background image

1600A Series

1600A Series

ADA Compliant

Emergency Phones

September 10, 2015

ADA* Compliant Emergency Phones with 

Built-In Digital Voice Announcer

•  New Automatic Noise Canceling (ANC) feature for proper operation 

in noisy environments

•  Meets the latest ASME A17.1 code when used with the optional 

LV-1K

Line Verification Panel, see 

DOD# 246

•  Meets ADA requirements for Emergency Phones:

- Automatically lights the “Call Connected” LED
- Transmits a unique location I.D. code or voice announcement
- Grade 2 Braille label for the visually impaired

•  Non-volatile digital voice announcer with 16 seconds of voice memory
•  Advanced call progress detection
•  Handsfree operation
•  Phone line powered
•  Non-volatile memory (no batteries required)
•  Marine grade 316 stainless steel prevents corrosion on stainless models
•  Dials up to 5 emergency numbers
•  

E-1600-20A

and 

E-1600-52A 

dial up to 3 non-emergency “INFO” #’s 

•  Cycles through backup phone numbers on busy or no-answer
•  Optional Enhanced Weather Protection (EWP), EWP products are 

designed to meet IP66 Ingress Protection Rating, see 

DOD# 859

•  Hangs up on CPC, silence, busy signal, dial tone, time-out or touch

tone command

•  Programmable to auto-answer on incoming calls
•  Remotely programmable 
•  Extended temperature range (-15°F to 130°F)
•  9 different chassis or board only available 
•  Available in 42” tall tower phone model 

E-1600A-BLT-EWP

(

DOD# 217

)

•  Central Station Monitoring capability (dials 2 numbers)
•  Optional 

PB-100

Polling System available (

DOD# 232

)

•  Optional 

BLK-3-EWP

strobe light kit available (

DOD# 653

)

•  Optional 

LC-6

Six Port Concentrator available (

DOD# 245

)

•  Optional 

LV-1K

Line Verification Panel available (

DOD# 246

)

•  Optional 

E-1600A-MK-GNP

Pedestal Mounting Kit (

DOD# 227

)

•  Optional 

PB-1

Panic Button Kit (

DOD# 233

)

P

P

r

r

a

a

c

c

t

t

i

i

c

c

e

e

T

T

E

E

L

L

E

E

C

C

O

O

M

M

S

S

O

O

L

L

U

U

T

T

I

I

O

O

N

N

S

S

F

F

O

O

R

R

T

T

H

H

E

E

2

2

1

1

S

S

T

T

C

C

E

E

N

N

T

T

U

U

R

R

Y

Y

TECHNICAL

TECHNICAL

F

F

e

e

a

a

t

t

u

u

r

r

e

e

s

s

E-1600-45A

K-1600-EHFA

E-1600A

E-1600-02A

E-1600-03B

E-1600-20A

Power:  

Telephone line powered. Minimum 24V DC talk battery voltage,

with a minimum loop current of 20mA loop. Loop current may be boosted
on low current lines with a Viking Model 

TBB-1B

talk battery booster, see

DOD# 632

.

Dimensions: 

See Installation and Specifications

Operating Temperature: 

-26° C to 54° C (-15° F to 130° F)

Humidity - Standard Products:

5% to 95% non-condensing

Humidity - EWP Products:

Up to 100%

S

S

p

p

e

e

c

c

i

i

f

f

i

i

c

c

a

a

t

t

i

i

o

o

n

n

s

s

* Americans with Disabilities Act of 1992 contains federal reg-

ulations regarding elevator telephones (Public Law 101-336).

•  Elevators
•  Parking ramps/lots
•  Emergency pool phones
•  ATM machines
•  Area of refuge locations
•  Lobbies
•  Entryways
•  Campus emergency stations
•  Roadside emergency stations
•  Stadiums
•  Convention centers
•  Silent holdup alarm dialer using optional Panic Button Kit

A

A

p

p

p

p

l

l

i

i

c

c

a

a

t

t

i

i

o

o

n

n

s

s

CAUTION - When installing on an analog extension of a phone system:

Some phone systems do not conform to analog telecom standards and might
not be compatible with the 1600A Series emergency phones. For a detailed
description of the telephone line specifications required for any of the 1600A
Series phones, see 

DOD# 869

.

E-1600-55A

E-1600-30A

E-1600-65A

E-1600-60A

The 

1600A Series

ADA Compliant Emergency Phones are designed

to provide quick and reliable handsfree communication for any stan-
dard analog telephone line or analog phone system station port.  All

1600A Series

phones meet ADA requirements for elevator/ emer-

gency telephones, and can be programmed from any Touch Tone
phone. The phones can dial up to 5 programmable emergency num-
bers, as well as 2 central station num-
bers. In addition, the 

E-1600-20A

and

E-1600-52A

feature a second "

INFO

"

button that will dial up to 3 non-emer-
gency numbers.

The 

1600A Series

phones can be pro-

grammed to automatically deliver a
digital announcement to identify the location of the emergency call.  Alternatively, a DTMF Touch Tone code may also be delivered.
A “Call Connected” LED can be initiated manually or automatically.  All programming parameters, including phone numbers and
location numbers, are stored in non-volatile E

2

memory.  All units are phone line powered, requiring no batteries or external power

and are compatible with common Central Station Monitoring equipment.

For outdoor installations where the unit is exposed to precipitation or condensation, select 

1600A Series

phones are available with

Enhanced Weather Protection (

EWP

).  EWP products feature foam rubber gaskets and boots, sealed connections, gel-filled butt

connectors, as well as urethane or thermal plastic potted circuit boards with internally sealed, field-adjustable trim pots and DIP
switches for easy on-site programming. For more information, see

DOD# 859

.

Содержание 1600A Series

Страница 1: ...perature 26 C to 54 C 15 F to 130 F Humidity Standard Products 5 to 95 non condensing Humidity EWP Products Up to 100 S Sp pe ec ci if fi ic ca at ti io on ns s Americans with Disabilities Act of 1992 contains federal reg ulations regarding elevator telephones Public Law 101 336 Elevators Parking ramps lots Emergency pool phones ATM machines Area of refuge locations Lobbies Entryways Campus emerge...

Страница 2: ...connected This is to avoid damaging the equipment caused by local lightning strikes and other electrical surges PART 15 LIMITATIONS This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial ...

Страница 3: ... ways etc Suggested Hardware 6 8 x 3 4 flat head phillips sheet metal type A screws not included Optional Enhanced Weather Protection EWP The optional EWP products feature foam rubber gaskets and boots sealed con nections gel filled butt connectors as well as urethane or thermal plastic potted circuit boards See DOD 859 Note When mounting outside to rough or uneven surfaces brick stucco etc apply ...

Страница 4: ...d click on Spare Parts to order these rough in boxes E E 1 16 60 00 0 3 30 0A A o op pt ti io on na al l E EW WP P a av va ai il la ab bl le e Important The E 1600 20A will NOT mount to a standard double gang box Note Peel off paper liner and adhere gasket to the back of the faceplate centering it over the four corner mounting holes Optional Enhanced Weather Protection EWP The optional EWP product...

Страница 5: ...ar the bot tom of the boot to allow for drainage PC Board Mounting Side View Optional Enhanced Weather Protection EWP The optional EWP products fea ture foam rubber gaskets and boots sealed connections gel filled butt connectors as well as urethane or thermal plastic potted circuit boards See DOD 859 Note This is a 1600A parts kit without chassis Shipping Weight 45 kg 1 lb Connections Gel filled b...

Страница 6: ... a av va ai il la ab bl le e Black Black Clear Spacer Red 5mm Retaining Lens Round LED Ring 4 Countersunk holes for mounting the dust cover 2 0 Diameter 2 25 3 77 4 50 5 0 5 0 4 50 1 76 3 625 Typ 0 25 Typ 4 0 25 diameter clearance holes for mounting the unit to the back side of a finished panel 0 25 Diameter 4 6 32 x 3 4 stainless steel flat head T 10 Torx Security Screws and Drive Bit included fo...

Страница 7: ...gram enter the desired speed dial number followed by the location number 00 04 To clear a speed dial location simply enter the memory location 00 04 alone The 1600A series phone is factory set with no speed dial number programmed 1 Emergency Speed Dial Numbers memory locations 00 04 Note Up to 20 digits can be stored in each dial position Special features such as pause mode change touch tone Q and...

Страница 8: ... This feature selects the maximum length of time that calls can be connected Programmable in increments of 1 minute up to a maximum of 9 minutes Touch Tones 1 9 Program 0 in this location to disable the call length time out With the call length dis abled the 1600A series phone must rely on a CPC signal busy signal silence or return to dial tone to hang up Use chart at the right Note The factory de...

Страница 9: ...phones have a built in non volatile digital voice announcer that may be used to identify the location of the emer gency phone call The 16 seconds of digital record time is recorded remotely from a Touch Tone phone Programming options are as follows Dial A B C D E F 1 7 Factory Default Setting 0 0 1 2 1 0 Two Digit Announcement Delay Repeat Announcement Setting Hang up on Return to Dial Tone Double...

Страница 10: ... the ON position otherwise the 1600A Series phone will only call Viking Technical Support instead of your programmed emergency number Switch A ON OFF Description Normal audio detection Increase audio detect sensitivity for low level lines Useful in applications in which voice or busy signals have trouble breaking over the speaker Switch B ON OFF When attempting to program the 1600A Series emergenc...

Страница 11: ...er the kiss off will hang up and redial the number in position 06 for two way voice communication Notes If only a central station is to be dialed the cen tral station phone number must be preprogrammed in memory location 05 and memory locations 00 04 must be cleared 2 Central Station Formats The following examples explain the receiver formats and how to properly program memory location 20 Each for...

Страница 12: ...nformation contained in this document is subject to change without notice Viking Electronics and its affiliates and or subsidiaries assume no responsibility for errors and omissions contained in this information Revisions of this document or new editions of it may be issued to incorporate such changes DOD 215 Printed in the U S A P Pr ro od du uc ct t S Su up pp po or rt t L Li in ne e 7 71 15 5 3...

Отзывы: