Installation

Any finished flooring should be protected
with appropriate material to avoid damage
from moving the unit.

If unit has been laid on its back or sides,
place unit upright and allow minimum of 24
hours before connecting power.Re-installl
the doors by removing the upper pivot pin
completely, sliding the door onto the lower
pivot pin and re-installing the upper pivot
pin and fastening tightly. Before moving the
unit, make sure the door is secured to the
cabinet (tape may be required to hold the
doors closed).

1. Plug the unit into the 15 amp grounded

outlet located in the installation opening.
With power applied to the unit, check that
the lighting and cooling function operate
properly, then turn off power to the wall
outlet at the circuit breaker.

CAUTION

4. Slide the cabinet into position, making

sure the rear cabinet leveling legs slide
under the anti-tip devices. Push the
cabinet into the opening until the bottom
front edge of the cabinet is flush with the
surrounding cabinetry or the leveling legs
are tight with the anti-tip devices. 

IMPORTANT: The rear cabinet leveling legs
must be engaged under the anti-tip
brackets.

5. Shim the front of the unit so the front face

is flush with surrounding cabinetry. Adjust
the front legs to support the countertop
at the shimmed height. Using an
adjustable wrench or pliers, turn legs
counterclockwise to raise the unit or
clockwise to lower the unit. Countertop
should be resting on top of the unit.

IMPORTANT: If countertop is not resting
entirely on unit top, shim the countertop to
prevent damage to the countertop.

To prevent damage to the countertop and
unit underneath, do not place heavy
objects on countertop directly above the
unit.

CAUTION

Shut off power to the wall outlet before
installing into the opening.

WARNING

2. Check that the following are level and

square:

Front face and interior opening

Installation opening and floor surface

Countertop bottom front edge

IMPORTANT: Leveling legs should not be
extended more than 3/  4” from bottom of
the cabinet.

IMPORTANT: The floor under the unit must
be at the same level as the surrounding
finished floor.

3. If all surfaces are level:

a. Measure from the floor to the bottom 

of the front edge of the countertop

b. Measure the rear of the unit cabinet

from the floor to top of cabinet, at
back corners

c. Adjust rear legs so B measurement

equals A measurement. Using an
adjustable wrench or pliers, turn legs 
counterclockwise to raise the unit or
clockwise to lower the unit

6. Check interior door openings inside the

cabinet to ensure the cabinet is level. Re-
install all shelving and drawers. Take
extreme care to insert sliding shelving
and sliding drawers squarely into slide
brackets and proper slide bracket
grooves. When sliding shelving and
drawers are installed properly a click
should be heard from both slide bracket
retaining clips and should slide smoothly
in the tracks. When sliding shelving or
drawers are pulled out to full extension, a
stop is activated to prevent additional
pull-out.

Improper shelving or drawer installation
may not actuate slide stop mechanism.

CAUTION

Содержание CVBCI5150G

Страница 1: ...tion 15 W 24 W Undercounter Refrigeration VRCI5240G CVRCI5240G VRCO5240D CVRCO5240D VRDI5240D CVRDI5240D VRDO5240D CVRDO5240D VBCI5150G CVBCI5150G VBCI5240G CVBCI5240G VWCI5150G CVWCI5150G VWCI5240G CVWCI5250G ...

Страница 2: ...______________________________________________8 Cutout Dimensions ___________________________________________________________________________8 General Information __________________________________________________________________________9 Anti Tip Brackets____________________________________________________________________________11 Installation ____________________________________________________...

Страница 3: ...ble fluids The fumes can create a fire hazard or explosion Always turn the power on off switch located behind the air grille on top right side to the OFF position before attempting to change light bulbs clean or service the unit FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE THE FUMES CAN CREATE A FIRE HAZARD OR EXP...

Страница 4: ...Contact your municipal waste disposal authority to find out the best and safest way to dispose of your old refrigeration unit Proper Disposal of old refrigeration unit 4 DANGER Altering cutting of the power cord or removal of the power cord removal of power plug or direct wiring can cause serious injury fire and or loss of property and or life and will void the warranty WARNING Never attempt to re...

Страница 5: ... 25 32 40 1 cm min clearance for door swing Power cord 6 5 8 16 8 cm off floor 50 127 0 cm area in which electrical outlet must be located Door Swing 22 1 16 56 0 cm 24 1 16 61 1 cm 27 1 16 68 7 cm 34 1 4 87 0 cm min to 35 89 0 cm max 14 7 8 37 8 cm 14 7 8 37 8 cm 14 7 8 37 8 cm 30 1 8 76 5 cm 5 Dimensions 15 W VBCI CVBCI VWCI CVWCI ...

Страница 6: ...m 7 9 16 12 9 cm 94 0 Swing required for pull out shelf clearance 2 27 32 5 6 cm min clearance from a corner to achieve 94 door swing 24 25 32 40 1 cm min clearance for door swing Power cord 6 7 16 16 8 cm off floor 50 127 0 cm area in which electrical outlet must be located Door Swing Dimensions 24 W VRCI CVRCI VRCO CRVRCO VBCI CVBCI VWCI CVWCI ...

Страница 7: ...0 cm 24 1 16 61 1 cm 27 1 16 68 7 cm 23 7 8 23 7 8 60 6 cm 60 6 cm 23 7 8 60 6 cm 34 1 4 87 0 cm min to 35 89 0 cm max 40 102 0 cm 22 1 16 56 0 cm 24 1 16 61 1 cm 27 1 16 68 5 cm Door Swing Dimensions 24 W VRDI CVRDI VRDO CRVRDO ...

Страница 8: ...6 56 0 cm 24 1 16 61 1 cm 27 1 16 68 7 cm Cutout width 15 38 1 cm 24 61 0 cm Cutout height 34 1 2 87 6 cm min to 35 1 2 90 2 cm max Cutout depth 24 61 0 cm Electrical requirements 115V 60 Hz 15 amp dedicated circuit 5 3 wire cord attached to product Maximum amp usage 3 0 amps Approximate shipping weight 175 lbs 79 0 kg 215 lbs 98 0 kg A 34 1 2 87 6 cm min to 35 1 2 90 2 cm max 24 61 0 cm 4 10 2 cm...

Страница 9: ...stalled Follow the National Electrical Code and local codes and ordinances when installing the receptacle All units come equipped with a NEMA 5 15P 90 plug with a minimum of 5 feet of cord extending beyond the rear of the cabinet The electrical outlet must be flush with or recessed into the back wall IMPORTANT Never use an extension cord to extend the power cord to the electrical receptacle ELECTR...

Страница 10: ...o a hand truck or dolly this should be done with a minimum of two people larger units may require additional help Make sure unit is balanced on transporting device Secure unit to transporting device using soft flexible strapping Protect unit surfaces with cloth material where strapping contacts unit 3 Before moving unit secure door to unit with tape so the door stays closed 4 Carefully move unit t...

Страница 11: ...rackets when properly installed should secure the rear legs and prevent the unit from tipping forward Some installation sites may require modification to provide a secure surface for attaching the brackets Refer to the illustrations below for mounting bracket locations IMPORTANT If installing on a concrete floor concrete fasteners are required and not included with the anti tip kit Anti tip Bracke...

Страница 12: ...p of the unit IMPORTANT If countertop is not resting entirely on unit top shim the countertop to prevent damage to the countertop To prevent damage to the countertop and unit underneath do not place heavy objects on countertop directly above the unit CAUTION Shut off power to the wall outlet before installing into the opening WARNING 2 Check that the following are level and square Front face and i...

Страница 13: ...ecure slotted kickplate by snapping the latch into the latch catch on the unit CAUTION The slotted kickplate must be removable for servicing The floor cannot interfere with removal The slotted sections of the kickplate must not be covered or obstructed so as to prevent proper air circulation ...

Страница 14: ... 1 inch or less from a solid soffit Are all levelers extended down to make contact with the floor Is the unit level Is the power cord connected directly into a properly grounded 3 prong outlet in accordance with all applicable local codes Has all stainless protection film been removed Are the panel s wood overlays if used attached securely and properly Allow the unit to operate for at least 24 hou...

Страница 15: ...e is ever required The model and serial number for your undercounter refrigeration unit are located in the top right under the control housing Model Number ____________________________________Serial Number _______________________ Date of Purchase _______________________________________________________________________ Date Installed __________________________________________________________________...

Страница 16: ...15 Viking Range LLC 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 845 4641 or visit our web site at www vikingrange com in the US or www brigade ca in Canada UL C UL ...

Отзывы: