2

DESCRIPTION

DGCU105   (30” W.) 

DGCU165  (36” W.)

DGCU155  (45” w.)

Cutout Width - Minimum 

28 3/4” (73.0 cm)

34 1/2” (87.6 cm)

42 7/8” (108.9 cm)

Maximum

29 7/8” (75.9 cm)

35 7/8” (91.1 cm)

44 1/8” (112.1 cm)

Cutout Height - Minimum

2 3/4” (7.0 cm)

Cutout Depth - Minimum

19 11/16” (50.0 cm)

Maximum

20 1/2” (52.1cm)

Overall Width

30 3/4” (78.1 cm)

36 3/4” (93.3 cm)

45” (114.3 cm)

Overall Height from Bottom 
(including connector)

4 1/4” (10.8 cm)

Overall Depth from Rear

21” (53.3 cm)

Gas Requirements

Not field convertible - Must be ordered from factory either natural or LP/Propane.  

Uses

standard residential 1/2” (1.3 cm) I.D. gas service line.

Electrical Requirements

120 VAC/60 Hz; 4 ft. (121.9 cm), 3-wire cord with grounded 3-prong plug attached to product.

Maximum Amp Usage

2.0 amps

Surface Burner Rating

Left Front-

14,000 Nat./13,500 LP (BTU)

12,000 Nat./11,500 LP (BTU)

12,000 Nat./11,500 LP (BTU)

(4.1 Nat./4.0 LP [kw])

(3.5 Nat./2.8 LP [kw])

(3.5 Nat./2.8 LP [kw])

Left Rear-   

12,000 Nat./11,500 LP (BTU)

10,000 Nat./LP (BTU) 

8,000 Nat./LP (BTU)

(3.5 Nat./2.8 LP [kw])

(2.9 Nat./LP [kw])

(2.1 Nat./LP [kw])

Left Center

N/A

14,000 Nat./13,500 LP (BTU)

10,000 Nat./LP (BTU)

(4.1 Nat./4.0 LP [kw])

(2.9 Nat./LP [kw])

Right Center

N/A

N/A

14,000 Nat./13,500 LP (BTU)

(4.1 Nat./4.0 LP [kw])

Right Rear-   

8,000 Nat./LP (BTU)

8,000 Nat./LP (BTU)

6,000 Nat./LP (BTU)

(2.1 Nat./LP [kw])

(2.1 Nat./LP [kw])

(1.8 Nat./LP [kw])

Right Front-  

6,000 Nat./LP (BTU)

6,000 Nat./LP (BTU)

8,000 Nat./LP (BTU)

(1.8 Nat./LP [kw]) 

(1.8 Nat./LP [kw])

(2.1 Nat./LP [kw])

Approximate Shipping Weight

67 lb. (30.2 kg.)

80 lb. (36.0 kg)

93 lb. (41.9 kg)

DESCRIPTION

VGSU102   (30” W.) 

VGSU162  (36” W.)

Cutout Width - Minimum 

26 7/8” (68.3 cm)

34 3/8” (87.3 cm)

Maximum

29 7/8” (75.9 cm)

35 7/8” (91.1 cm)

Cutout Height - Minimum

2 1/2” (6.4 cm)

Cutout Depth - Minimum

18 5/8” (47.3 cm)

Maximum

20 1/8” (51.1cm)

Overall Width

30 3/4” (78.1 cm)

36 3/4” (93.3 cm)

Overall Height from Bottom 

5” (12.7 cm)

Overall Depth from Rear

21” (53.3 cm)

Gas Requirements

To field convert from natural or LP/Propane, the orifice spuds and regulator must be physically
changed.  Order conversion kit NK2VGSU to convert to natural and LPK3VGSU to convert to LP.

Uses standard residential 1/2” (1.3 cm) I.D. gas service line.

Electrical Requirements

120 VAC/60 Hz; 4 ft. (121.9 cm), 3-wire cord with grounded 3-prong plug attached to product.

Maximum Amp Usage

2.0 amps

Surface Burner Rating

Left Front-

16,000 Nat./15,500 LP (BTU)

16,000 Nat./15,500 LP (BTU)

(4.8 Nat./4.65 LP [kw])

(4.8 Nat./4.65 LP [kw])

Left Rear-   

12,000 Nat./11,500 LP (BTU)

12,000 Nat./11,500 LP (BTU) 

(3.6 Nat./3.45 LP [kw])

(3.6 Nat./3.45 LP [kw])

Center Front/Rear

N/A

12,000 Nat./11,500 LP (BTU)

(3.6 Nat./3.45 LP [kw])

Right Rear-   

8,000 Nat./7,500 LP (BTU)

8,000 Nat./7,500 LP (BTU)

(2.4 Nat./2.25 LP [kw])

(2.4 Nat./2.25 LP [kw])

Right Front-  

6,000 Nat./5,500 LP (BTU)

6,000 Nat./5,500 LP (BTU)

(1.8 Nat./1.65 LP [kw]) 

(1.8 Nat./1.65 LP [kw])

Approximate Shipping Weight

67 lb. (30.2 kg.)

80 lb. (36.0 kg)

BASIC SPECIFICATIONS

Содержание DGCU105

Страница 1: ...t Front 6 000 Nat LP BTU 6 000 Nat LP BTU 8 000 Nat LP BTU 1 8 Nat LP kw 1 8 Nat LP kw 2 1 Nat LP kw Approximate Shipping Weight 67 lb 30 2 kg 80 lb 36 0 kg 93 lb 41 9 kg DESCRIPTION VGSU102 30 W VGSU162 36 W Cutout Width Minimum 26 7 8 68 3 cm 34 3 8 87 3 cm Maximum 29 7 8 75 9 cm 35 7 8 91 1 cm Cutout Height Minimum 2 1 2 6 4 cm Cutout Depth Minimum 18 5 8 47 3 cm Maximum 20 1 8 51 1cm Overall W...

Страница 2: ...r non vented recirculating hood Nothing should obstruct the flow of combustion and ventilation air 10 Gas Manifold Pressure Natural gas 5 0 W C P LP Propane 10 0 W C P 11 Flexible Connections If the unit is to be installed with flexible couplings and or quick disconnect fittings the installer must use a flexible connector of at least 1 2 I D 1 3 cm NPT with suitable strain reliefs and comply with ...

Страница 3: ...inet above the cooktop must be a minimum of 36 91 4 cm above the countertop for a full width of the cooktop This minimum height requirement does not apply if a rangehood is installed over the cooking surface 5 A 120 volt wall receptacle should be located approximately 6 15 2 cm below the countertop cutout and 12 30 5 cm from the right side of the cutout MINIMUM CLEARANCES FROM ADJACENT COMBUSTIBLE...

Страница 4: ...ve the floor Refer to the rangehood installation instructions for further information These dimensions provide for safe and efficient operation of the hood 30 76 2 cm min 36 91 4 cm max 30 76 2 cm min 36 91 4 cm max 66 72 167 6 cm 182 9 cm 66 72 167 6 cm 182 9 cm 36 92 4 cm ISLAND INSTALLATION WALL INSTALLATION 36 92 4 cm Metal Hood Metal Hood Wood Composite Overlay Wood Composite Overlay Countert...

Страница 5: ...eight Dimension NOTE Minimum cutout height when using a 90o elbow supplied by installer 5 5 8 14 3 cm DGCU CUTOUT DIMENSIONS Cutout Opening 19 3 4 50 2 cm B B M Mi in n M Ma ax x 3 30 0 W W 2 28 8 3 3 4 4 7 73 3 0 0 c cm m 2 29 9 7 7 8 8 7 75 5 9 9 c cm m 3 36 6 W W 3 34 4 1 1 2 2 8 87 7 6 6 c cm m 3 35 5 7 7 8 8 9 91 1 1 1 c cm m 4 45 5 W W 4 42 2 7 7 8 8 1 10 08 8 9 9 c cm m 4 44 4 1 1 8 8 1 11 ...

Страница 6: ...ONS DGSU BURNER BOX DIMENSIONS Electric Cord 48 121 9 cm Gas Inlet 1 1 16 2 7 cm 1 1 16 2 7 cm 3 1 16 7 8 cm 30 W Model 29 1 8 74 0 cm 36 W Model 34 7 8 88 6 cm 19 3 4 50 2 cm C C C C M Mi in n M Ma ax x 3 30 0 W W 29 1 8 74 0 cm 29 7 8 75 9 cm 3 36 6 W W 34 7 8 88 6 cm 35 7 8 91 1 cm ...

Отзывы: