WATER CONNECTION

•Refer to water supply requirement section for preliminary installation and site preparation (see page7 ).
••D

Do

o  n

no

ott  u

usse

e  p

pllaassttiicc  w

waatte

err  lliin

ne

ess  b

be

ettw

we

ee

en

n  rre

effrriig

ge

erraatto

orr  aan

nd

d  ssu

up

pp

pllyy..    P

Pllaassttiicc  w

waatte

err  lliin

ne

ess  ccaan

n  ffaaiill  d

du

ue

e  tto

o  ffaattiig

gu

ue

e  o

ovve

err  ttiim

me

e

aan

nd

d  ccaau

usse

e  e

exxtte

en

nssiivve

e  d

daam

maag

ge

e  tto

o  p

prro

od

du

ucctt  aan

nd

d  tth

he

e  h

ho

om

me

e..

••U

Usse

e  o

on

nllyy  1

1//4

4""  cco

op

pp

pe

err  ttu

ub

biin

ng

g  ffo

orr  w

waatte

err  lliin

ne

e..

•The installation of Viking refrigerator with an reverse osmosis system is acceptable aass  llo

on

ng

g  aass  tth

he

e  w

waatte

err  p

prre

essssu

urre

e

rre

em

maaiin

nss  w

wiitth

hiin

n  tth

he

e  aallllo

ow

waab

blle

e  P

PS

SII  aass  ssttaatte

ed

d  o

on

n  p

paag

ge

e  7

7.. It is important to note that with many reverse osmosis systems,

the pressure starts off high, but then it decreases as the water level of the reverse osmosis storage area drops.  This
must be considered when checking the water pressure coming into the unit.

The 1/4" brass compression union is located in the literature packet.

1.  Pull copper supply tubing from plumbing forward from underneath unit (see Figure A).  
2.  Flush air and impurities from water line by turning on water supply and running two (2) quarts (1.9 L) of water into a

bucket.

3.  Bend the open end of the supply tube to point toward the open end of the Water Valve Tube (see Figure B). Note:

The Water Valve Tube is designed to flex or bend as necessary to line up with the supply tube, so union can be
connected easily.

4.  Remove brass nuts and ferrules from union and slide onto open ends of Water Valve Tube and supply tubing (see

Figure C).

5.  Connect nuts on copper tubing to union (see Figure D). Be sure both nuts are fully seated in union before tightening

nuts. Do Not over tighten.  

6.  Turn on water supply to unit and check for leaks.
7.  Turn off water supply to unit and correct any leaks.  Repeat this process until no leaks exist.
8.  Completely turn on water supply to unit.
9.  Verify drain pan is installed and aligned.  Drain pan must be pushed past and over initial stopping point.

Figure A

Figure B

Copper tubing

Water valve tube

Figure D

Figure C

Brass nuts and
ferrules

Содержание DDBB363

Страница 1: ...allation specifications and dimensions properly install unit remove any moldings or decorative panels that prevent the unit from being serviced make sure that you have these materials not provided wit...

Страница 2: ...er 5 1 cu ft 14 cu meters Total Capacity 20 3 cu ft 57 cu meters Approximate Shipping Weight 500 lbs 227 3 kg BASIC SPECIFICATIONS AND DIMENSIONS DESIGNER MODELS D DE ES SC CR RI IP PT TI IO ON N D DD...

Страница 3: ...Amp Usage 9 9 amps Inlet Water 1 4 copper tubing inlet waterline Requirements minimum 20 psi maximum 120 psi Overall Interior Dimensions Refrigerator 15 2 cu ft 43 cu meters Freezer 5 1 cu ft 14 cu m...

Страница 4: ...ATOR 1 Electronic Controls 2 Spillproof Shelves 5 3 Moisture Control Produce Drawers 2 4 Meat SavorTM Produce Drawer 1 5 Ice Bucket 1 6 Dairy Compartments 2 7 Door Bins 5 8 Wire Freezer Baskets 2 7 7...

Страница 5: ...2 2 9 90 0 2 2 c cm m 2 29 9 7 73 3 7 7 c cm m 7 73 3 3 3 8 8 1 18 86 6 4 4 c cm m 8 82 2 7 7 8 8 2 21 10 0 5 5 c cm m m mi in n a an nt ti i t ti ip p b bo oa ar rd d a an nd d o op pe en ni in ng g...

Страница 6: ...m deep cabinet openings They can be installed in standard 24 61 0 cm deep openings The door faces and top grille will protrude 3 4 1 9 cm into the room 1 1 1 1 2 2 3 3 8 8 c cm m 7 73 3 3 3 8 8 1 18 8...

Страница 7: ...le valve is not used place a separate shut off valve in an easily accessible location between water supply and refrigerator Do not locate shut off valve behind refrigerator The installation of Viking...

Страница 8: ...ance is equipped with a power supply cord having a 3 prong grounding plug To minimize possible shock hazard the cord must be plugged into a mating 3 prong grounding type wall receptacle Do not use an...

Страница 9: ...n n no ot t c co om mp pl le et te el ly y i in ns st ta al ll le ed d K Ke ee ep p d do oo or rs s c cl lo os se ed d u un nt ti il l a ap pp pl li ia an nc ce e i is s c co om mp pl le et te el ly y...

Страница 10: ...10 DOOR SWING CONSIDERATIONS DESIGNER MODEL FULL OVERLAY MODEL...

Страница 11: ...11 TIPPING CONSIDERATIONS PROFESSIONAL MODELS DESIGNER AND FULL OVERLAY MODELS 82 5 8 209 9 cm 86 1 16 218 6 cm...

Страница 12: ...OVERALL DIMENSIONS PROFESSIONAL MODEL S S S S S S 35 1 2 90 2 cm 22 3 16 56 4 cm 24 3 4 62 9 cm 5 16 0 8 cm 9 32 0 7 cm 11 32 0 9 cm D DO OO OR R Side Trim T TO OP P 35 1 2 90 2 cm 35 88 9 cm S SI ID...

Страница 13: ...PROFESSIONAL MODELS Professional models fit semi flush in standard 24 61 0 cm deep cabinet openings The door face protrudes 2 1 2 6 4 cm from the cabinet face The handle protrudes an additional 2 1 2...

Страница 14: ...14 CABINET INFORMATION PROFESSIONAL MODELS Cont d...

Страница 15: ...15 CUSTOM SIDE PANEL DIMENSIONS PROFESSIONAL MODELS FOR 3 4 1 9 cm SIDE PANELS...

Страница 16: ...16 BOTTOM MOUNT REFRIGERATOR OVERALL DIMENSIONS DESIGNER MODELS T TO OP P S SI ID DE E 36 91 5 cm D DO OO OR R F FR RO ON NT T 36 91 5 cm 35 88 9 cm...

Страница 17: ...17 CABINET AND PANEL INFORMATION DESIGNER MODELS Designer models fit flush in standard 24 61 0 cm deep cabinet openings with no protrusion into the room except 2 5 1 cm curved handle depth...

Страница 18: ...ODELS Full overlay models with 3 4 1 9 cm thick panels and custom handles locally supplied fit flush in 25 63 5 cm deep countertop depth cabinet openings with no protrusion into room except custom han...

Страница 19: ...MATION FULL OVERLAY MODELS Full overlay models with 3 4 1 9 cm thick panels and custom handles locally supplied fit flush in 25 63 5 cm deep countertop depth cabinet openings with no protrusion into r...

Страница 20: ...RLAY MODELS Cont d Full overlay models can be installed in standard 24 61 0 cm deep openings However the door faces and top ventilation grille will protrude 3 4 1 9 cm into the room This is ideal for...

Страница 21: ...21 CUSTOM PANEL DIMENSIONS...

Страница 22: ...ns to the right Notch for left hinge door Figure A Front side of 3 4 1 9 cm panel 7 8 2 2 cm 5 8 1 6 cm B Ba ac ck ks si id de e o of f 3 3 4 4 1 1 9 9 c cm m p pa an ne el l w wi it th ho ou ut t t t...

Страница 23: ...ap to door trim and Z brackets 5 Install handle side door trim with screws Install door trim inserts supplied on all four sides of door by starting in one corner and pushing the strip in place 6 Insta...

Страница 24: ...24 Z BRACKET INSTALLATION...

Страница 25: ...t th he e p pr ro od du uc ct t f fo or r e ea ac ch h s si id de e p pa an ne el l u us se ed d N NO OT TE E R Re eq qu ui ir re es s s si id de e p pa an ne el l h ha ar rd dw wa ar re e k ki it t...

Страница 26: ...lication see template in Custom Air Grille Panel Dimensions on pages 31 32 Right hinge application Item Qty Description Size A 2 End 3 x 3 3 4 x 3 4 B 2 Top Bottom See page 28 C 2 Insert End 1 1 2 x 2...

Страница 27: ...NAL CUSTOM AIR GRILLE DUCT LIP EDGE LOCATIONS F FR RO ON NT T V VI IE EW W 35 1 2 90 2 cm 34 86 4 cm 3 4 1 9 cm TYP 1 1 2 3 8 cm 3 7 6 cm 3 3 4 9 5 cm TOP OF CUSTOM AIR GRILLE Bracket Custom Air Grill...

Страница 28: ...cm 3 8 0 95 cm 1 2 1 3 cm 3 4 1 9 cm 3 3 4 9 5 cm TOP VIEW RIGHT VIEW LEFT FRONT VIEW 1 2 1 3 cm 3 4 1 9 cm 3 3 4 9 5 cm 1 8 0 3 cm 3 7 6 cm Bottom View R1 4 Route a 1 2 1 3cm wide by 1 2 1 3 cm deep...

Страница 29: ...29 HINGE COVER DIMENSIONS 1 2 1 3 cm 3 1 8 7 9 cm 1 4 0 6 cm 26o 23 32 1 8 cm Hinge cover protrudes 9 32 0 7 cm beyond wood grille 35 1 2 90 2 cm INSERT DIMENSIONS TOP VIEW FRONT VIEW Right View...

Страница 30: ...unit from skid Use excess packaging to protect decorative trim Verify that leveling legs are up 0 adjustment see Figure 5 6 To avoid floor damage use protective material see Figure 6 U Us se e t tw wo...

Страница 31: ...0 cm beyond rear ledge attach 1 2x4 to wall Item B attach 1 2x4 to rear ledge of cabinet Item C and attach L bracket assembly to 2x4 mounted on wall Item A E El le ec ct tr ri ic ca al l S Sh ho oc ck...

Страница 32: ...unit side N NO OT TE E W Wh he en n m mo ov vi in ng g t th he e u un ni it t i in nt to o p po os si it ti io on n b be e c ca ar re ef fu ul l n no ot t t to o c cr ri im mp p k ki in nk k o or r c...

Страница 33: ...the water level of the reverse osmosis storage area drops This must be considered when checking the water pressure coming into the unit The 1 4 brass compression union is located in the literature pac...

Страница 34: ...with an 8 20 3 cm long magnetic 1 4 6 cm nut driver Pull assembly forward 3 Open refrigerator door so door stop arm and shoulder screw are accessible Shoulder screws should be in 110o door opening pos...

Страница 35: ...is appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle DO NOT CUT OR REMOVE...

Страница 36: ...VIKING RANGE CORPORATION 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 Specifications subject to change without notice F20353 PS0705VR...

Отзывы: