background image

13

FINAL PREPARATION

1.  Some stainless steel parts may have a plastic protective wrap which must be peeled off.  The interior of the

refrigerated beverage center should be washed thoroughly with hot, soapy water, rinsed and wiped dry to remove
film residue and any installation dust or debris before being used.  Solutions stronger than soap and water are rarely
needed.

2.  All stainless steel parts should be wiped with hot soapy water.  If buildup occurs, do not use steel wool, abrasive

cloths, cleaners, or powders.  If it is necessary to scrape stainless steel to remove encrusted materials, soak with hot,
wet cloths to loosen the material, then use a wood or nylon scraper.  Do not use a metal knife, spatula, or any other
metal tool to scrape stainless steel; scratches are almost impossible to remove.

12

ELECTRICAL CONNECTION

E

Elle

eccttrriicca

all  R

Re

eq

qu

uiirre

em

me

en

nttss

A  115  volt,  60  Hz,  AC  only  15  amp  fused  electrical  supply  is
required.  (A time delay fuse or circuit breaker is recommended.)  It
is recommended that a separate circuit, serving only this appliance,
be provided.  

•E

EL

LE

EC

CT

TR

RIIC

CA

AL

L  G

GR

RO

OU

UN

ND

D  IIS

S  R

RE

EQ

QU

UIIR

RE

ED

D  O

ON

N  T

TH

HIIS

S  A

AP

PP

PL

LIIA

AN

NC

CE

E..    

•D

DO

O  N

NO

OT

T  U

UN

ND

DE

ER

R  A

AN

NY

Y  C

CIIR

RC

CU

UM

MS

ST

TA

AN

NC

CE

ES

S  R

RE

EM

MO

OV

VE

E  T

TH

HE

E  P

PO

OW

WE

ER

R

S

SU

UP

PP

PL

LY

Y  C

CO

OR

RD

D  G

GR

RO

OU

UN

ND

D  P

PL

LU

UG

G..

•D

DO

O  N

NO

OT

T  U

US

SE

E  A

AN

N  E

EX

XT

TE

EN

NS

SIIO

ON

N  C

CO

OR

RD

D

R

Re

ecco

om

mm

me

en

nd

de

ed

d  G

Grro

ou

un

nd

diin

ng

g  M

Me

etth

ho

od

dss

For your personal safety, this refrigerated beverage center  must be grounded. This appliance is equipped with a 7’ (2.1
m) power supply cord having a 3-prong grounding plug. To minimize possible shock hazard, the cord must be plugged
into a mating 3-prong grounding type wall receptacle grounded in accordance with the National Electrical Code and local
codes and ordinances. If the circuit does not have a grounding type receptacle, it is the responsibility and obligation of
the customer to exchange the existing receptacle in accordance with the National Electrical Code and applicable local
codes and ordinances. The third ground plug SHOULD NOT, under any circumstances, be cut or removed.  All UL listed
refrigerated beverage centers are equipped with this type of plug.

Power Supply with

3-prong grounding

plug

Grounding type wall
receptacle

LIGHT BULB REPLACEMENT - 24” W. Models

This unit uses a 15-watt incandescent bulb located behind the display housing.

To replace the light bulb:
1. Unscrew the old light bulb located behind the display housing.
2. Discard the old light bulb.
3. Screw new light bulb into location behind the display housing.

E

EN

NE

ER

RG

GY

Y  S

SA

AV

VIIN

NG

G  T

TIIP

PS

S

•Reduce door openings.
•Close the door as soon as you can.
•Keep the condenser coils on bottom of the refrigerated beverage center clean.  (See “Cleaning and Maintenance”.)
•Adjust the temperature control to a warmer setting when practical.
•Do not put hot foods in the refrigerated beverage center.
•Install unit away from the stove or other heat sources.

LIGHT ASSEMBLY REPLACEMENT - 15” W. Models

NOTE

:

Please  contact  your  Viking  Range

Corporation  parts  distributor  or  dealer  to  order
new light assembly.

To  replace  the  light,  first  disconnect  the
refrigerated beverage center’s power cord.  Next,
remove both the green ground wire screw located
on  the  left  of  the  light  assembly  and  the  other
screw  located  on  the  right  of  the  light  assembly
with a 5-16” hex head screwdriver.  (See drawing).
Unplug  the  light  unit  and  remove  complete  light
assembly.  

To  install  the  new  light  assembly,  screw  in  the
green ground wire screw and the screw located on
the  right  with  a  5/16”  hex  head  screwdriver  and
plug the light unit in.

Plug

Hex head
screw

Light
assembly

Green
ground wire

Hex head

screw

ELECTRICAL SHOCK HAZARD

Failure to follow these instructions could result in fire or electrical shock.

WARNING

ELECTRICAL SHOCK HAZARD

Failure to follow these instructions could result in fire or electrical shock.

WARNING

ELECTRICAL SHOCK HAZARD

Failure to follow these instructions could result in fire or electrical shock.

WARNING

LEG LEVELER INSTALLATION

R

Re

ea

ad

d  B

Be

effo

orre

e  IIn

nsstta

alllliin

ng

g  L

Le

eg

g  L

Le

evve

elle

errss

1.  Four leveling legs are pre-installed in the base of the unit at the factory.

2.  The unit should be leveled from front to back and side to side. If floor

conditions do not allow the unit to sit level, adjust the leg levelers by turning
the required leg leveler counter-clockwise to increase the height and clockwise
to reduce the height.

WARNING

Do not lay unit on top, side, back, or front.  If unit is accidentally laid in
any position other than right side up, then the unit must remain in the
upright position for at least 24 hours before plugging the unit in.

Содержание F20497

Страница 1: ...ration 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKNG1 845 4641 or visit the Viking Web Site at vikingrange com Viking Use Installation Guide Undercounter Freestanding Refrigerated Beverage Centers ...

Страница 2: ... FROM THE ELEMENTS SUCH AS WIND RAIN WATER SPRAY OR DRIP 1 Place unit so the front side will be completely unobstructed to provide proper air flow The unit may be closed in on the top and three sides but the front M MU US ST T B BE E unobstructed for air circulation and proper operation Installation should be such that the cabinet can be moved for servicing if necessary 2 Unit should be in a well ...

Страница 3: ...Approximate Shipping Weight 110 lbs 49 5 kg Front View Side View 30 3 4 78 1 cm Min 34 1 4 87 0 cm to Max 35 88 9 cm with leveling legs fully extended 14 3 4 37 5 cm 21 3 16 53 8 cm 23 5 8 60 0 cm 26 1 8 66 4 cm 37 3 16 94 5 cm Front View Side View DUAR Side View DFUR 30 3 4 78 1 cm Min 34 1 4 87 0 cm Max 35 88 9 cm with leveling legs fully extended 14 3 4 37 5 cm 21 3 16 53 8 cm 23 5 8 60 0 cm 26...

Страница 4: ...ps 3 3 Approximate Shipping Weight 140 lbs 63 2 kg Min 34 1 4 87 0 cm to Max 35 88 9 cm with leveling legs fully extended 30 3 4 78 1 cm 23 7 8 60 6 cm 47 1 4 120 0 cm 22 55 9 cm 24 3 8 61 9 cm 26 7 8 68 3 cm Front View Side View Front View 30 3 4 78 1 cm Min 34 1 4 87 0 cm Max 35 88 9 cm with leveling legs fully extended 23 7 8 60 6 cm Side View DUAR 22 55 9 cm 24 3 8 61 9 cm 26 7 8 68 3 cm 47 1 ...

Страница 5: ...de by loosening the door hinge machine screws and moving the door hinge brackets on the door 4 Tighten all four 4 machine screws after adjustments have been made 5 Remove the door from the unit by removing the units top hinge set screw and angling the door off of the bottom hinge pin Figure 1 Shoulder Bushing Door Hinge Bracket 10 32 Machine Screw Door Hinge Screw Holes Door Front Surface T Ty yp ...

Страница 6: ...ttached wood frame 3 8 clearance holes for frame wood screws 10 holes Door hinge adjustment screws Attaching the Handle Attach the handle of your choice by drilling mounting holes through panel Countersink or counterbore holes from back side of panel for handle screw heads to be flush CAUTION Door can become disengaged if washers are not installed CAUTION Door can become disengaged if washers are ...

Страница 7: ...with this type of plug Power Supply with 3 prong grounding plug Grounding type wall receptacle LIGHT BULB REPLACEMENT 24 W Models This unit uses a 15 watt incandescent bulb located behind the display housing To replace the light bulb 1 Unscrew the old light bulb located behind the display housing 2 Discard the old light bulb 3 Screw new light bulb into location behind the display housing E EN NE E...

Страница 8: ...o or r y yo ou u m ma ay y e ex xi it t S SE ET T m mo od de e b by y p pr re es ss si in ng g t th he e k ke ey yp pa ad d a a s se ec co on nd d t ti im me e T Te em mp pe er ra at tu ur re e v va ar ri ia at ti io on n i in n c co om mp pa ar rt tm me en nt t a ai ir r a ab bo ov ve e a an nd d b be el lo ow w s se et t p po oi in nt t i is s a a n no or rm ma al l e ef ff fe ec ct t o of f r r...

Страница 9: ...he wine shelf creates the separate temperature area Do not remove if storing wine 15 W Wine Shelf 24 W Wine Shelf Odor in cabinet Unit interior needs cleaning Clean inside of unit Noisy operation Unit not level Adjust leveling legs Unit vibrates Unit not level Adjust leveling legs Weak floor Rebuild floor or move to a different location Interior lighting not working Light burned out Replace light ...

Страница 10: ...i il ll l d di is sa ab bl le e t th he e r re ef fr ri ig ge er ra at to or r s sy ys st te em m a an nd d f fa an ns s w wh hi il le e a al ll lo ow wi in ng g t th he e i in nt te er rn na al l l li ig gh ht ts s d di is sp pl la ay y a an nd d u us se er r i in nt te er rf fa ac ce e p pa an ne el l t to o f fu un nc ct ti io on n L Li ig gh ht ts s w wi il ll l t ti im me e o ou ut t a af ft ...

Страница 11: ... component parts contains a defect or malfunction during the warranty period after a reasonable number of attempts by the warrantor to remedy the defects or malfunctions the owner is entitled to either a refund or replacement of the product or its component part or parts Replacement of a component part includes its free installation Warrantor s liability on any claim of any kind with respect to th...

Страница 12: ...hall not apply to damage resulting from abuse accident natural disaster loss of electrical power to the product for any reason alteration improper installation improper operation or repair or service to the product by anyone other than an authorized Viking Range Corporation service agency or representative Warranty shall not apply to damage resulting from indoor units being used in outdoor situati...

Отзывы: