PROXIMITY TO SIDE CABINETS

1.  The cooktop may be installed directly to existing base cabinets.
2.  The cooktop CANNOT be installed directly adjacent to sidewalls, tall cabinets, tall appliances, or other side vertical

surfaces above 36” (91.4 cm) high.  There must be a minimum of 8” (20.3 cm) side clearance from the cooktop to
such combustible surfaces above the 36” (91.4 cm) counter height.

3.  Within the 8” (20.3 cm) side clearance to combustible vertical surfaces above 36” (91.4 cm), the maximum wall

cabinet depth must be 13” (33.0 cm) and wall cabinets within this 8” (20.3 cm) side clearance must be 18” (45.7 cm)
above the 36” (91.4 cm) high countertop.

4.  Wall cabinet above the cooktop must be a minimum of 36” (91.4 cm) above the countertop for a full width of the

cooktop.  This minimum height requirement does not apply if a rangehood is installed over the cooking surface.

5.  A 120 volt wall receptacle should be located approximately 6” (15.2 cm) below the countertop cutout and 12” 

(30.5 cm) from the right side of the cutout.

MINIMUM CLEARANCES FROM ADJACENT COMBUSTIBLE
CONSTRUCTION

•Above countertop (above 36” [91.4 cm])

•Sides 8” (20.3 cm)
•Rear - See chart dimension “A”
•Within 8” (20.3 cm) side clearance.  Wall cabinets no deeper

than 13” (33.0 cm)

•Must be minimum 18” (45.7 cm) above countertop
•Wall cabinets directly above the product must be minimum

36” (91.4 cm) above the countertop.

4

13” max.
(33.0 cm)

36” min.
(91.4 cm)

18” min.
(45.7 cm)

8” min. 
(20.3 cm)

A

3 1/8”
(7.9 cm)

36” min.
(91.4 cm)

A

VGSU

3 1/2” (8.9 cm) min.

DGCU/DGSU

2 1/2” (6.4 cm) min.

Содержание DGCU105

Страница 1: ...t Front 6 000 Nat LP BTU 6 000 Nat LP BTU 8 000 Nat LP BTU 1 8 Nat LP kw 1 8 Nat LP kw 2 1 Nat LP kw Approximate Shipping Weight 67 lb 30 2 kg 80 lb 36 0 kg 93 lb 41 9 kg DESCRIPTION VGSU102 30 W VGSU162 36 W Cutout Width Minimum 26 7 8 68 3 cm 34 3 8 87 3 cm Maximum 29 7 8 75 9 cm 35 7 8 91 1 cm Cutout Height Minimum 2 1 2 6 4 cm Cutout Depth Minimum 18 5 8 47 3 cm Maximum 20 1 8 51 1cm Overall W...

Страница 2: ...r non vented recirculating hood Nothing should obstruct the flow of combustion and ventilation air 10 Gas Manifold Pressure Natural gas 5 0 W C P LP Propane 10 0 W C P 11 Flexible Connections If the unit is to be installed with flexible couplings and or quick disconnect fittings the installer must use a flexible connector of at least 1 2 I D 1 3 cm NPT with suitable strain reliefs and comply with ...

Страница 3: ...inet above the cooktop must be a minimum of 36 91 4 cm above the countertop for a full width of the cooktop This minimum height requirement does not apply if a rangehood is installed over the cooking surface 5 A 120 volt wall receptacle should be located approximately 6 15 2 cm below the countertop cutout and 12 30 5 cm from the right side of the cutout MINIMUM CLEARANCES FROM ADJACENT COMBUSTIBLE...

Страница 4: ...ve the floor Refer to the rangehood installation instructions for further information These dimensions provide for safe and efficient operation of the hood 30 76 2 cm min 36 91 4 cm max 30 76 2 cm min 36 91 4 cm max 66 72 167 6 cm 182 9 cm 66 72 167 6 cm 182 9 cm 36 92 4 cm ISLAND INSTALLATION WALL INSTALLATION 36 92 4 cm Metal Hood Metal Hood Wood Composite Overlay Wood Composite Overlay Countert...

Страница 5: ...eight Dimension NOTE Minimum cutout height when using a 90o elbow supplied by installer 5 5 8 14 3 cm DGCU CUTOUT DIMENSIONS Cutout Opening 19 3 4 50 2 cm B B M Mi in n M Ma ax x 3 30 0 W W 2 28 8 3 3 4 4 7 73 3 0 0 c cm m 2 29 9 7 7 8 8 7 75 5 9 9 c cm m 3 36 6 W W 3 34 4 1 1 2 2 8 87 7 6 6 c cm m 3 35 5 7 7 8 8 9 91 1 1 1 c cm m 4 45 5 W W 4 42 2 7 7 8 8 1 10 08 8 9 9 c cm m 4 44 4 1 1 8 8 1 11 ...

Страница 6: ...ONS DGSU BURNER BOX DIMENSIONS Electric Cord 48 121 9 cm Gas Inlet 1 1 16 2 7 cm 1 1 16 2 7 cm 3 1 16 7 8 cm 30 W Model 29 1 8 74 0 cm 36 W Model 34 7 8 88 6 cm 19 3 4 50 2 cm C C C C M Mi in n M Ma ax x 3 30 0 W W 29 1 8 74 0 cm 29 7 8 75 9 cm 3 36 6 W W 34 7 8 88 6 cm 35 7 8 91 1 cm ...

Отзывы: