![Viking E-65-SS Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/viking/e-65-ss/e-65-ss_technical-manual_1024539006.webp)
6
P
P
r
r
o
o
g
g
r
r
a
a
m
m
m
m
i
i
n
n
g
g
A. Adjusting Speaker Volume
B. Adjusting the Microphone Volume
In certain noisy locations (background traffic,
machinery or wind), the microphone volume
may need to be decreased. A symptom of
this is one-way talk path, in which the distant
party cannot be heard over the speaker. A
microphone volume pot is provided for
increasing or decreasing the microphone vol-
ume.
Note:
If the microphone volume is set
too high or too low, one-way talk path may
occur.
The speaker volume pot can be adjusted to
increase or decrease the speaker volume to
the level desired.
VIKING
Model:
XXXXXXX
xxxxxx
S/N:
REN 0.8A:
XXXXXXXX
V
iking Electronics, Inc. (715) 386-8861
1531 Industrial St., Hudson, WI 54016
P/N:
DEV
:
Complies with FCC Part 15 and 68 Reg. No: US:AH3TE08A22264
Rear View of the
E-65 Circuit Board
Mounting Plate
Speaker
Volume
(see section A)
Microphone
Volume
(see section B)
1 2 3 4
ON
DIP
Switches
ON
OFF
Note:
Pots and DIP switches are shown in factory default settings.
C. DIP Switch Programming
DIP switch 1 is for turning the Auto Answer feature ON and OFF.
The
E-65
is factory set to auto answer when an inbound call is
detected.
1. Auto Answer Feature ON/OFF (DIP Switch 1)
With DIP switch 2 in the ON position, if the
E-65
detects more
than 5 seconds of continued dial tone, the unit will automatically
disconnect. If the
E-65
is installed on a continuously noisy line, it
may detect the noise as dial tone and automatically disconnect. If
this happens, turn the dial tone detection (DIP switch 2) OFF.
2. Dial Tone Detection ON/OFF (DIP Switch 2)
With DIP switch 3 in the OFF position, the
E-65
is in the “Normal Operation Mode” (factory setting). By placing DIP
switch 3 in the ON position, the
E-65
’s programming mode is enabled. The programming mode is used for adjust-
ing the Call Length Time Out, Silence Time for automatic disconnect and the Talk/Listen delay (VOX switching
speed). These features are set from the factory and normally do not need adjustment. If adjustment is necessary,
see
Programming
sections
D - I
.
3. Programming Mode ON/OFF (DIP Switch 3)
Switch
1
1
2
2
3
3
4
4
Position
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Description
Auto-Answer ON *
Auto-Answer OFF
Dial Tone Detection ON *
Dial Tone Detection OFF
Programming Mode
Normal Operation Mode *
LED On *
LED Off
With DIP switch 4 in the ON postion, the blue faceplate LED will remain on at all times (to help locate push button
switch in dark locations), dim to indicate off hook and flash to indicate incoming ring. When connecting an
E-65
to
a C.O.line, turn the LED off to comply with FCC regulations.
4. LED On/Off (DIP Switch 4)
* Note: