background image

 

 
    Connecting the remote boot release 

When connecting the boot release wire a relay is required as the 
signal has a low current which can cause the boot release solenoid 
to operate ineffectively.  The diagram to the right shows how to 
wire both 4 pin & 5 pin relays. 
 

4 pin & 5 pin relays. 

a.)

 

Connect relay pins 86 & 87 to a +12v CONSTANT power source 

b.)

 

Connect alarms GRAY(-) boot release wire to relay pin 85. 

c.)

 

Connect boot r) terminal to relay pin 30. 
 

How it works: 

Relay 86 & 87 pins have a +12v supply  all the time, when the relay  
terminal 85 receives the (-) neg. signal from the alarm module it 
momentarily connects terminals 87 & 30 which powers the boot 
release solenoid to release the boot latch. 

 

 

www.viking-au.com/docs/acl-383-manual.pdf 

 

Содержание ACL-383V

Страница 1: ...ar two LONG chirps indicating it has stopped code learning mode LED STATUS INDICATIONS a ARMED LED flashes steady approximately 1x per second b DISARMED LED flashes fast to indicate 30 second auto arm mode turn IGN ON or open door to stop c VALET MODE LED is continuously ON does not flash TROUBLE SHOOTING ALARM SYSTEM WON T STOP non responsive to all remote buttons POSSIBLE CAUSE anti carjacking m...

Страница 2: ...4 pin 5 pin relays a Connect relay pins 86 87 to a 12v CONSTANT power source b Connect alarms GRAY boot release wire to relay pin 85 c Connect boot release terminal to relay pin 30 How it works Relay 86 87 pins have a 12v supply all the time when the relay terminal 85 receives the neg signal from the alarm module it momentarily connects terminals 87 30 which powers the boot release solenoid to rel...

Страница 3: ... active for 30 seconds or until ignition is turned on or system armed NB If pressing button 2 within 3 seconds of arming system won t disarm which can seem like a fault but you need to wait at least 3 seconds after arming before disarming SILENT ARMING DISARMING a Press button 3 once then press button 1 within 2 seconds to enter silent arming mode b Press button 3 once then press button 2 within 2...

Страница 4: ... 31 45 seconds LED will flash fast siren will chirp 1x every 2 seconds From 46 70 seconds LED will flash fast siren will chirp 1x every second After 70 seconds siren will sound parking lights flash continuously b After turning IGN OFF siren will sound parking lights flash continuously for 3 mins before stopping J3 DOOR LOCK UNLOCK TIMER 0 5 OR 3 5 SECONDS You can choose between 0 5 second or 3 5 s...