Viking E-1600-20A-EWP Скачать руководство пользователя страница 2

Installation

IMPORTANT:

Electronic devices are susceptible to lightning and power station electrical surges from both the AC

outlet and the telephone line.  It is recommended that a surge protector be installed to protect against such surges. 

Step 1

When using the power terminals, make sure your product is listed in 

Diagram 1

. If your product is not

listed please see section 

B

below and wire using the included power supply.

Step 2

Disconnect power from the doorbox or phone.

Step 3

Remove the doorbox or phone from the surface mount box.

Step 4

Connect the two wires from the 

VE-LIGHT

to the power input terminals of the doorbox (see 

Diagram

2

).  

Note: 

Wires can be connected in either polarity.

Step 5

Place the 

VE-LIGHT

bracket against the upper mounting lip of the surface mount box and route wires

through the provided slot (see 

Diagram 2

).

Step 6

Carefully place the phone or doorbox back into the surface mount box, making sure the wires stay in
the slot (see 

Diagram 5

).

B. Using the Included Power Supply (see Diagram 3)

A.  Using the Power Input Terminals of a Viking Doorbox

Diagram 1

Viking Model

DOD#

K-1200/EWP

182

K-1205/EWP

183

W-1000/EWP

170

W-3000/EWP

180

W-3005/EWP

181

Viking Model

DOD#

E-10A/EWP

210

E-30/EWP

212

E-30-PT/EWP

214

E-35/EWP

178

E-1600-20A/EWP

215

E-1600-30A/EWP

215

E-1600A-BLT-EWP

217

E-1600A-BLT2-EWP

217

K-1500-7

352

K-1700-3/EWP

157

K-1705-3/EWP

159

K-1900-7/EWP

364

K-1900-8/EWP

362

Diagram 3

Step 1

Disconnect power from the doorbox or phone.

Step 2

Remove the doorbox or phone from the surface mount box.

Step 3

Connect the two wires from the 

VE-LIGHT

to the included power supply using the included butt con-

nectors (see 

Diagram 4

).  

Note: 

Wires can be connected in either polarity.

Step 4

Place the 

VE-LIGHT

bracket against the upper mounting lip of the surface mount box and route wires

through the provided slot (see 

Diagram 4

).

Step 5

Carefully place the phone or doorbox back into the surface mount box, making sure the wires stay in
the slot (see 

Diagram 5

).

Rear View of Viking Doorbox

(not included)

Not polarity

sensitive

Front View of the VE-LIGHT

IMPORTANT: 

Wires MUST be 

routed through 

the provided slot.

Diagram 2

Front View of the VE-LIGHT

IMPORTANT: 

Wires MUST be 

routed through 

the provided slot.

* (2) Gel-Filled

Butt Connectors

(included)

Not polarity

sensitive

120V AC

12V DC

Adapter

(included)

Negative

Positive

Diagram 4

* Note:  

The gel-filled (water-tight) butt connectors are designed for insu-

lation displacement on 19-26 gauge wire with a maximum insulation of
0.082 inches. Do not strip wires prior to terminating.

2

Содержание E-1600-20A-EWP

Страница 1: ...d from 12 to 24 volts AC or DC Power 120V AC 12V DC 500mA UL listed adapter provided or use any 12 24V AC or DC source 50mA Dimensions 5 x 3 x 1 127mm x 8mm x 25mm Environmental 15 F to 130 F 26 C to 54 C with 5 to 95 non condensing humidity Shipping Weights 1 lb 0 45 kg Maximum Power Run 1000 ft 304m using 24 AWG wire Material 24 gauge Marine Grade 316 stainless steel VE LIGHT Enclosure Lighting ...

Страница 2: ...81 Viking Model DOD E 10A EWP 210 E 30 EWP 212 E 30 PT EWP 214 E 35 EWP 178 E 1600 20A EWP 215 E 1600 30A EWP 215 E 1600A BLT EWP 217 E 1600A BLT2 EWP 217 K 1500 7 352 K 1700 3 EWP 157 K 1705 3 EWP 159 K 1900 7 EWP 364 K 1900 8 EWP 362 Diagram 3 Step 1 Disconnect power from the doorbox or phone Step 2 Remove the doorbox or phone from the surface mount box Step 3 Connect the two wires from the VE L...

Страница 3: ...P E 75 EWP entry phones the E 1600 20A EWP and E 1600 30A EWP emergency phones as well as the W 1000 EWP and W 3000 EWP handsfree doorboxes The VE 6x7 is designed to be used with the K 1700 3 EWP and K 1705 EWP entry phones and the VE 5x10 is designed to be used with the K 1900 7 EWP and the K 1900 8 EWP vandal resistant phones The VE GNP gooseneck pedestals are designed to be used with the VE 5x5...

Страница 4: ...nd troubleshooting a Return Authorization R A number will be issued This number is valid for fourteen 14 calendar days from the date of issue 3 After obtaining the R A number return the approved equipment to your distributor referencing the R A number Your distributor will then replace the Viking product using the same R A number 4 The distributor will NOT exchange this product without first obtai...

Отзывы: