEMP
ALARM
OFF
HIGHER
MAX
FRZ
HIGHER
LOWER
LOWER
MAX
FRZ
While in Mode C, press and
release, either "FRZ TEMP or
REF TEMP" to display the current
model type setting, a three digit
number in the display.
Pressing and releasing either
"HIGHER or LOWER" pads will
allow you to change model types
until you get to the proper three
digit number for your unit, see
Table 1 on Page 42 . The correct
type number for this unit is 136.
The "REFRIGERATOR and/or FREEZER"
indicators will illuminate for each model type
as it is selected depending upon the model
configuration. (example: code 430 will only
illuminate the "REFRIGERATOR" indicator
because it is an All Refrigerator)
If you are not already in Mode B, go back to
Mode B instructions on Page 33.
Once you are in Mode B (Prb in display),
press and hold "ALARM OFF" for
three seconds and display will
change to "PrC", signifying that
control is now in Program Mode
C, see illustration below.
Program Mode C
Set Model type
Setting the model code is required
whenever the low voltage board is
replaced, this will update all of the settings
indicated in Table 1 on Page 42 for the
model you select. With this setting you can
program all necessary settings with one
input for the appliance.
Adjust Freezer Upper Temperature Limit
While in Mode C, press and hold
"MAX FRZ" and and then hold the
"HIGHER" pad for three seconds,
this will result in the display
changing to "FUL".
Pressing and releasing "HIGHER
and LOWER" pads will increase
or decrease the set point, which
should be set at 7
o
F.
Adjust Freezer Lower Temperature Limit
While in Mode C, press and hold
"MAX FRZ" and and then hold the
"LOWER" pad for three seconds,
this will result in the display
changing to "FLL".