spaTouch BP System
2019 Owner’s Manual
Страница 1: ...spaT ouch BP System 2019 Owner s Manual ...
Страница 2: ...nstructions 10 Features found on various Viking models 11 Topside Control Instructions all two pump systems 12 Spa Jets and Air Controls 15 Filling Directions Stereo Operation 14 Vibrosonic Jet Operation 14 Fill the Spa With Water 14 Skimmer Side Filter 15 Add Start Up Chemicals 15 Maintenance 16 Spa Draining 16 Spa Surface Care 17 Long Term Storage 17 Pillow Maintenance 17 Filter Cleaning 18 Spa ...
Страница 3: ...ter flow created by the pump Should the need arise to replace the suction fittings or the pump be sure that the flow rates are compatible Never operate the spa if the suction fittings are broken or missing Never replace a suction fitting with one rated less than the flow rate marked on the original fitting 4 DANGER Risk of Accidental Drowning Extreme Caution must be exercised to prevent unauthoriz...
Страница 4: ...edication before or during spa use may lead to unconsciousness with the possibility of drowning d Persons suffering from obesity or with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a spa e Persons using medication should consult a physician before using a spa since some medication may induce drowsines...
Страница 5: ... to the system at the main power source breaker NOTE A READILY ACCESSIBLE DISCONNECTING MEANS SHALL BE PROVIDED DURING INSTALLATION SAVE THESE INSTRUCTIONS PERSONAL SAFETY PRECAUTIONS 1 Please use the spa when others are present 2 Children should have spa access only with the permission and supervision of an adult 3 To reduce the risk of child drowning keep the spa filter clean and unclogged Do no...
Страница 6: ...r dirt Any settling surface will put an uneven pressure and tension to the spa structure and may void the warranty BALCONIES AND DECK REQUIREMENTS Decking must be constructed to support 85 pounds per sq ft Balconies must be constructed to meet current state and local codes Gates must be self closing and self latching ELECTRICAL REQUIREMENTS NOTE Name badge on rub rail indicates equipment location ...
Страница 7: ...220 VOLT BP601 Power System 6 Green ground connection located on left side of control panel WHITE BLACK RED GREEN ...
Страница 8: ...GFCI WIRING INSTALLATION 220V BP601 Power System 7 ...
Страница 9: ...from current source to spa and the current rating as stated on the ID label that is attached to the equipment control enclosure 5 All wiring installed in conduit must be approved for usage by state and local codes The conduit must terminate at the electrical access compartment either from the bottom of the spa or through a hole in the side panel of the spa SPA STARTUP DIRECTIONS All Viking Spas re...
Страница 10: ...601 It is very important to make sure that the spa is filled at least 3 4 way up the skimmer opening Make sure the gate valves are in the open or up position WARNING Do not run spa with gate valves closed or run pump with no water circulating in spa for long periods Damage could occur to the spa equipment 9 BP601 System Installed in Viking 3 Aurora 2 Aurora 3 Royale Regal Royale ETS Regal ETS All ...
Страница 11: ...PSIDE CONTROL INSTRUCTIONS Operating Instructions For operating instructions please type the following into your web browser http vikingspas com ftp 2018spatouchmanual pdf OR click on the QR code below 10 ...
Страница 12: ...with an LED light system This light ing which encompasses the interior of the spa is also incorporated into the light in the foot well of these models The LED Lighting system consists of a 7 position controller The first time the light is turned on it will begin to display all 7 colors available in an automatic rotating sequence Each time you sequence the light on off all colors will be displayed ...
Страница 13: ...To remove jet insert turn jet face counter clockwise to the shut off point Continue turning until the jet unscrews from body To rein stall the jet insert jet into body and turn clockwise until the jet stops AirX Jet Option If installed these red jets will be controlled using the red matching air control pictured 12 Twin Adjustable Roto Directional Roto Poly Rotational and Directional Mini Directio...
Страница 14: ...f the lounger Turn the valve to activate the jet Note this valve directs one of the pumps and will effect the flow this pump used to power other jets in the spa Due to the substantial amount of water pressure when the Turbo Jet is operating you must turn the pump to the off or low speed cycle position before attempting to rotate the jet face AIR CONTROLS Air controls are adjusted by rotating the t...
Страница 15: ...spa b Remove filter element c Using a garden hose place hose in filter chamber for filling Do not fill higher than three quarters of the way up the skimmer opening d We DO NOT recommend the use of softened water due to the potential harm of damaging equipment e As water level rises check inside equipment compartments for water leaks It may be necessary to tighten loose unions and or fittings f Mak...
Страница 16: ...ratic heating of the spa A starving pump will degrade performance result in dirty or murky water and may cause the heater to malfunction ADD START UP CHEMICALS Ask your spa retailer to HELP you set up a chemical maintenance program The importance of chemical balance in your spa cannot be overem phasized SANITIZING Please refer to your dealer supplied sanitizing recom mendations for your start up p...
Страница 17: ...odels 1 Twist cap off and attach a garden hose to the opening 2 Turn the outside body counter clockwise until it stops 3 Pull on the drain that the hose is connected to until you hear a pop 4 Drain the spa 5 Reverse this procedure to shut the water off Note the drain will not remove all of the water in the spa You may have to remove a small amount of water by hand DRAIN LOCATIONS Water Gate Valve ...
Страница 18: ...he piping is removed use a wet dry shop vac to vacuum water from both the pump side and the heater side openings Once all water is removed from these lines we also recom mend that you place the vacuum over each jet and the suction fittings and vacuum any remaining water that may be trapped in these lines You may now reinstall the piping assembly that was removed earlier and reinstall the pump plug...
Страница 19: ...arranty FILTER CLEANING Remove filter face cover by pulling straight up and slightly toward the spa on front plate face cover As shown below Remove access bas ket and unscrew filter cartridge s from housing To reinstall weir door assembly door must be placed through throat of skimmer prior to slid ing assembly into place Refer to filter cleaning procedure for Viking IP Viking 2P Viking 3 on previo...
Страница 20: ...download the spatouch owners manual and refer to page 15 to adjust filtration Viking recommends each filtration cycle to run for 4 hours for a com bined 8 hour daily period of time to provide adequate ozonation pro vided there is proper chemical balance in the spa NOTE Please Do Not attempt to disassemble ozonator if it becomes inoperable Ozonators contain no user serviceable parts Please contact ...
Страница 21: ...lons Viking 1P 240 Gallons Viking 2P Viking 3 250 Gallons Aurora P P 3 210 Gallons Royale P P Royale ETS 270 Gallons Regal P P Regal ETS 290 Gallons Legacy 320 Gallons Legend 300 Gallons Heritage 370 Gallons Tradition 390 Gallons 20 ...
Страница 22: ...ance needs pH Up Test water add pH Up pH irritation rashes to be corrected pH pH Down Down or Total A as needed allergies total alkalinity Total A Excessive chlorine or Add fresh water and or wait bromine a day re test sanitizer level Excessive foam Build up of body oils Spa Foam Away Add Spa Foam Away to cosmetics and Spa See Clear foamy area then add 1oz contaminants Spa See Clear pH Total Alkal...
Страница 23: ...ers of the way on the skimmer opening Is there proper water flow Solution Make sure both Gate Valves are open and filter is clean Pump Will Not Prime or Function Solution Gate Valves Closed Improper wiring to spa Water level in spa too low Water at Base of the spa Solution Check for condensation from the spa cover Wait to see if moisture dries out Remove Cabinet panel where the power system is loc...
Страница 24: ...hot tub and Avertissement Pour eviter des blessures user de prudence en entrant dans une cuve de relaxation et en sortant Warning Do not use drugs or alcohol before or during the use of a spa or hot tub to avoid unconsciousness and possible drowning and Avertissement Pour eviter l evanouissement et la noyade eventuelle ne prendre ni drogue ni alcool avant d utiliser une cuve de relaxation ni quand...
Страница 25: ...2725 Prairie St SW Wyoming MI 49519 www vikingspas com Email info vikingspas com 2015 Viking Spas Inc ...