Viking CPA-7A Скачать руководство пользователя страница 2

Installation/Applications

ZF280065 Rev B

Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice.  Viking
Electronics, its affiliates and/or subsidiaries assume no responsibility for errors and/or omissions contained in this information.  Revisions of
this document or new editions of it may be issued to incorporate such changes.

Product Support Line...(715) 386-8666           Fax Back Line...(715) 386-4345

Fax Back Doc # 455

Printed in the U.S.A.

A.  Centrex or Ringing Analog PABX/KSU Station 

1.  Set the trunk station switch to the S position.

2.  Adjust the TIME OUT control as required
     (8 - 25 seconds).

3.  With the night transfer switch off (open), the 
     CPA-7A will answer and page, then disconnect 
     on CPC or time out.  

4.  With the night transfer switch on (closed), the 
     CPA-7A will broadcast an electronics warble 
     tone with each ring.

B.  Unused Phone System Trunk Input

1.  Set the trunk station switch to the T position.

2.  Adjust the TIME OUT control to the maximum.

3.  If both paging and loud common audible are 
     required, wire the night transfer switch, the 
     common audible dry contacts and jumper 
     terminal 3 to 4 as shown to the right.

Night Transfer Switch

(not included)

1    2    3    4    5    6    7

S

T

Background

music source

Up to (8)

8 Ohm

speakers

Common

Speaker

Night bell
Contact Closure
Talk Battery
Music Input

Centrex line, C.O.

line or analog

PABX/KSU station

Provides talk battery

Night Transfer Switch (not included)

Key system

common audible

dry contact

closure

1    2    3    4    5    6    7

S

T

Background

music source

Up to (8)

8 Ohm

speakers

Common

Speaker

Night bell
Contact Closure
Talk Battery
Music Input

Unused

PABX/KSU

Trunk Port

1N 4004 Diode (included)

D.  600 ohm Paging Port

 (with page dry contact closure provided)

1.  Set the trunk station switch to the T position.

2.  Adjust the TIME OUT control to the maximum.

3.  Do NOT strap terminal 2 to terminal 5.

4.  Connect the page dry contacts to terminals 2 
     and 4.  Closure will activate the alert tone for 
     paging and mute the background music. 

5.  If both paging and loud common audible are 
     required, wire the night transfer switch, the 
     common audible dry contacts and the included 
     1N 4004 diode as shown to the right.

Night Transfer Switch (not included)

Key system

dry contact

closures

Page

Common

Audible

Night bell
Contact Closure
Talk Battery
Music Input

 PABX/KSU

Page Port

1    2    3    4    5    6    7

S

T

Background

music source

Up to (8)

8 Ohm

speakers

Common

Speaker

C.  600 ohm Paging Port

1.  If the phone system does NOT provide a dry contact 
     closure on “Page”, connect the paging port to the 
     music input, terminals 6 and 7.  

     

Note:  The CPA-7A can NOT provide background 

     music or alert tones in this application.

2.  If loud common audible is required, wire the night 
     transfer switch, the common audible dry contacts and 
     jumper terminal 3 to 4 as shown to the right.

Night Transfer Switch (not included)

Key system

common audible

dry contact

closure

1    2    3    4    5    6    7

S

T

Up to (8)

8 Ohm

speakers

Common

Speaker

Night bell
Contact Closure
Talk Battery
Music Input

PABX/KSU

Page Port

Отзывы: