Viking DCWH series Скачать руководство пользователя страница 22

43

42

Measure down 1-13/16 (4.6 cm) from desired height of

hood and secure 1-1/2” x  3/4” wood strip (not

included) to wall using screws provided. 

Use additional mounting screws to secure hood to

wood strip. 

Installation

(DCWH Classic Chimney Wall Hoods)

CAUTION: 

Secure vent hood to wall using screws provided.

Make sure mounting screws are secured into frame. Use
additional mounting screws and wall anchors, if necessary. 

CAUTION:

If not using a duct cover, using screws provided

make sure top mounting screws are secured into soffit or
cabinet frame. Use additional mounting screws, if necessary. 

Slide filter front over front lip. Push filter rear up, then

slide back over rear lip.

Slide spacer front over front lip. Push spacer rear up,

then slide back over rear lip.

Slide filter front over front lip. Push filter rear up, then

slide back over rear lip.

Measure distance from ceiling to canopy.

Tape to avoid scratching.

Duct Cover Option

(DCWH Classic Chimney Wall Hoods)

Содержание DCWH series

Страница 1: ...allation Guide Professional Outdoor Hoods Viking Range Corporation 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking...

Страница 2: ...ore servicing or cleaning unit switch power off at service panel and lock service panel to prevent power from being switched on accidentally When the service disconnecting means cannot be locked secur...

Страница 3: ...HE FIRE DEPARTMENT 2 NEVER PICK UP A FLAMING PAN You may be burned 3 DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result 4 Use an extinguisher ONLY if You know it...

Страница 4: ...6 Clearance Dimensions 7 Interior Ventilator Dimensions 460 CFM Interior Ventilator Installation Top View VWH 10 H Wall Hoods w Standard Ventilator VWH 10 H Wall Hoods w Standard Ventilator...

Страница 5: ...s Description 30 36 42 48 54 60 Duct cover width 29 7 8 75 9 cm 35 7 8 91 1 cm 41 7 8 106 4 cm 47 7 8 121 6 cm 53 7 8 136 8 cm 59 7 8 152 1 cm Duct cover depth 12 30 5 cm Duct cover height 12 30 5 cm...

Страница 6: ...Installation for all Wall Hoods 1200 or 1500 CFM Exterior or In Line Ventilator Installation for all Wall Hoods 300 or 600 CFM Interior Ventilator Installation for all Wall Hoods 1200 CFM Interior Ven...

Страница 7: ...e 30 76 2 cm to 36 91 4 cm above the grill surface The hood should be installed 4 1 2 11 4 cm plus the distance between the back trim and surface from the back wall Note There is a 3 minimum clearance...

Страница 8: ...4 60 66 Duct cover width 12 30 5 cm 12 30 5 cm 12 30 5 cm 18 45 7 cm 18 45 7 cm 24 61 0 cm 24 61 0 cm Duct cover depth 12 30 5 cm Duct cover height 12 30 5 cm to 24 61 0 cm Number of lights 2 2 2 3 3...

Страница 9: ...n for 30 36 42 models 900 1200 or 1500 CFM Exterior or In Line Ventilator Installation for 48 54 60 66 models 300 or 600 CFM Interior Ventilator Installation for 30 36 42 models 1200 CFM Interior Vent...

Страница 10: ...4 cm 12 30 5 cm 12 30 5 cm 18 45 7 cm Duct cover depth 12 30 5 cm Duct cover height 18 45 7 cm to 30 76 2 cm 16 40 6 cm to 28 71 1 cm 16 40 6 cm to 28 71 1 cm 16 40 6 cm to 28 71 1 cm Number of lights...

Страница 11: ...r 30 36 42 Hoods 900 or 1200 CFM Exterior or In Line Ventilator Installation for 30 36 42 Hoods Top View Top View Top View Top View 900 1200 or 1500 CFM Exterior or In Line Ventilator Installation for...

Страница 12: ...al duct cover sold separately VCIH Chimney Island Hoods 36 42 54 66 VCIH Chimney Island Hoods Description 36 42 54 66 Duct cover width 12 30 5 cm 12 30 5 cm 18 45 7 cm 24 70 0 cm Duct cover depth 12 3...

Страница 13: ...ney Island Hoods 900 1200 or 1500 CFM Exterior or In Line Ventilator Installation for all Chimney Island Hoods 600 CFM Interior Ventilator Installation for all Chimney Island Hoods 1200 CFM Interior V...

Страница 14: ...the ventilator system may be mounted as shown on page 25 Installing Hood Canopy Custom Hood Canopy 1 Position ventilator system inside of the custom hood canopy and center it front to back and left t...

Страница 15: ...nterior Ventilator Installation 900 or 1200 CFM Exterior or In Line Ventilator Installation 30 36 42 W Models 300 or 600 CFM Interior Ventilator Installation 30 36 42 W Models C 30 W 28 1 4 71 8 cm 36...

Страница 16: ...each 90 elbow is equivalent to 5 10 feet 1 52 3 05 cm of straight run Never use flexible duct it creates back pressure air turbulence and greatly reduces performance Proper performance is dependent on...

Страница 17: ...re Text goe here Text goe here Text goe here Text goe here Check damper for unrestricted movement adjust if necessary Attach transition to damper Seal with aluminum tape Flip hood over and remove elec...

Страница 18: ...rer Before servicing or cleaning unit switch power off at service panel and lock service panel to prevent power from being switched on accidentally When the service disconnecting means cannot be locke...

Страница 19: ...net framing use additional mounting screws if necessary Slide filter front over front lip Push filter rear up then slide back over rear lip 36 Connect black to black white to white and the green bare...

Страница 20: ...vided Measure distance from ceiling to canopy Tape to avoid scratching Duct Cover Option VCWH Chimney Wall Hoods 38 Slide spacer front over front lip Push spacer rear up then slide back over rear lip...

Страница 21: ...Number of spacers and baffles may vary by model Slide filter front over front lip Push filter rear up then slide back over rear lip 40 Check framing where cutout will be NOTE 200 lb limit Cut appropr...

Страница 22: ...crews and wall anchors if necessary CAUTION If not using a duct cover using screws provided make sure top mounting screws are secured into soffit or cabinet frame Use additional mounting screws if nec...

Страница 23: ...d it if service is ever required The serial number and model number for your appliance are located on the identification plate mounted on the inside of the hood canopy Model number ___________________...

Страница 24: ...47 46...

Отзывы: