background image

Viking Range Corporation

111 Front Street

Greenwood, Mississippi 38930 USA

(662) 455-1200

For product information,

call 1-888-VIKING1 (845-4641)

or visit the Viking Web site at

vikingrange.com

F20533 EN

(093008J)

®

Viking Installation Guide

Professional Freestanding Dual Fuel Ranges

Содержание F20533

Страница 1: ...reet Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com F20533 EN 093008J Viking Installation Guide Profes...

Страница 2: ...klist ______________________________________________________________________26 Service Registration ______________________________________________________________________27 Before beginning please rea...

Страница 3: ...call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qua...

Страница 4: ...7 8 91 1 cm 47 7 8 121 6 cm 60 152 4 cm Note Unit shown with standard island trim Note Unit shown with standard island trim Dual Fuel 30 36 48 and 60 W Ranges 25 3 4 65 4 cm 45 1 8 114 6 cm 19 3 8 49...

Страница 5: ...o top of high shelf add 23 1 2 59 7 cm Gas Requirements Shipped Natural or LP Propane field convert with conversion kit purchased separately accepts standard residential 1 2 1 3 cm ID gas service line...

Страница 6: ...of a standard hood should be 30 76 2 cm min to 36 91 4 cm max above the countertop This would typically result in the bottom of the hood being 66 167 6 cm to 72 182 9 cm above the floor Refer to the r...

Страница 7: ...this manual before work begins Pressure Regulator All heavy duty commercial type cooking equipment must have a pressure regulator on the incoming service line for safe and efficient operation since s...

Страница 8: ...ti tip Device Installation section Some stainless steel parts may have a plastic protective wrap which must be peeled off The interior should be washed thoroughly with hot soapy water to remove film r...

Страница 9: ...h grounding product to the frame of the unit may or may not be permitted through your local codes If ground to the frame is not permitted then a 4 conductor power cord must be used WARNING Electrical...

Страница 10: ...of codes with the National Electrical Code NEC ANSI NFPA 70 latest edition Use a 4 wire power supply cord kit rated for 40 amps 125 250 volts with closed loop terminals and marked for use with ranges...

Страница 11: ...side and front to back Side trim of the high corner must be 3 8 0 95 cm above countertop If leveling is required move unit out of opening 6 1 2 1 Lift unit and prop on wood blocks 4 Feed supply cord...

Страница 12: ...alified licensed plumber or gas service company Leveling Adjustments Alignments cont Connecting Gas Electric WARNING Tipping hazard To reduce the risk of property damage or personal injury install ant...

Страница 13: ...d trim Attach with four screws provided 2 3 Burner caps are packed in styrofoam top pack with the grates Place burner on top of range Place burner grate on top of burner cap and grate support Note Arr...

Страница 14: ...See drawing for proper flame height on HI The low flame should light at every port h Check oven bake function bake element on full power center and outside broil elements at partial power h Convectio...

Страница 15: ..._ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ Notes _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __...

Страница 16: ...31 30...

Отзывы: