background image

USE/INSTALLATION

INSTRUCTIONS

24” W. UNDERCOUNTER/FREESTANDING
REFRIGERATED BEVERAGE CENTER
Retain for Future Reference

IMPORTANT - PLEASE READ AND FOLLOW

•    Before beginning, please read these instructions completely and carefully.
•  Do not remove permanently affixed labels, warnings, or plates from the product.  This may void the warranty.
•  Please observe all local and national codes and ordinances.
•  Please ensure that this product is properly grounded.
•                     The installer should leave these instructions with the consumer who should retain for local inspector’s use and for

future reference.

WARNING

::

T

To

o  rre

ed

du

ucce

e  tth

he

e  rriisskk  o

off  ffiirre

e,,  e

elle

eccttrriicca

all  ssh

ho

occkk,,  o

orr  iin

njju

urryy  w

wh

he

en

n  u

ussiin

ng

g  yyo

ou

urr  rre

effrriig

ge

erra

atte

ed

d  b

be

evve

erra

ag

ge

e  cce

en

ntte

err,,  ffo

ollllo

ow

w  b

ba

assiicc

p

prre

ecca

au

uttiio

on

nss  iin

nccllu

ud

diin

ng

g  tth

he

e  ffo

ollllo

ow

wiin

ng

g::

•FOR YOUR SAFETY•

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR
ANY OTHER APPLIANCE.  THE FUMES CAN CREATE A FIRE HAZARD OR EXPLOSION.

IItt  iiss  yyo

ou

urr  rre

essp

po

on

nssiib

biilliittyy  tto

o  b

be

e  ssu

urre

e  yyo

ou

urr  rre

effrriig

ge

erra

atte

ed

d  b

be

evve

erra

ag

ge

e  cce

en

ntte

err  iiss::

•located so the front is not blocked to restrict incoming or discharge air flow.
•properly leveled.
•located in a well ventilated area. 
•connected to the proper kind of outlet, with the correct electric supply and grounding.  A 115 volt, 60 Hz, 15 amp

fused electrical supply is required.  N

NO

OT

TE

E:: Time delay fuse or circuit breaker is recommended.

•not used by anyone unable to operate it properly.
•used only for its intended purpose.
•properly maintained.

•SAVE THESE INSTRUCTIONS•

41009338

Rev B

DANGER

SUFFOCATION HAZARD

Remove doors from your old refrigerated beverage center.
Failure to do so can result in child entrapment, which can cause death
or brain damage.

IMPORTANT:

Child entrapment and suffocation are not problems of the

past.  Junked or abandoned refrigerated beverage centers are still
dangerous, even if they will sit for “just a few days.”  If you are getting rid
of your refrigerated beverage center, please follow the instructions below
to help prevent accidents.

BEFORE YOU THROW AWAY YOUR OLD REFRIGERATION PRODUCT: 

•Take off the doors.
•Leave the shelves in place so that children may not easily climb inside.

PROPER DISPOSAL OF YOUR OLD REFRIGERATION PRODUCT

Содержание Designer DUAR140R

Страница 1: ...OSION I It t i is s y yo ou ur r r re es sp po on ns si ib bi il li it ty y t to o b be e s su ur re e y yo ou ur r r re ef fr ri ig ge er ra at te ed d b be ev ve er ra ag ge e c ce en nt te er r i is s located so the front is not blocked to restrict incoming or discharge air flow properly leveled located in a well ventilated area connected to the proper kind of outlet with the correct electric s...

Страница 2: ...th clearance if door is recessed between cabinets SPECIFICATIONS DIMENSIONS PROFESSIONAL SERIES B Ba as si ic c E El le ec ct tr ri ic c D Da at ta a 115 VAC 60 Hz Maximum amps 3 3 Approximate Shipping Weight 140 lbs 63 2 kg Min 34 1 4 87 0 cm Max 35 88 9 cm with leveling legs fully extended 30 3 4 78 1 cm 23 7 8 60 6 cm 47 1 4 120 0 cm 22 55 9 cm 24 3 8 61 9 cm 26 7 8 68 3 cm ...

Страница 3: ... 3 Approximate shipping weight 140 lbs 63 2 kg Front View 30 3 4 78 1 cm Mín 34 1 4 87 0 cm Max 35 88 9 cm with leveling legs fully extended 23 7 8 60 6 cm Side View DUAR 22 55 9 cm 24 3 8 61 9 cm 25 3 8 64 5 cm 47 1 4 120 0 cm Side View DFUR 22 55 9 cm 24 3 16 61 4 cm 47 1 4 120 0 cm to front of locally supplied custom panel ...

Страница 4: ... in a well ventilated area with temperature above 400 F 4 40 C and below 1100 F 430 C Best results are obtained at temperatures between 600 F 160 C and 1000 F 380 C 3 Provisions for electricity should be determined before placing unit in proper place REVERSIBLE DOOR Professional Series Glass Door Units Only You can change the door swing from right to left hinge very easily 1 Simply unscrew the top...

Страница 5: ... the 10 32 machine screws and a 1 8 allen head driver as shown in Figure 1 below 2 Press in the shoulder bushings to the top and bottom door hinge brackets Make certain that the shoulder is to the outside of the door as shown in Figure 1 below 3 Test fit the door to the unit to make certain door will hang correctly The door is hung correctly when the top of the door is parallel to the top of the u...

Страница 6: ...he Wood Frame DFUR MODEL F FO OR R A A 3 3 1 1 2 2 T TO OE E K KI IC CK K C CO OV VE ER RS S T TH HE E E EN NT TI IR RE E D DO OO OR R E EX XT TR RU US SI IO ON N M Mi in n 5 5 8 8 1 1 7 7 c cm m M Ma ax x 3 3 4 4 1 1 9 9 c cm m ...

Страница 7: ...ed Make certain the light is able to turn on and off when the door is opened and closed 9 Attach the door to the unit by reversing step number 1 above Magnetic door gasket Rear of Door Bottom of door Attached wood frame 3 8 clearance holes for frame wood screws 10 holes 1 8 allen head screws for hinge adjustment Door hinge adjustment screws Door light striker plate Attaching the Handle Attach the ...

Страница 8: ...ocal codes and ordinances The third ground plug SHOULD NOT under any circumstances be cut or removed All UL listed refrigerated beverage centers are equipped with this type of plug Power Supply with 3 prong grounding plug Grounding type wall receptacle WARNING ELECTRICAL SHOCK HAZARD Failure to follow these instructions could result in fire or electrical shock LEG LEVELER INSTALLATION R Re ea ad d...

Страница 9: ...ers If it is necessary to scrape stainless steel to remove encrusted materials soak with hot wet cloths to loosen the material then use a wood or nylon scraper Do not use a metal knife spatula or any other metal tool to scrape stainless steel scratches are almost impossible to remove WIRING DIAGRAM UNDERCOUNTER 24 W REFRIGERATED BEVERAGE CENTER W WA AR RN NI IN NG G E EL LE EC CT TR RI IC CA AL L ...

Страница 10: ...ult in electrical shock Light Shield Screws OPERATING INSTRUCTIONS S Se et tt ti in ng g t th he e C Co on nt tr ro ol ls s The total available temperature range of the indoor unit is from 39 420 F 4 0 5 60 C to 54 560 F 12 130 C The total available temperature range of the outdoor unit is from 33 350 F 0 5 1 10 C to 54 560 F 12 130 C The higher the number selected the cooler temperature within th...

Страница 11: ...and lasts longer when maintained properly and kept clean C Co on nd de en ns se er r The condenser tubing inside the cabinet does not require frequent cleaning however satisfactory cooling depends on adequate ventilation over the coils Be sure that nothing obstructs the required air flow openings in front of the cabinet Spiders and insects can nest in and around the refrigerated beverage center ca...

Страница 12: ...EF FE ER RR RE ED D S SE ER RV VI IC CE E 1 11 11 1 F Fr ro on nt t S St tr re ee et t G Gr re ee en nw wo oo od d M Mi is ss si is ss si ip pp pi i 3 38 89 93 30 0 U US SA A Record the following information indicated below You will need it if service is ever required The serial number and model number for your refrigerated beverage center is located on the front of the unit at the base of the doo...

Страница 13: ... improper installation improper operation or repair or service to the product by anyone other than an authorized Viking Range Corporation service agency or representative Warranty shall not apply to damage resulting from indoor units being used in outdoor situations This warranty does not apply to commercial usage Warrantor is not responsible for consequential or incidental damage whether arising ...

Страница 14: ... any reason alteration improper installation improper operation or repair or service to the product by anyone other than an authorized Viking Range Corporation service agency or representative Warranty shall not apply to damage resulting from indoor units being used in outdoor situations This warranty does not apply to commercial usage Warrantor is not responsible for consequential or incidental d...

Отзывы: