background image

10

   

B. One or two Viking E-70 Entry Phones Sharing a Single Phone Line with Optional
Call Forwarding, Keyless Entry and Doorstrike/Gate Control

13.8V AC

Adapter

included

Standard

Analog Phone(s)

OR

Analog Trunk / Line Input

of a Phone System

C.O. / Phone

Line Input

VIKING

©

VIKING

ELECTRONICS

HUDSON, WI 54016

ADVANCED 2 DOOR ENTRY PHONE

CONTROLLER WITH CALL FORWARDING

POWER 13.8V AC

MODEL C-500

PHONE LINE

INPUT

LINE OUT

T

O

 PHONES

1

2 3

4

ENTR

Y

PHONE 1

5

6

7

8

9

DOOR

STRIKE 1  

N.C. 

N.O. 

COM

ENTR

Y

PHONE 2

13 14

SLP

CONTROL

18

+

19

TRIGGER

INPUT 1

10 11 12

TRIGGER

INPUT 2

15 16 17

DOOR

STRIKE 2  

N.C. 

N.O. 

COM

5A@30VDC/ 
250VAC max

(Power typically 

not required for

gate controllers)

 Door Strike / 

Magnetic Lock 2

120V AC

Entry Phone 2

E-70-SS shown

Dip switch 3

to OFF

Contol Output to

 SLP-1 or SLP-4

5A@30VDC/ 250VAC max

(Power typically not required 

for gate controllers)

 Door Strike / 

Magnetic Lock 1

120V AC

Entry Phone 1

E-70-BN shown

120V AC

R

E

X

1

R

E

X

2

D

Model C-500 (not included)

For more information on
the C-500, see DOD# 177.

Содержание E-70-BK

Страница 1: ...unique front and back door chimes and paging when used with a Viking SLP 1 SLP 4 and C 2000B Residential commercial and industrial door security Use with a Viking K 1900 5 or K 1900 30 for automatic s...

Страница 2: ...ABLOY company All other trademarks are the property of their respective owners AWID is a trademark of Applied Wireless Identification Group Faceplate Gasket 1 8 thick closed cell PVC to provide a wate...

Страница 3: ...an cause plate misalignment and compromise the gasket seal Step 4 The front surface of the Rough In box can be mounted flush against wood siding or can be recessed and mounted flush against wall sheat...

Страница 4: ...ad Screws included Old Work Double Gang Rough In Box with minimum dimensions of 3 65 W x 2 84 H x 2 25 D Carlon BH234R box shown not included Optional VE 5x5 Surface Mount Box with Black Satin Powder...

Страница 5: ...64 LED3 LED1 LED2 LED4 LED5 LED6 LED7 C C C C C C C J11 1 2 3 J10 1 2 3 J9 1 2 3 J8 1 2 3 J7 1 2 3 1 2 3 on 4 5 VIKING MODEL C 2000B VIKING ELECTRONICS HUDSON WI 54016 ADVANCED DOOR GATE AND ENTRY PHO...

Страница 6: ...ial St Hudson WI 54016 P N DEV Complies with FCC Part 15 and 68 Reg No US AH3TE08A22264 Back View of the E 70 Circuit Board Mounting Plate Black GND Red 5 14VDC Green Date 0 White Data 1 Up to 500 ft...

Страница 7: ...ection DIP switch 2 OFF With DIP switch 3 in the OFF position the E 70 is in the Normal Operation Mode factory setting By placing DIP switch 3 in the ON position the E 70 s programming mode is enabled...

Страница 8: ...H Silence Time Out G Call Length Time Out This feature selects the maximum length of time that calls can be connected Programmable in increments of 1 minute up to a maximum of 9 minutes To disable the...

Страница 9: ...RIKE 4 DOORBELL SWITCH AUX INPUT AUX CONTACT OUTPUT PHONE LINE INPUT LINE OUT TO PHONES ANALOG STATION INPUT Entry Phone 1 E 65 SS shown Example Front Door C O Phone Line Input To Standard Analog Touc...

Страница 10: ...NE OUT TO PHONES 1 2 3 4 ENTRY PHONE 1 5 6 7 8 9 DOOR STRIKE 1 N C N O COM ENTRY PHONE 2 13 14 SLP CONTROL 18 19 TRIGGER INPUT 1 10 11 12 TRIGGER INPUT 2 15 16 17 DOOR STRIKE 2 N C N O COM 5A 30VDC 25...

Страница 11: ...PHONE N O COM N C AUX CONTACTS ON 1 2 3 AUX POWER OUTPUT VIKING POWER 13 8V AC VIKING ELECTRONICS HUDSON WI 54016 SINGLE ENTRY PHONE CONTROLLER MODEL C 200 RING COUNT 1 EARTH GND 1 RELAY MODE 2 DOORB...

Страница 12: ...LE OR USE OF THE PRODUCT SOLD HEREUNDER EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY WHETHER IN AN ACTION BASED ON CONTRACT TORT INCLUDING NEGLIGENCE OR STRICT LIABILITY OR ANY OTHER LEGAL THEORY ANY...