Electrical Requirements

• Oven requires a separate, grounded 4-wire, 240V (AC), 30 amp (single ovens) and 50 amp (double ovens) service with its own 

circuit breaker.

•  Wire sizes and connections must conform with the rating of the appliance and to the requirements of the National Electrical 

Code, ANSI/NFPA-70 – latest edition, or Canadian Electrical Code, CSA C22.1-1982 and C22.2 No. 01982 – latest edition, and all 
local codes and ordinances.

• Oven must be connected to the proper electrical voltage and frequency as specifi ed on the model/serial rating plate (located 

inside the vent ont the right sode of the oven).

• Oven must be connected to grounded metal permanent wiring system. Check with a qualifi ed electrician to make sure the oven 

is properly grounded.

•  Do not ground to a gas pipe.
•  

Do not

 use an extension cord with this appliance, because this may result in electrical shock or other personal injury.

•  This unit is equipped with a No. 10 ground wire in the conduit.
•  The electrical conduit must be kept to the top left for a fl ush installation. Never cut the conduit.
• Connect the fl exible armored cable directly to 4-wire, 240V household service. If codes permit and separate grounding wiring is 

used, we recommend that a qualifi ed electrician determine the grounding path and that the wire gauge is in accordance with 
local codes.

• Junction boxes installed on rear wall directly behind oven must be recessed.
• A UL-Listed conduit connector must be provided at the junction box.
• 

Do not

 install a fuse in the neutral or grounding circuit. We recommend a time-delayed fuse or circuit breaker. Connect directly to 

the fused disconnect (or circuit breaker box) through fl exible armored, or non-metallic sheathed, copper cable (with grounding 
wire).

Recommendations for Moving

•Only proper equipment should be used to move products.

• ALWAYS

 take steps to protect fl ooring at the installation 

location when moving products.

General Information

WARNING

DO NOT

 use the handle or oven door to lift the oven. 

Remove door before installation to ensure that it is not used 
to lift the unit. See installation section for door removal.  

DO 

NOT

 lift or carry the door by the handle

The oven is heavy—use extreme care when handling.

CAUTION

WARNING

FIRE OR ELECTRICAL SHOCK HAZARD

DO NOT 

use an extension cord with this 

appliance. Such use may result in fi re, electrical 
shock or other personal injury.

•Keep appliance area clear and free from combustible materials, gasoline and other fl ammable vapors.
•Disconnect the electrical supply prior to servicing or cleaning.
• When removing the appliance for cleaning or service, disconnect AC power supply and carefully remove the appliance by pulling 

forward.

•Electrical requirements are listed in the product specifi cations under the electrical requirements section.

Recommendations for Unpacking

•Products are shipped on pallets with foam footings and corrugated inner-packing and exterior hoods.
•Products are anchored to the pallet using metal straps that are screwed to the bottom of the product and the pallet.

DO NOT

 remove protective packaging until you are ready to perform the installation.

•To remove the packaging, fi rst remove the staples located at the bottom perimeter of the corrugated cover.
•Remove the corrugated cover by lifting it off  the product and remove the inner-packing.
•Detach the product from the metal anchor strip by removing the attachment screw.

DO NOT

 remove the protective wrapping from the product control panel until the product is installed.

•All openings in the wall behind the appliance or in the fl oor under the appliance should be sealed.

Содержание CMVDOE630

Страница 1: ...1 Installation GUIDE 6 SERIES Built in Electric Single and Double Wall Ovens MVSOE630 CMVSOE630 MVDOE630 CMVDOE630...

Страница 2: ...____________________________________ 14 Before beginning installation read these instructions thoroughly and carefully DO NOT remove permanently affixed labels warnings or plates from the product as t...

Страница 3: ...or cabinet supplier to make sure that the materials meet these requirements CAUTION This appliance is not to be used by persons including children with reduced physical sensory or mental capabilities...

Страница 4: ...4 Dimensions 30 Single Oven 30 Double Oven 24 61 cm 29 3 8 74 6 cm 29 3 4 75 6 cm 24 61 cm 29 3 4 75 6 cm 51 3 8 130 5 cm...

Страница 5: ...cm 51 1 2 130 8 cm Cutout depth Standard Install Flush Mount 24 61 0 cm Electrical requirement 4 wire ground 240 VAC 30 amp electrical connection for single ovens 50 amp for double ovens Unit is equip...

Страница 6: ...12 7 cm Junction box location 4 3 4 12 1 cm min to floor 30 72 4 cm 28 1 4 71 8 cm 24 61 0 cm 28 1 2 72 4 cm 50 5 8 128 5 cm Flush mount 51 1 2 130 8 cm 15 1 4 38 7 cm min to floor 4 10 2 cm 5 min 12...

Страница 7: ...2 cm 15 1 4 min 38 7 cm to the floor Finished Surfaces 3 4 1 9 cm Vertical Blocking on both sides 29 1 2 74 9 cm 24 61 0 cm 30 76 2 cm 5 min 12 7 cm Junction box location 4 10 2 cm 4 3 4 min 12 1 cm...

Страница 8: ...m 15 1 4 min 38 7 cm to the floor Finished Surfaces 3 4 1 9 cm Vertical Blocking on both sides 29 1 2 74 9 cm 24 61 0 cm 30 76 2 cm 5 min 12 7 cm Junction box location 4 10 2 cm 4 3 4 min 12 1 cm to t...

Страница 9: ...thed copper cable with grounding wire Recommendations for Moving Only proper equipment should be used to move products ALWAYS take steps to protect flooring at the installation location when moving pr...

Страница 10: ...his appliance BE SURE that support for this appliance is perpendicular to the front facing of the wall or cabinet before you perform the installation Use of a hydraulic lift is recommended for the ins...

Страница 11: ...tion 1 connect the white and green to the incoming neutral Wiring option 2 connect the white to the incoming neutral attach green to grounded junction box Wiring option 3 connect the white to the inco...

Страница 12: ...in Attach screws to the side of the framing Note Two screws for single ovens four screws for double ovens screws not included 11 12 1 13 2 14 Replace racks Replace door Open door completely Rotate do...

Страница 13: ...water are rarely needed Final Preparation Performance Checklist A qualified installer should carry out the following checks Check oven Bake Function bake element on full power center and outside broil...

Страница 14: ...f you continue to have service problems contact Viking Range LLC at 1 888 845 4641 or write to VIKING RANGE LLC PREFERRED SERVICE 111 Front Street Greenwood Mississippi 38930 USA Record the following...

Страница 15: ..._________________________ Date of purchase ______________________________________________________________________ Date installed _______________________________________________________________________...

Страница 16: ...A EN Viking Range LLC 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 845 4641 or visit our web site at vikingrange com in the US or brigade ca in Cana...

Отзывы: