Viking 06932B Скачать руководство пользователя страница 5

MICROFAST

®

 

QUICK RESPONSE 

PENDENT SPRINKLER 

VK3311 (K4.2)

TECHNICAL DATA

Page 5 of 5

Form No. F_061914    19.02.21    Rev 19.1

The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058

Telephone: 269-945-9501  Technical Services: 877-384-5464  Fax: 269-818-1680  Email: [email protected]

Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com.

Figure 4:  Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons

Figure 3:  Sprinkler Dimensions with a Standard Escutcheon

1/2”

(10 mm)

NPT

2-1/4” 

(57 mm)

Installed with a standard 

1/8” surface-mounted 

escutcheon

Ceiling Opening Size:

2-5/16” (59 mm) minimum

2-1/2” (64 mm) maximum

1-3/4” 

(45 mm)

Max.

2-1/8” 

(54 mm)

1-1/8” 

(29 mm)

Min.

2”” 

(51 mm)

Max.

1-1/8” 

(29 mm)

Min.

2-1/8” 

(54 mm)

Ceiling Opening Size:

2-5/16” (59 mm) minimum

2-1/2” (64 mm) maximum

Installed with a 

Model E-1 Recessed 

Escutcheon

Installed with a Model 

E-2 Thread-on  Recessed 

Escutcheon

Replaces form F_061914 Rev. 17.2.P65

(Removed F-1 Escutcheon.)

Содержание 06932B

Страница 1: ...Casting Brass UNS C84400 Deflector Brass UNS C26000 Bushing Brass UNS C36000 Bulb Glass nominal 3 mm diameter Belleville Spring Sealing Assembly Nickel Alloy coated on both sides with PTFE Tape Screw...

Страница 2: ...s the heat sensitive liquid in the glass bulb expands causing the glass to shatter releasing the pip cap and sealing spring assembly Water flowing through the sprinkler orifice strikes the sprinkler d...

Страница 3: ...Polyester and Black PTFE Footnotes 1 The sprinkler temperature rating is stamped on the deflector 2 Based on NFPA 13 Other limits may apply depending on fire loading sprinkler location and other requi...

Страница 4: ...te Polyester4 and Black Polyester4 2 Brass and Chrome Footnotes 1 Base part number shown For complete part number refer to Viking s current price schedule 2 Metric K factor measurement shown is when p...

Страница 5: ...igure 4 Sprinkler Dimensions with the Model E 1 and E 2 Recessed Escutcheons Figure 3 Sprinkler Dimensions with a Standard Escutcheon 1 2 10 mm NPT 2 1 4 57 mm Installed with a standard 1 8 surface mo...

Страница 6: ...tall sprinklers onto piping at the floor level Install sprinklers after the piping is in place to prevent mechanical damage DO NOT allow impacts such as hammer blows directly to sprinklers or to fitti...

Страница 7: ...CAPS MUST BE REMOVED FROM SPRINKLERS BEFORE PLACING THE SYSTEM IN SERVICE Figure 1 Sprinkler shield being removed from a pendent sprinkler Figure 2 Sprinkler cap being removed from a pendent sprinkle...

Страница 8: ...these sprinklers NOTE The protective cap is temporarily removed during installation and then placed back on the sprinkler for protection until finish work is completed Do not over tighten the sprinkle...

Страница 9: ...the corrosion resistant properties of the sprinkler Use care when locating sprinklers near fixtures that can generate heat Do not install sprinklers where they would be exposed to temperatures exceed...

Страница 10: ...tion of fire protection products are provided herin as they relate to legally mandated jurisdictional regions WARNING STATE OF CALIFORNIA USA Installing or servicing fire protection products such as s...

Отзывы: