B.  Add Paging, Music-On-Hold, and Loud Ringing with a Viking SLP-1

For more information and installation instructions on the 

SLP-1

, see 

DOD# 478

.

VIKING

©

MODEL SLP-1

DOOR BELL

SW. INPUT

LOUD RING

ENABLE

-        +

I.O.  COM.

ON

 1     2     3

SINGLE LINE

PAGING CONTROLLER

PWR 13.8 V

AC

VIKING

ELECTRONICS

HUDSON, WI 54016

AUDIO

INPUT

L             R

AUDIO

OUTPUT

L             R

MUSIC

ON

HOLD

INPUT

2 WATT

AMP GAIN

MIN

MAX

PREAMP
VOLUME

MIN

MAX

PWR

PAGE

MUTE

PAGE TRIG. OUT

C.O. LINE

INPUT

OUT TO

PHONES

-  SPKR  +

OUTPUT

L

L

R

R

-                  +

C.O. / Phone

Line Input

Analog

Phone

* Earth Ground

(optional)

E-40-SS

(

not included)

Optional wiring for door chime
over speakers. If used, set the 

C-200

 DIP switch 2 to OFF.

Entry Door

Phone

To Additional

Analog Phones

EARTH

GND

C.O. LINE

INPUT

OUT TO

PHONES

ENTRY

PHONE

N.O.   COM   N.C.
AUX CONTACTS

ON

 1     2     3

AUX POWER

OUTPUT

VIKING

POWER 13.8V AC

©

VIKING

ELECTRONICS

HUDSON, WI 54016

SINGLE ENTRY PHONE

CONTROLLER

MODEL C-200

RING COUNT

1

EARTH GND

1

RELA

Y

 MODE

2

DOORBELL

 MODE

3

IN USE

LINE IN

2

3

PHONES

4

5

ENTR

Y

6

7

8

9

AUX POWER

OUTPUT

10 11 12

AUXILIAR

Y

RELA

Y

  

N.O. 

COM 

N.C.

For more information and installation instructions on the 

RC-2A

, see 

DOD# 160

.

C.  Add Door Strike Relay Control with a Viking RC-2A

* Note:

To increase surge protection, fasten a wire from the screw

terminal to Earth Ground (grounding rod, water pipe, etc.)

C.O. / Phone

Line Input

Analog

Phone

* Earth Ground

(optional)

To Additional
Analog Phones

REMOTE TOUCH TONE

RELAY CONTROLLER

VIKING

©

MODEL RC-2A

POWER 12V DC

RELAY

CONTACTS

PROGRAMMING

SWITCHES

ENTRY CODE

N.O.

N.C.

COM

1

2

3

1

2

3

4

5

6

7

8

EARTH

GND 

PWR IN/OUT

12-24V AC/DC

LINE IN

VIKING

ELECTRONICS

HUDSON, WI 54016

C

C

1

2

3

4

5

6

7

ON

S1

S2

S3

0 1 2 3

 4

 5

 6

 7 8

 9 

A B

 C

 D

 E

 F

0 1 2 3

 4

 5

 6

 7 8

 9 

A B

 C

 D

 E

 F

0 1 2 3

 4

 5

 6

 7 8

 9 

A B

 C

 D

 E

 F

Note: Gate controllers do not

typically require power.

EARTH

GND

C.O. LINE

INPUT

OUT TO

PHONES

ENTRY

PHONE

N.O.   COM   N.C.
AUX CONTACTS

ON

 1     2     3

AUX POWER

OUTPUT

VIKING

POWER 13.8V AC

©

VIKING

ELECTRONICS

HUDSON, WI 54016

SINGLE ENTRY PHONE

CONTROLLER

MODEL C-200

RING COUNT

1

EARTH GND

1

RELA

Y

 MODE

2

DOORBELL

 MODE

3

IN USE

LINE IN

2

3

PHONES

4

5

ENTR

Y

6

7

8

9

AUX POWER

OUTPUT

10 11 12

AUXILIAR

Y

RELA

Y

  

N.O. 

COM 

N.C.

E-40-SS

(

not included)

Entry Door

Phone

5A @ 30V DC

250V AC

maximum

(not included)

Doorstrike / 

Magnetic Lock

Door

* Note:

To increase surge protection, fasten a wire from the

screw terminal to Earth Ground (grounding rod, water pipe, etc.)

Содержание C-200

Страница 1: ...imum Talk Battery 32V DC Connections 12 cage clamp screw terminals C 200 Basic Single Entry Phone Interface August 18 2015 Applications Specifications www vikingelectronics com Information 715 386 8861 VIKING Allows single line telephones or a telephone system to share a phone line with a door entry phone House phones ring with C O line cadence or distinctive ring when the entry phone Call button ...

Страница 2: ...y Contacts C O Line Entry Door Phone Phones or Phone System Simplified Schematic In Use LED Not a Power Indicator GND 12VDC Auxiliary Power Output Line Circuit EARTH GND C O LINE INPUT OUT TO PHONES ENTRY PHONE N O COM N C AUX CONTACTS ON 1 2 3 AUX POWER OUTPUT VIKING POWER 13 8V AC VIKING ELECTRONICS HUDSON WI 54016 SINGLE ENTRY PHONE CONTROLLER MODEL C 200 RING COUNT 1 EARTH GND 1 RELAY MODE 2 D...

Страница 3: ... instructions on the RC 2A see DOD 160 C Add Door Strike Relay Control with a Viking RC 2A Note To increase surge protection fasten a wire from the screw terminal to Earth Ground grounding rod water pipe etc C O Phone Line Input Analog Phone Earth Ground optional To Additional Analog Phones REMOTE TOUCH TONE RELAY CONTROLLER VIKING MODEL RC 2A POWER 12V DC RELAY CONTACTS PROGRAMMING SWITCHES ENTRY...

Страница 4: ...1 RELAY MODE 2 DOORBELL MODE 3 IN USE LINE IN 2 3 PHONES 4 5 ENTRY 6 7 8 9 AUX POWER OUTPUT 10 11 12 AUXILIARY RELAY N O COM N C E 40 SS not included Entry Door Phone EARTH GND C O LINE INPUT OUT TO PHONES ENTRY PHONE N O COM N C AUX CONTACTS ON 1 2 3 AUX POWER OUTPUT VIKING POWER 13 8V AC VIKING ELECTRONICS HUDSON WI 54016 SINGLE ENTRY PHONE CONTROLLER MODEL C 200 RING COUNT 1 EARTH GND 1 RELAY M...

Страница 5: ... Phone call button The doorbell activation can be used in addition to the double ring cadence to further identify the call is from the Entry Phone Alternatively phone ringing can be disabled see Ringing section below in which the doorbell will be the only indication that a visitor is waiting at the Entry Phone With the Aux Relay programmed to operate a camera or courtesy lights DIP switch 2 set to...

Страница 6: ...oor or gate The E 50 s compact size allows it to be mounted in a standard single gang electrical box The E 50 is available in five different attractive finishes to match your door hardware light fixtures etc Replacement E 50 faceplates PNL50 can be purchased separately and are available in all five standard finishes The E 50 entry phones can share a single phone line with house or small business t...

Страница 7: ...10A and E 20B are available with Enhanced Weather Protection EWP For more information on the E 10A or E 20B see DOD 210 Model E 30 Model E 35 with built in camera The E 30 handsfree phone is designed to provide quick and reliable handsfree communication and can be connected directly to a C O line or analog PABX KSU station The E 30 features non volatile memory a built in dialer and intelligent cal...

Страница 8: ...ATED TO THE SALE OR USE OF THE PRODUCT SOLD HEREUNDER EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY WHETHER IN AN ACTION BASED ON CONTRACT TORT INCLUDING NEGLIGENCE OR STRICT LIABILITY OR ANY OTHER LEGAL THEORY ANY LIABILITY OF VIKING SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF THE PRODUCT OR AT VIKING S OPTION REFUND OF THE PURCHASE PRICE AS THE EXCLUSIVE REMEDY AND ANY LIABILITY OF VIKING SHALL ...

Отзывы: