manualshive.com logo in svg
background image

8

9

Oven Bake Burner Conversion

Griddle Conversion 

(for models equipped with a griddle)

Adjustment

Screw

Air Shutter

Screw (Front of Burner)

Screw (Rear of Burner)

-Locate bag labeled 050297-000.
-Remove griddle.
-Remove screws securing griddle burner to burner box.
-Loosen air shutter screw and adjust opening on burner to 7/16” and tighten air shutter screw.-
-Use a 1/2” deep socket wrench to remove orifi ce by turning counterclockwise.
-Install orifi ce (#57) from bag labeled 050297-000.

IMPORTANT:

 The orifi ce tip must be located 3/16” inside the burner for proper gas mixture

and combustion. The depth of the orifi ce can be adjusted by turning the orifi ce
counterclockwise (more depth) or clockwise (less depth).

Reverse procedures as needed to reassemble.

36” W. Oven and 48” W. Right Hand Oven Bake Burner

Adjustment

Screw

Air Shutter

Air Shutter

Air Shutter 
Set Screw

Orifice Hood

-Remove oven racks.
-Remove oven bottom.
-Remove scews securing bake burner to oven burner box.
-Loosen air shutter screw and adjust opening on burner to 3/8” (.95 cm) and tighten air shutter screw.
-Remove orifi ce by turning counter-clockwise and replace with orifi ce (#51) from bag labeled 050278-000.

IMPORTANT:

 The orifi ce tip must be located 3/16” inside the burner for proper gas mixture and combustion. The 

depth of the orifi ce can be adjusted by turning the orifi ce counterclockwise (more depth) or clockwise (less depth).

Reverse procedures as needed to reassemble.

48” W. Left Hand Oven Bake Burner

Adjustment

Screw

Air Shutter

-Remove oven racks.
-Remove oven bottom.
-Remove screws securing bake burner to oven burner box.
-Loosen air shutter screw and adjust opening on burner to 3/8” (.95 cm) and tighten air shutter screw.
-Remove orifi ce by turning counter-clockwise and replace with orifi ce (#57) from bag labeled 050297-000.

IMPORTANT:

 The orifi ce tip must be located 3/16” inside the burner for proper gas mixture and combustion. The 

depth of the orifi ce can be adjusted by turning the orifi ce counterclockwise (more depth) or clockwise (less depth).

Reverse procedures as needed to reassemble.

Содержание LPKVGR LP 700 Series

Страница 1: ...issippi 38930 USA 662 455 1200 For product information call 1 888 845 4641 or visit the Viking Web site at vikingrange com in the U S or brigade ca in Canada F21388 EN 053014 Installation Guide LPKVGR LP Conversion Kit for 700 Series Ranges Rangetops ...

Страница 2: ...ution or other acceptable method DO NOT use an open flame to check for leaks CAUTION Be sure the electric power is turned off at the breaker box while the unit is being converted Description Part Number Size Quantity Front Surface Burners In bag 050299 000 55 1 32mm 4 Rear Center Right Rear Surface Burners In bag 050299 000 58 1 07 mm 3 Left Rear Surface Burner In bag 050299 000 67 813mm 1 Main Ov...

Страница 3: ...T The infrared broiler orifice must be changed from rear of range before unit is installed The island trim and rear panel must be removed to access infrared broiler Locate bag labeled 050280 000 Remove nut securing 90 degree fitting and broiler tubing to rear of range Remove orifice from 90º fitting and replace with orifice 56 from the bag labeled 050280 000 Reverse procedure to reassemble Broil N...

Страница 4: ...flange Burner Head Locate bag labeled 050299 000 Remove screws Item 1 with a T 20 Torx bit Remove venturi flange Item 2 Use a metric 10mm nut driver to remove orifice Item 3 Replace left rear orifice with 67 from 050299 000 bag The orifice will have a blue color code ink and 032 stamped on the orifice Replace all other rear orifices with 58 from 050299 000 bag The orifice will have a black color c...

Страница 5: ...curing bake burner to oven burner box Loosen air shutter screw and adjust opening on burner to 3 8 95 cm and tighten air shutter screw Remove orifice by turning counter clockwise and replace with orifice 51 from bag labeled 050278 000 IMPORTANT The orifice tip must be located 3 16 inside the burner for proper gas mixture and combustion The depth of the orifice can be adjusted by turning the orific...

Страница 6: ...version label and place it next to the rating label The rating label is located under the control panel 7KLV DSSOLDQFH ZDV FRQYHUWHG RQ GD PRQWK HDU WR E QDPH DQG DGGUHVV RI RUJDQL DWLRQ PDNLQJ WKH FRQYHUVLRQ ZKLFK DFFHSWV WKH UHVSRQVLELOLW WKDW WKLV FRQYHVLRQ KDV EHHQ SURSHUO PDGH 3 1DW RU 3 JDV ...

Отзывы: