General Information
Electrical Requirement
• A standard 120V/60 Hz, 15 amp circuit,
3-wire ground, 3-prong plug is equipped.
• A minimum of 120 VAC is required for proper
operation of gas ignition systems. The circuit
must be
MUST
be properly grounded and
polarized.
IMPORTANT: It is recommended to have the
electrical wiring and installation of your
cooktop connected by a qualified electrician.
IMPORTANT: The cooktop must be electrically
grounded in accordance with local codes or, in
the absence of local codes, with the National
Electrical Code, ANSI/NFPA 70 latest edition or
Canadian Electrical Code (CSA).
Surface Burners
Initial Ignition of Burners
• All cooktops are tested before leaving the
factory. Field adjustments may be necessary
for proper mixture of gas and air for proper
operation. Contact a qualified technician to
make any necessary adjustments.
• The surface burners use electric igniters in
place of standing pilots.
To ignite electric igniters on the surface burners:
• Turn the knob counterclockwise to any
position.
• Upon ignition of the surface burner, turn the
knob to the desired position (HI, Med or Low).
• To shutdown the burner, turn knob clockwise
to the OFF position.
• In case of failure, shut the gas OFF using the
installer supplied manual shut-off valve.
Site Preparation
Note:
It is recommended that a thorough site
inspection be conducted prior to unpacking and
moving this appliance.
• Confirm available access to adequate power–
see electrical requirements
.
• Be sure that the countertop for this appliance
is level and cut according to the cutout
requirements and dimensions–
see cutout
requirements and dimensions
.
• All wall coverings, countertop and cabinets
around the cooktop should withstand heat up
to 200°F (90° C).
• Keep appliance free from combustible
materials, gasoline, and other flammable
vapors.
Installation Procedure
Remove packaging materials and literature
package from the cooktop before beginning
installation. Remove Installation Instructions
from literature pack and read them carefully
before you begin.
ELECTRICAL SHOCK
HAZARD
Plug into a 3 prong outlet.
DO NOT
remove ground prong.
DO NOT
use an adapter.
DO NOT
use an extension cord.
Failure to follow these instructions can
result in death, fire, or electrical shock.
CAUTION
DO NOT
use an extension cord with this
appliance. Such use may result in fire,
electrical shock or other personal injury
WARNING
14