Water Filter System Specifi cation and Performance 
Data Sheet 

 

Contaminant

Reduction

  Average 

Infl uent

 

   NSF  Specifi ed Chal-

lenge 

Concentration

   Avg  % 

Reduction

 Average

Product Water 
Concentration

 Max  Permissible 

Product Water 
Concentration

   NSF

Reduction

Requirements

 NSF  Test

Report

 Chlorine  Taste  and 
Odor

 2.0  mg/L

 2.0 mg/L + 10%

 97.5%

 0.05 mg/L

 N/A

 >  50%

 J-00056501

 Nominal  Particulate
Class I, >0.5 to <  
1.0 μm

 13,666,667 

pts/mL

At least 10,000 

particles/mL

98.9%

143,333 

pts/mL

N/A

> 85%

J-00056506

 Asbestos

 96  MF/L

10

7

 to 10

8

 fi bers/L; 

fi bers greater than 

10μm in length

>99%

<1 MF/L

N/A

> 99%

J-00056511

 Atrazine

 0.010  mg/L

0.009 mg/L + 10%

89.3%

0.001 mg/L

0.003 mg/L

N/A

J-00056512

 Cyst*

 122,500 

cysts/L

Minimum 50,000 

cysts/L

99.99%

1 cyst/L

N/A

> 99.95%

J-00056513

 Lead @ pH 6.5

 0.153 mg/L

0.15 mg/L + 10%

99.3%

0.001 mg/L

0.010 mg/L

N/A

J-00056515

 Lead @ pH 8.5

 0.150 mg/L

0.15 mg/L + 10%

99.3%

0.001 mg/L

0.010 mg/L

N/A

J-00058784

 Lindane

 0.002  mg/L

0.002 mg/L + 10%

97.8%

0.00004 mg/L

0.0002 mg/L

N/A

J-00058969

 Mercury @ pH 6.5

 0.006 mg/L

0.006 mg/L + 10%

95.0%

0.0003 mg/L

0.002 mg/L

N/A

J-00058785

 Mercury @ pH 8.5

 0.006 mg/L

0.006 mg/L + 10%

88%

0.0007 mg/L

0.002 mg/L

N/A

J-00058783

 Toxaphene

 0.015  mg/L

0.015 mg/L + 10%

93.2%

0.001 mg/L

0.003 mg/L

N/A

J-00056531

 Turbidity

 10.8  NTU

11 + 1 NTU

98.7%

0.153 NTU

0.5 NTU

N/A

J-00058972

 *Based on the use of Cryptosporidium parvum oocysts

Operating Specifi cations

 

Capacity:   

 

 

Certifi ed for up to 750 gallons (2,838 L); up to nine months

 

Pressure Requirement:   20 - 120 psi (1.4 - 8.2 bar)

 

Temperature:   

33-100º F (0.6 - 37.8º C)

 

Flow rate: 

 

 

0.78 gpm (2.9 l/min.)

Check for compliance with the state and local laws and regulations.

Note:

 While the testing was performed under standard laboratory conditions, actual performance 

may vary.  

Must be installed and operated in accordance with manufacturer’s recommended procedures and 

guidelines. Installation instructions, parts and service availability, and standard warranty are included with 

the product when shipped. This drinking water system must be maintained according to manufacturer’s 

instruction, including replacement of fi lter cartridges.

 Manufactured  by: 

3M Purifi cation Inc.

400 Research Parkway

Meriden, CT  06770

 

System tested and certifi ed by NSF International against 
Standard 42 for the reduction of chlorine taste and odor, 
particulate Class I and Standard 53 for the reduction 
of Lead, Lindane, Atrazine, Mercury, Toxaphene, Cyst, 
Turbidity, and Asbestos.

 This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed 

below. The concentration of the indicated substances in water entering the system was reduced to a 

concentration of less than or equal to the permissible limit for water leaving the system, as specifi ed in 

NSF/ANSI 42/53.* (100% safety factors built-in for unmetered usage for health claims only.)

Содержание CFBI7360

Страница 1: ...Installation Guide Integrated Refrigerator Freezer 7 SERIES VBI7360 CVBI7360 FBI7360 CFBI7360 MVBI7360 CMVBI7360 MFBI7360 CMFBI7360 ...

Страница 2: ...________________________________________ 11 Custom Front Panel Dimensions ______________________________________________________ 12 Custom Front Panel Install ___________________________________________________________ 13 Water Line Installation ______________________________________________________________ 14 Leveling Unit______________________________________________________________________ 16 K...

Страница 3: ...t can happen if the instructions are not followed Your safety and the safety of others is very important We have provided many important safety messages in this manual and on your appliance ALWAYS read and obey all safety messages This is the safety alert symbol This symbol alerts you to hazards that can kill or hurt you and others All safety messages will be preceded by the safety alert symbol an...

Страница 4: ...ired it should be Of the receptacle type breaker type or portable type NOT recommended Used with permanent wiring only temporary or portable wiring NOT recommended On a dedicated circuit no other receptacles switches or loads in the circuit Connected to a standard breaker of appropriate size GFI breaker of the same size NOT recommended Rated for Class A 5 mA 1 mA trip current as per UL 943 standar...

Страница 5: ...3 2 cm 36 91 4 cm 22 1 2 57 2 cm 4 1 16 10 3 cm A Dimensions Integrated Bottom Freezer Model Dimension A Dimension B VBI7360 CVBI7360 27 3 8 69 5 cm 24 3 4 62 9 cm FBI7360 CFBI7360 N A 24 61 0 cm MVBI7360 CMVBI7360 27 68 5 cm 24 3 4 62 9 cm To outside of door panel ...

Страница 6: ... dimensions Refrigerator Freezer Total capacity 13 6 cu ft 385 8 liters 6 35 cu ft 180 1 liters 19 95 cu ft 565 9 liters Approximate shipping weight 565 lbs 254 3 kg 36 Integrated Refrigerator Freezer w Custom Panels Description FBI7360 CFBI7360 Overall width 36 91 4 cm Overall height from bottom 83 15 16 213 2 cm min to 84 3 4 215 7 cm max Overall depth from rear To front edge kickplate 22 1 2 57...

Страница 7: ...6 3cm max opening height 36 91 5 cm 25 63 5 cm Electric Outlet Location Water Line Entry Area 3 7 6 cm 6 15 2 cm 5 8 1 6 cm 36 91 5 cm 1 2 1 3 cm 15 1 2 39 4 cm 4 1 4 10 8 cm leveling dimension Note For all models 3 back from the front of the cabinet on both sides needs to finished like the outside of the cabinets ...

Страница 8: ...e it must be installed according to the instructions including the anti tip bracket C C Cabinet Rear Floor A Cabinet Opening Dimension A Cabinet opening minus the refrigerator height 1 1 4 3 2 cm Anti tip Bracket There are 12 hole locations on the anti tip bracket Of those 12 at least 4 places must be used NOTE Number of fasteners must be suitable for load in order to prevent tipping ...

Страница 9: ...ngrounded two prong adapter If codes permit a separate grounding wire to be used it is recommended that a qualified electrician determine that the grounding path is adequate DO NOT ground to a gas line Check with a qualified electrician if you are not sure if the appliance is properly grounded DO NOT have a fuse in the neutral or grounding circuit Anti Tip Requirements The anti tip device should b...

Страница 10: ... vertical or horizontal 1 2 1 3 cm to 1 1 4 3 2 cm COLD water line near water area Run water line through the floor back or side wall in area shown on page 7 Connect to water supply coming from back of unit on the left side Water pressure must be greater than 20 psi and less than 120 psi on non dispenser units and greater than 35 psi and less than 120 psi on dispenser units Area Requirements Most ...

Страница 11: ...se excess packaging to protect decorative trim also verify that leveling legs are up 0 adjustment Door Drawer Panel Adjustments On the side of each panel at the top and bottom there is a vertical slot with a cam spacer for front to back adjustments In the center there is a horizontal adjustment for up and down All hardware needs to be loosened before adjusting F Vertical slot for front to back adj...

Страница 12: ...um panel weight Refrigerator door panel 39 lbs 17 6 kg Top Freezer drawer panel 10 lbs 4 5 kg Bottom Freezer drawer panel 13 lbs 5 9 kg 35 1 16 89 1 11 32 87 cm 6 31 32 17 7 cm 6 15 16 17 6 cm 16 15 16 43 0 cm 18 15 16 48 1 cm 28 15 16 73 5 cm 11 32 87 cm 1 5 32 2 9 cm 2 9 16 6 5 cm 7 1 16 17 9 cm 35 1 16 89 1 35 1 16 89 1 11 32 87 cm 2 7 32 5 6 cm 2 1 4 5 7 cm 5 15 32 13 9 cm 8 23 32 22 1cm 12 7 ...

Страница 13: ...13 Optional Custom Front Panels Install In order to access the mounting holes unsnap panel trim on both sides of all three doors Panel trim Mounting screw location 2 per panel F ...

Страница 14: ...ottom freezer drawer Remove the toe kick by removing the screws on each side Remove the grill by unsnapping the panel from the frame WARNING TIP OVER HAZARD Appliance is top heavy and tips easily when not completely installed To avoid a hazard due to instability of the appliance it must be installed according to the instructions including the anti tip bracket ...

Страница 15: ... cabinet cut out Coil the copper tubing in a vertical loop so that the end of the copper tube faces toward the rear of the refrigerator Install nut and ferrule over end of copper tube Insert the end of the copper tube into the water valve Tighten the nut until the ferrule fits snug on the copper tube Turn on water supply and check for leaks Repair leaks if found Level the refrigerator replace the ...

Страница 16: ...adjustments are less likely to be necessary IMPORTANT NOTE Level the unit to the floor not surrounding cabinetry This could affect the operation of the unit such as door closing A B Front Panel Left Front Adjustment Right Front Adjustment Left Rear Adjustment Right Rear Adjustment Kickplate Installation After the unit has been adjusted to the proper height place the kickplate on the lower front wi...

Страница 17: ...sten the unit to the cabinetry on both sides NOTE Only use the screws provided and use caution when installing the fastening screws to prevent scratching the frame Use a 3 Phillips driver to prevent damage Snap the flush mount side trim to the side opposite the door swing Replace the drawers and close the door Attach unit to cabinetry on both sides Side trim is taped to the side unit Remove and sn...

Страница 18: ...op of the door hinge Remove the two screws and door stop Rotate the door stop 180o degrees so that the shorter end faces away from the door Replace door stop and screws For additional information on the door stop adjustment visit the product information tab for 7 Series Bottom Mount Refrigerators online at vikingrange com in the US or brigade ca in Canada Door Stop Remove screws and door stop Rota...

Страница 19: ...0058972 Based on the use of Cryptosporidium parvum oocysts Operating Specifications Capacity Certified for up to 750 gallons 2 838 L up to nine months Pressure Requirement 20 120 psi 1 4 8 2 bar Temperature 33 100º F 0 6 37 8º C Flow rate 0 78 gpm 2 9 l min Check for compliance with the state and local laws and regulations Note While the testing was performed under standard laboratory conditions a...

Страница 20: ...display will flash PL Press the refrigerator select button twice to initiate display 2 Verify unit is not in Sabbath Mode If in Sabbath Mode A The Sabbath Mode will disable the interior lights display except SAB indicator temperature and compartment indicator and alarm If in Sabbath Mode SAB will be lit To exit the Sabbath Mode B Press and hold SAB button for 3 seconds 3 Verify unit is not in Show...

Страница 21: ...or your appliance are located on the identification plate mounted behind the top light Record the information indicated below You will need it if service is ever required Model number ________________________________________________________________________ Serial number _________________________________________________________________________ Date of purchase ______________________________________...

Страница 22: ...22 ...

Страница 23: ...23 ...

Страница 24: ...N Viking Range LLC 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 845 4641 or visit our web site at vikingrange com in the US or brigade ca in Canada 072517 UL C UL ...

Отзывы: