7  Glossary 

This document incorporates many industry and device-specific words. Use the 
following list to define a variety of terms and acronyms.  
 

Term 

Definition 

ATA 

Advanced Technology Attachment 

ATAPI 

Advanced Technology Attachment Packet Interface 

BER 

Bit error rate, or percentage of bits that have errors relative to the total number of bits 
received 

DIPM 

Device Initiated Link Power Management. The ability of the device to request SATA link 
power state changes. 

DMA 

Direct Memory Access 

eMLC 

Enterprise Multi-Level Cell 

EXT 

Extended 

FP 

First Party 

GB 

Giga-byte defined as 1x10

9

 bytes  

HDD 

Hard Disk Drive 

Hot Plug 

A term used to describe the removal or insertion of a SATA storage drive when the 
system is powered on. 

IOPS 

Input output operations per second 

LBA 

Logical Block Address 

MB 

Mega-bytes defined as 1x10

6

 bytes  

MLC 

Multi-Level Cell 

MTBF 

Mean Time Between Failures 

NCQ 

Native Command Queuing. The ability of the SATA hard drive to queue and re-order 
commands to maximize execution efficiency. 

NOP 

No Operation 

OS 

Operating System 

Port 

The point at which a SATA drive physically connects to the SATA controller. 

RMS 

Root Mean Squared 

RPM 

Revolutions Per Minute 

SAS 

Serial Attached SCSI 

SATA 

Serial ATA 

SFF 

Small Form Factor 

SLC 

Single Level Cell  

S.M.A.R.T. 

Self-Monitoring, Analysis and Reporting Technology: an open standard for developing 
hard drives and software systems that automatically monitors a hard drive’s health and 
reports potential problems. 

SSD 

Solid-State Drive 

 

 

Содержание VRFEM2008GZIQSTH

Страница 1: ...Page 1 of 34 www vikingtechnology com SATA 6Gb s Industrial mSATA Manual mSATA mini SATA MO 300 is a non volatile solid state storage device delivering Serial ATA performance reliability and ruggednes...

Страница 2: ...FEM2xxxxZIxx Viking Technology Revision A Page 2 of 34 www vikingtechnology com Revision History Date Revision Description Checked By 3 28 17 Initial Release based on PSFEM2xxxxZxxx_B Add VRFEM2016GZI...

Страница 3: ...term or condition of any kind either expressed or implied including but not limited to expressed and implied warranties of merchantability fitness for a particular purpose and non infringement While t...

Страница 4: ...terface Temp User GB Client Ent NAND VRFEM2008GZIQSTH MO 300 40to 85 c 8 Client TSB 24nm H die SLC VRFEM2016GZIRSTH MO 300 40to 85 c 16 Client TSB 24nm H die SLC Notes 1 Higher capacity points may be...

Страница 5: ...Manual 3 28 2017 PSFEM2xxxxZIxx Viking Technology Revision A Page 5 of 34 www vikingtechnology com Product Picture s...

Страница 6: ...ins sophisticated provisions to protect firmware and data from corruption due to unexpected power loss However an Industrial SSD by industry definition does not contain on board capacitance Should pow...

Страница 7: ...TE Command 15 2 4 Electrical Characteristics 15 2 4 1 Absolute Maximum Ratings 15 2 4 2 Supply Voltage 16 2 4 3 Power Consumption 16 2 5 Environmental Conditions 16 2 5 1 Temperature and Altitude 16 2...

Страница 8: ...on Overlay Command Set 23 5 1 4 General Purpose Log Command Set 23 5 1 5 Host Protected Area Command Set 24 5 1 6 Power Management Command Set 24 5 1 7 Security Mode Feature Set 24 5 1 8 Identify Devi...

Страница 9: ...bration Specifications_______________________________________ 17 Table 2 9 Reliability Specifications _______________________________________________ 17 Table 4 1 Mini PCIe Connector Pin Signal Defini...

Страница 10: ...environments such as shock vibration humidity altitude ESD and extreme temperatures 1 1 Features The SSD delivers the following features Offers seamless SATA Revision 3 0 interface support for SATA u...

Страница 11: ...PSFEM2xxxxZIxx Viking Technology Revision A Page 11 of 34 www vikingtechnology com 1 2 Block Diagram Figure 1 1 High Level Block Diagram Notes 1 Support for up to 2 channels and 2 CE in the NAND Flas...

Страница 12: ...n revision 3 0 that supports SATA up to 6Gb s The SATA interface connects the host computer to the SSD subsystem The SATA interface runs at a maximum speed of 6 Gbps Giga bits per second If the host c...

Страница 13: ...acity Flash Structure Performance1 CrystalDiskMark ATTO Read Write Read Write MB s MB s MB s MB s 14 16GB 16GBx1 BGA TSB H die SLC TBD TBD TBD TBD 30 32GB 32GBx1 BGA TSB H die SLC TBD TBD TBD TBD 60 6...

Страница 14: ...TBD 512GB 15nm TBD TBD Notes 1 Performance measured using Iometer 08 with queue depth set to 32 2 Write Cache enabled with DDR cache 3 Random IOPS cover the entire range of legal logical block address...

Страница 15: ...d Power Loss records the number of non graceful power cycle events Table 2 3 STANDBY IMMEDIATE Timing Power Cycle Endurance Min Max Unit STANDBY IMMEDIATE to WE completed 72 9 ms Notes From Standby Im...

Страница 16: ...ie SLC TBD TBD TBD 60 64GB 32GBx2 BGA TSB H die SLC TBD TBD TBD 120 128GB 64GBx2 BGA TSB H die SLC TBD TBD TBD 240 256GB 128GBx2 BGA TSB H die SLC TBD TBD TBD 480 512GB 256GBx2 BGA TSB H die SLC TBD T...

Страница 17: ...ystem EMI FCC compliance 2 6 Reliability Table 2 9 Reliability Specifications Parameter Description MTBF Over 2 000 000 hours ECC 72 bit per 1KByte Read Endurance Unlimited Write Endurance SLC TBW 16G...

Страница 18: ...Manual 3 28 2017 PSFEM2xxxxZIxx Viking Technology Revision A Page 18 of 34 www vikingtechnology com Figure 3 1 Dimensions...

Страница 19: ...Manual 3 28 2017 PSFEM2xxxxZIxx Viking Technology Revision A Page 19 of 34 www vikingtechnology com Notes All dimensions are in millimeters...

Страница 20: ...Path P5 Reserved No Connect P6 Reserved No Connect P7 Reserved No Connect P8 Reserved No Connect P9 GND Return Current Path P10 Reserved No Connect P11 Reserved No Connect P12 Reserved No Connect P13...

Страница 21: ...Connect Vendor Specific Manufacturing Pin 2 P46 Reserved No Connect P47 Optional No Connect Vendor Specific Manufacturing Pin 2 P48 Reserved No Connect Reserved P49 DAS Device Activity Signal P50 GND...

Страница 22: ...diate E1h Set multiple mode C6h Initialize drive parameters 91h Sleep E6h Read buffer E4h Smart B0h Read DMA w o retry C9h Standby E2h Read DMA w retry C8h Standby immediate E0h Read DMA Ext 25h Write...

Страница 23: ...nsisting of Download Microcode Executive Device Diagnostics Flush Cache Identify Device NOP optional Read Buffer optional Read DMA Read Multiple Read Sector s Read Verify Sector s Seek Set Features Se...

Страница 24: ...tional Set Max Set Password optional Set Max Unlock optional 5 1 6 Power Management Command Set SSD supports the Power Management command set consisting of Check Power Mode Idle Idle Immediate Sleep S...

Страница 25: ...20 ASCII characters 20 21 X 0000h Retired 22 X 0000h Obsolete 23 26 F Varies Firmware revision 8 ASCII characters 27 46 F Varies Model number xxxxxxxx 47 F 8010h 7 0 Maximum number of sectors transfer...

Страница 26: ...set feature supported extension 85 V 3469h Command set feature enabled 86 V BC01h Command set feature enabled 87 V 6063h Command set feature default 88 V 003Fh Ultra DMA Modes 89 F 001Eh Time require...

Страница 27: ...FA 168 F 3h 2 5 inch 4h 1 8 inch 5h 1 8 inch Device Nominal Form Factor 169 F 0001h DATA SET MANAGEMENT command is supported 170 173 F 0h Additional Product Identifier 174 175 0h Reserve 176 205 V 0h...

Страница 28: ...on that may be used to analyze drive health SATA drives provide Self Monitoring Analysis and Reporting Technology SMART features that include monitoring and storing critical performance and calibratio...

Страница 29: ...mmand Set Value hex Command 00 CF Reserved D0 S M A R T read attributes D1 S M A R T read threshold D2 S M A R T enable disable attribute autosave D3 S M A R T save attribute values D4 S M A R T execu...

Страница 30: ...l Count B6h Erase Failure Block Count BBh Reported Uncorrectable Errors ECC fail count 4bytes 01h only 1 bytes C0h Unexpected Power Loss Count C2h N A C7h Number of accumulated CRC Error read write da...

Страница 31: ...0 0 0 00h B6h 32h 00h 00h 00h Total erase bad blocks count 0 0 0 00h BBh 03h 00h 00h 00h Total ECC error count 0 0 0 00h C0h 12h 00h 64h 64h number of accidental power loss count 0 0 0 00h C2h N A N...

Страница 32: ...causes the SSD to initiate the collection of S M A R T data in an off line mode and then preserves this data across power and reset events Supported subcommands include those shown in the table below...

Страница 33: ...specification with regard to supported commands SSD s support the following features that are unique to the SATA specification 5 2 1 Native Command Queuing NCQ SSD s support the Native Command Queuin...

Страница 34: ...Hard Disk Drive Hot Plug A term used to describe the removal or insertion of a SATA storage drive when the system is powered on IOPS Input output operations per second LBA Logical Block Address MB Meg...

Отзывы: