8
|
SIDE BURNER ACCESSORY CARE & USE/INSTALLATION
BUILT-IN INSTALLATIONS
Built-in accessories are intended for installation in a built-in
enclosure constructed of non-combustible materials.
The accessory drops into the opening shown in the cutout
detail drawing and hangs from its counter-top trim. A deck
is not required to support it from the bottom.
Pay special attention to the provisions shown for gas line
hook-up. (See INDEX: “Cut-out Dimensions for Built-in Grills
& Accessories”)
Installation provisions may be made for the power burner
installation. The power burner cooking height may be
reduced to better accommodate large cooking pots.
Clearances to combustible material must be maintained
as outlined below. No combustible material shall be used
in the construction of a counter top using a recessed
application.
The enclosure should have ventilation holes to prevent
gas build-up in the event of a leak. The counter should be
flat and level. (Refer to ANSI Z21.58 Standard for Outdoor
Cooking Gas Appliances, Section 1.7 Enclosures For Self
Contained LP-Gas Supply Systems or local codes for
additional information.)
The grill accessory may be powered from either a 120 volt,
60 hertz, 15 amp GFI certified outlet installed by a qualified
electrician OR it may be powered directly from your grill
transformer power supply.
When a grill is not available or if the grill is not located close
enough to the accessory a LASK (Accessory Switch Kit) is
available as an optional purchase.
CLEARANCE TO COMBUSTIBLE MATERIALS
Minimum clearance from the sides and back of the
accessory to adjacent combustible construction below the
counter top is 12” from the sides and back.
Dégagement minimal entre les parois latérales et l’arrière
de l’appariel et la construction combustible au-dessous
du panneau supérieur de l’appareil (30 cm à partir des
parois latérales et 30 cm à partir de l’arrière).
Minimum clearance from sides and back of unit to adjacent
combustible construction extending above the counter top
is 18” from the sides and back.
Dégagement horizontal minimal entre les parois latérales
et l’arrière de l’appariel et la construction verticale
combustible au-dessus de l’appareil (45.7 cm à partir des
parois latérales et 45.7 cm à partir de l’arrière).
Do not use this appliance under unprotected overhead
combustible surfaces.
Ne pas utiliser cet appareil sous une surface combustible.