The tenant names and phone numbers must be programmed into the system
for proper operation.  This programming is done through the telephone line
interface using the 

PB-100

special software.  This allows either remote pro-

gramming from a distant location, or local programming using the Viking

DLE-300

line simulator.  The 

PB-100

is connected to a serial port of a P.C.

and Windows based software is used to enter tenant names, phone numbers
and the recording for the voice directory.  A data base is constructed for each
apartment to make future changes easier.  When the Remote Programmer
software is first invoked, the screen at the right pops up (right).  After a few
seconds, the "Building Selection" screen will appear.

The following sections provide a brief overview of programming screen shots
and descriptions.  Complete programming instructions are available only in
the software itself.

C. Wiring Connections

Once the 

AES-2000

is secured to the wall,  the unit can be connected to the building wiring.  

1.

Remove the 2.1 mm plug from the end of the AC power adapter cord.  The AC adapter can be located up to 100 

feet away from the entry system when using a minimum of 24 AWG  wire.  

2.

Make all connections to the 

AES-2000

panel before inserting the adapter into a wall outlet.  The two wires from the 

AC adapter connect to the two terminal block positions labeled "13.8 VAC". 

3.

If the incoming telephone line has an RJ-11 configuration, connect it to the RJ-11 on the control board, else use the 

two terminal positions marked "C.O."  

4.

The 

AES-2000

can be wired to operate a single door strike, or a door strike and an automatic door opener.  The 

doorstrike and door strike power supply should be wired to the terminal positions labeled "Door Strike 1". Both nor-

mally open and normally closed contacts are available.  

5.

If an automatic door needs a contact

closure, wire it to the terminal pos-
itions labeled "Door Strike 2". Once
again both normally open and norm-
ally closed contacts are available.  

6.

If the installation requires a postal 

lock, be sure it is a momentary style, 
and wire it to the terminal block pos-
itions labeled "Postal Lock". 

7.

After all the connections are made, 

close and lock the hinged panel.  

8.

The last step is to connect to A.C.  

power adapter to a wall outlet.  
When power is connected to the
system, the front display should 
show "Welcome!".

1

1

8

VIKING

Model:

 xxx

Viking Electronics

, Inc.

 (715)386-8861

1531 Industr

ial St., Hudson, 

WI 54016

S/N:

 XXXXXX

P/N:

 xxxxxxx

C.O. Line

or Analog

PABX/KSU

station

-or-

13.8V AC

Adapter

included

120V AC

Keyed Momentary or

Postal Lock Switch

Normally Closed Relay Contact

Normally Open Relay Contact

Doorstrike/Magnetic Lock

.5A @ 125V AC or
or 1A @ 30V AC maximum

Gate controllers do not 
typically require power.

.5A @ 125V AC or
or 1A @ 30V AC maximum

Gate controllers do not 
typically require power.

Normally Closed Relay Contact

Normally Open Relay Contact

Doorstrike/Magnetic Lock

AES-2000 Panel Rear View