background image

27

26

64

˚

F

42

˚

F

ON

Hi/Low  Temp  Upper
Hi/Low  Temp  Lower

TruProtect

“Advanced” Function “Quick” Reference

SERVICE DIAGNOSTICS - DUAL ZONE

Solid Door Dual Zone Models:

Glass Door Dual Zone Models:

Place new control here when I get it from Ray

64

˚

F

42

˚

F

ON

Hi/Low  Temp  Upper
Hi/Low  Temp  Lower

F

Fu

un

nccttiio

on

n

F

Fu

un

nccttiio

on

n  A

Acccce

essss

S

Se

errvviicce

e  D

Diia

ag

gn

no

ossttiiccss

T

To

o  “

“E

En

ntte

err”

”  a

an

nd

d  “

“E

Exxiitt”

”  S

Se

errvviicce

e  D

Diia

ag

gn

no

ossttiiccss  m

mo

od

de

e,,  p

prre

essss  a

an

nd

d  h

ho

olld

d  tth

he

e

kke

eyyp

pa

ad

d  w

wh

hiille

e

p

prre

essssiin

ng

g  tth

he

e

kke

eyyp

pa

ad

d  ffo

ou

urr  ((4

4))  ttiim

me

ess  iin

n  ffiivve

e  ((5

5))  sse

ecco

on

nd

dss..  S

Se

errvviicce

e  D

Diia

ag

gn

no

ossttiiccss  m

mo

od

de

e

w

wiillll  a

au

utto

om

ma

attiicca

allllyy  e

exxiitt  a

afftte

err  ffiivve

e  ((5

5))  m

miin

nu

utte

ess  o

off  n

no

o  kke

eyyp

pa

ad

d  e

en

nttrryy..

D

Diissp

plla

ayy  E

Errrro

orr  C

Co

od

de

e  R

Re

effe

erre

en

ncce

e::

T

Th

he

e  m

miiccrro

op

prro

occe

esssso

orr  iin

n  tth

he

e  cco

on

nttrro

oll  cco

on

nttiin

nu

ua

allllyy  m

mo

on

niitto

orrss  ccrriittiicca

all  rre

effrriig

ge

erra

attiio

on

n  ssyysstte

em

m

cco

om

mp

po

on

ne

en

nttss  ffo

orr  p

prro

op

pe

err  o

op

pe

erra

attiio

on

n..  IIff  cco

om

mp

po

on

ne

en

ntt  p

pa

arra

am

me

ette

errss  e

exxcce

ee

ed

d  n

no

orrm

ma

all  o

op

pe

erra

attiin

ng

g

ssp

pe

ecciiffiicca

attiio

on

nss,,  tth

he

e  d

diissp

plla

ayy  w

wiillll  a

au

utto

om

ma

attiicca

allllyy  fflla

assh

h  tth

he

e  rre

essp

pe

eccttiivve

e  e

errrro

orr  cco

od

de

e  a

ass  ffo

ollllo

ow

wss::

P

Po

ow

we

err  lliin

ne

e  ffllu

uccttu

ua

attiio

on

nss  m

ma

ayy  cca

au

usse

e  a

an

n  e

errrro

orr  cco

od

de

e  tto

o  b

be

e  d

diissp

plla

ayye

ed

d  w

wiitth

h  n

no

o  p

prro

od

du

ucctt  ffa

au

ulltt..

T

Th

he

erre

effo

orre

e,,  tth

he

e  ffiirrsstt  ttiim

me

e  a

an

n  e

errrro

orr  cco

od

de

e  a

ap

pp

pe

ea

arrss,,  p

plle

ea

asse

e  cclle

ea

arr  tth

he

e  cco

od

de

e  b

byy  h

ho

olld

diin

ng

g

a

an

nd

d

p

prre

essssiin

ng

g

4

4  ttiim

me

ess..  IIff  tth

he

e  p

prro

od

du

ucctt  iiss  a

att  ffa

au

ulltt,,  tth

he

e  e

errrro

orr  cco

od

de

e  w

wiillll  a

ap

pp

pe

ea

arr  a

ag

ga

aiin

n,,  a

an

nd

d  yyo

ou

u

ssh

ho

ou

ulld

d  cco

on

ntta

acctt  yyo

ou

urr  D

De

ea

alle

err  o

orr  V

Viikkiin

ng

g  C

Cu

usstto

om

me

err  S

Se

errvviicce

e  tto

o  sscch

he

ed

du

ulle

e  sse

errvviicce

e  b

byy  a

a

q

qu

ua

alliiffiie

ed

d  tte

ecch

hn

niicciia

an

n..

ON 

OFF

SET

WARMER

COLDER

˚̊F/C

LIGHT

55

˚

F

13

˚

C

38

˚

F

4

˚

C

SA

ON 

OFF

SET

WARMER

COLDER

˚̊F/C

LIGHT

55

˚

F

13

˚

C

38

˚

F

4

˚

C

SA

E1

Compressor Error, (High/Low Amps)

Condenser Fan Error, (High/Low Amps)

Upper Compartment “Sensor A” Error, (Out-of-Range)

Lower Compartment “Sensor B” Error, (Out-of-Range)

E2

E3

E1

C

Co

on

nttrro

oll  C

Co

on

nffiirrm

ma

attiio

on

n//C

Co

om

mm

me

en

ntt

ON 

OFF

SET

WARMER

COLDER

˚̊F/C

LIGHT

55

˚

F

13

˚

C

38

˚

F

4

˚

C

SA

ON 

OFF

SET

WARMER

COLDER

˚̊F/C

LIGHT

55

˚

F

13

˚

C

38

˚

F

4

˚

C

SA

ON 

OFF

SET

WARMER

COLDER

˚̊F/C

LIGHT

55

˚

F

13

˚

C

38

˚

F

4

˚

C

SA

S

Se

errvviicce

e  D

Diia

ag

gn

no

ossttiiccss  M

Mo

od

de

e  e

en

na

ab

blle

ess  sse

errvviicce

e  tte

ecch

hn

niicciia

an

nss  tto

o  iid

de

en

nttiiffyy  tth

he

e  ffiirrm

mw

wa

arre

e  a

an

nd

d  sso

offttw

wa

arre

e  vve

errssiio

on

nss,,  tte

esstt  sstta

attu

uss  o

off

“m

mo

od

de

ell  ssp

pe

ecciiffiicc”

”  ssyysstte

em

m  cco

om

mp

po

on

ne

en

nttss  a

an

nd

d  sse

en

nsso

orrss  a

an

nd

d  cch

ha

an

ng

ge

e  sstta

atte

e  o

off  cco

om

mp

po

on

ne

en

nttss  w

wh

he

erre

e  a

ap

pp

plliicca

ab

blle

e,,  ((ii..e

e..  --  cco

om

mp

prre

esssso

orr

o

on

n//o

offff,,  e

ettcc......))..  W

Wh

hiille

e  iin

n  S

Se

errvviicce

e  D

Diia

ag

gn

no

ossttiiccss  M

Mo

od

de

e,,  tte

essttss  a

arre

e  iin

nccrre

em

me

en

ntte

ed

d  b

byy  p

prre

essssiin

ng

g  tth

he

e              kke

eyyp

pa

ad

d  a

an

nd

d  ssp

pe

ecciiffiicc

cco

om

mp

po

on

ne

en

ntt  sstta

atte

ess  cca

an

n  b

be

e  cch

ha

an

ng

ge

ed

d  tto

o  “

“O

ON

N”

”  a

an

nd

d  “

“O

OF

FF

F”

”  b

byy  p

prre

essssiin

ng

g  tth

he

e                    a

an

nd

d

kke

eyyp

pa

ad

dss  rre

essp

pe

eccttiivve

ellyy..  T

Th

he

e

ffo

ollllo

ow

wiin

ng

g  cco

om

mp

po

on

ne

en

ntt  tte

essttss  a

arre

e  a

avva

aiilla

ab

blle

e::

Test #

Component Description

OK

Off/Open

On/Shorted

0

Temp Sensor, Upper

1

Temp Sensor, Lower

2

Compressor

n/a

3

Condenser Fan

n/a

4

Compartment Fan, Upper

n/a

5

Compartment Fan, Lower

n/a

6

Heater/Fan Assembly, Upper

n/a

7

Heater/Fan Assembly, Lower

n/a

8

Door Sense

n/a

Available Status Indicators

0 -

1 -

0 0

NOTE: The Door Sense is located between the Upper Compartment display and the ON/OFF key and can be tested
with any magnet.

ON 

OFF

SET

PRESS AND HOLD

magnet sense area

40

˚

F

1 0

2 0

3 0

4 0

5 0

6 0

7 0

8 0

0 1

1 1

2 1

3 1

4 1

5 1

6 1

7 1

8 1

ON 

OFF

SET

WARMER

COLDER

˚̊F/C

55˚

F

LIGHT

13˚

C

38˚

F

 4˚

C

 SA

ON 

OFF

SET

WARMER

COLDER

˚̊F/C

55˚

F

LIGHT

13˚

C

38˚

F

 4˚

C

 SA

Содержание 24"W

Страница 1: ...ation 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com Viking Use Installation Guide Un...

Страница 2: ...and grounding A 115V 60 Hz 15 amp fused electrical supply is required NOTE Time delay fuse or circuit breaker is recommended not used by anyone unable to operate it properly used only for its intended...

Страница 3: ...C 60 Hz Maximum amps 3 0 Approximate Shipping Weight 110 lbs 49 5 kg 23 5 8 60 0 cm 21 3 16 53 8 cm 30 3 4 78 1 cm 14 3 4 37 5 cm 14 3 4 37 5 cm 14 3 4 37 5 cm 34 1 4 87 0 cm min to 35 88 9 cm max wit...

Страница 4: ...aximum amps 3 3 Approximate Shipping Weight Single Zone 140 lbs 63 2 kg Dual Zone 170 lbs 76 5 kg SPECIFICATIONS DIMENSIONS DESIGNER 24 W Models Basic Electric Data 115 VAC 60 Hz Maximum amps 3 3 Appr...

Страница 5: ...side to side Use a 5 32 allen wrench for this procedure See Figure 1 below Figure 1 9 32 7 mm Door must be parallel to top and sides of refrigerator Hinge adaptor screws Loosen these to adjust door on...

Страница 6: ...6 1 cm Table A Glass Door Models 1 23 32 38 8 cm Material Type Hardwood 3 32 2 4 mm Diameter Pilot Hole Softwood 5 64 2 0 mm Diameter Pilot Hole Table B 8 Wood Screw Step 7 Mark and drill lock hole Lo...

Страница 7: ...hours before plugging the unit in CUSTOM WOOD FRAME INSTALLATION DFUW Model cont Clearance hole through door gasket channel 8 Wood Screw Back of door Figure 5 Step 9 Secure overlay panel to the door W...

Страница 8: ...screwdriver and plug the light unit in Plug Hex head screw Light assembly Green ground wire Hex head screw DANGER ELECTRICAL SHOCK HAZARD Failure to to disconnect the power cord when changing the lig...

Страница 9: ...LIGHT 55 F 13 C 38 F 4 C SA ON OFF SET WARMER COLDER F C LIGHT 55 F 13 C 38 F 4 C SA ON OFF SET WARMER COLDER F C LIGHT 55 F 13 C 38 F 4 C SA 17 Glass Door Single Zone Models ON OFF SET PRESS AND HOL...

Страница 10: ...l TruProtect must be Enabled See Disable Enable TruProtect described below Close door to reset DOOR AJAR Alarm Press the key to reset all other alarms Press and hold the key for five 5 seconds to enab...

Страница 11: ...e single bottle roll out rack allows easy view and access of your inventory without disturbing other bottles Front Bottles Necks Facing Rear Rear Bottles Necks Facing Front LOADING RECOMMENDATIONS 24...

Страница 12: ...ger when maintained properly and kept clean Condenser The condenser tubing inside the cabinet does not require frequent cleaning however satisfactory cooling depends on adequate ventilation over the c...

Страница 13: ...o ow we er r O On n R Re es se et t P PO OR R i i e e d di is sc co on nn ne ec ct t a an nd d r re ec co on nn ne ec ct t t th he e p po ow we er r s su up pp pl ly y t to o u un ni it t E Ex xi it t...

Страница 14: ...on nt ta ac ct t y yo ou ur r D De ea al le er r o or r V Vi ik ki in ng g C Cu us st to om me er r S Se er rv vi ic ce e t to o s sc ch he ed du ul le e s se er rv vi ic ce e b by y a a q qu ua al l...

Страница 15: ...reach of contract or otherwise Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you Owner shall...

Страница 16: ...proper installation improper operation or repair or service to the product by anyone other than an authorized Viking Range Corporation service agency or representative Warranty shall not apply to dama...

Отзывы: