Viking ElectronicsElectronics K-1270 Series Скачать руководство пользователя страница 10

10

This timer sets the maximum amount of time the 

K-1270

 will look for the call to be answered. If this timer expires 

and the tenant has not answered, the call will be terminated or the 

K-1270

 will dial a second phone number (if 

programmed). The factory setting is 20 seconds, and to disable this feature, enter “

00

” into position 43.

J.  Maximum Ring Time

This time out is started once the call has been connected and is reset every time audio is detected on the phone 
line. If it expires, the call will be terminated. This is useful on systems that are silent when the tenant hangs up to 
assure the 

K-1270

 disconnects. It is factory set to 10 seconds and can be disabled by entering “

00

” in position 

44.

K.  Silence Time Out

This time represents the amount of time the 

K-1270

 will delay before switching back to the microphone mode 

after it was in the speaker mode (VOX switching time). It is in 100 msec increments and stored in position 45.

L.  Talk/Listen Delay

On some phone lines, a faster rate of dialing is allowed. The dialing speed of the 

K-1270

 can be altered to take 

advantage of this faster rate. The normal dialing speed is 5 digits per second and is selected by entering “

#30

” 

(factory setting) while in programming. To increase the speed to 10 digits per second, enter “

#31

”. If the faster 

rate is selected, be sure to test each number to assure proper operation.

M.  Dialing Speed

The 

K-1270

 is factory set to hang up if continuous audio is detected after dialing. In most situations this would 

happen if the tenant hung up and the service that the 

K-1270

 is connected to provides a dial tone following the 

hang up. In some instances due to noisy lines or loud background noise, the call may be terminated before the 
tenant hangs up. If this occurs, enter “

#33

” when in programming. This will disable return to dial tone feature and 

stop the 

K-1270

 from hanging up prematurely. To enable this feature enter “

#32

” when in programming.

N.  Hang Up on Return to Dial Tone

See Operation for a functional description of this feature.  Tenant Initiated Entry is disabled by default.  To enable 
it, enter programming (see 

Programming

 section 

A

).  Enter

 #38

.  Also, DIP switch 1 must be turned ON and left 

in this position to enable the 

K-1270

 to answer incoming calls.  To disable Tenant Initiated Entry, enter 

#37

Security considerations with Tenant Initiated Entry:

 The 

K-1270

 door entry system is designed with security 

in mind, which is the reason an access code is recommended in cases where Tenant Initiated Entry is allowed.  
To understand the need for an access code, consider the following example.  A person walks up to the entry and 
pushes one of the directory buttons on the 

K-1270

.  The unit looks up the number associated with that directory 

position and dials it.  The phone inside the tenant’s apartment rings, and is answered by someone who happens 
to be a guest in the tenant’s apartment.  The guest notices that the tenant’s phone is displaying the caller ID of 
the number that just called, which is the number of the 

K-1270

.  They jot the number down.  The guest can now 

call the 

K-1270

 at a later time, if DIP switch 1 is on, Tenant Initiated Entry is allowed, the access code is disabled, 

and they know the door strike code, they can let themselves into the building.  Note that by default, Tenant Initiated 
Entry is not allowed, but if this feature is allowed, it is important to program an access code (see 

C.  Access Code 

(

memory location #48

).

 

O.  Tenant Initiated Entry

To clear all speed dial positions and set all modes back to factory setting, enter “

###

“ while in programming. 

Caution

, all previous programming will be lost

. Normally when the 

K-1270

 is in the programming mode, it will 

hang up the line if no commands are detected for 20 seconds. To hang up immediately, enter “

##7

”.

P.  Special Commands

In  some  installations,  it  maybe  desirable  to  limit  the  length  of  the  call  to  the  tenant.  This  can  be  done  by 
programming  position 

#42

. The  maximum  call  time  can  be  set  from  1  minute  to  9  minutes  by  entering  the 

appropriate number in position 

#42

.  A “

0

” will yield a 30 second time. To disable the call timer enter “

#42

” without 

any preceding digit.

I.   Maximum Call Time

Содержание K-1270 Series

Страница 1: ...Mylar speaker Self draining mic mount Faceplate keypad mic and speaker gaskets Designed to meet IP66 Ingress Protection Rating see DOD 859 Operates on 12 to 24 volts AC DC 12 speed dial buttons 22 digits each 12 alternate number positions 22 digits each One button operation no call button Hang up on CPC busy silence time out or dial tone Touch tone restriction from microphone Integral relays for c...

Страница 2: ...c Die cast with Satin Chrome Finish internally sealed per IP67 Speaker Screen Speaker screen with 0 018 wide slots to prevent punctures from paperclips etc Faceplate Material 14 gauge 316 stainless steel with 4 brushed finish Speaker Mylar speaker with rubber gasket to maintain water tight seal and eliminate water deterioration Blue Call LED Lights steady to help locate the button in low light Mic...

Страница 3: ...urface mount unit using an optional VE 5x10 The rough in box uses the inner set of four holes on the face plate while the VE 5x10 uses the outside set of holes A set of dummy screws and nuts are provided to fill the unused mounting holes To install a directory remove the four screws that mount the directory lens to the front of the K 1270 using the included Allen wrench Insert a paper directory be...

Страница 4: ... more information VIKING VIKING ELECTRONICS HUDSON WI 54016 STAND ALONE DOOR CONTROLLER ENTRY SYSTEM POWER 12V DC MODEL ES 1 1 POWER PROGRAM PHONE LOG BUS 2 3 4 5 GANG PROG 6 7 8 9 WIEGAND DEVICE 10 11 DOOR STRIKE N O 2 1 L H COM N C BLK RED GRN WHT Doorstrike 12V DC Adapter included with ES 1 OR Share power with 12 24V AC DC door strike with 200mA available current or use the included 12V DC adap...

Страница 5: ... door strike will energize for the programmed Door Strike Time Note To prevent unwanted radio interference route the connecting wires through the included ferrite core Note The gel filled water tight butt connectors are designed for insulation displacement on 19 26 gauge wire with a maximum insulation of 0 082 inches Cut off stripped ends prior to terminating Rear View of the K 1270 CO Line Yellow...

Страница 6: ...el C 1000B not included Doorstrike Magnetic Lock 120V AC 120V AC 120V AC D Using the K 1270 with a C 3000 For a No CO installation a Viking C 3000 No CO controller can be used with the K 1270 Note the K 1270 will need to be programmed on a separate CO line or use the Viking DLE 200B The door strike can be controlled by the K 1270 or the internal relay on the C 3000 just be sure to disable the door...

Страница 7: ... DC maximum not included Doorstrike Power Supply Doorstrike 1 5A 30V DC maximum not included Doorstrike Power Supply Doorstrike 2 5A 30V DC maximum not included Doorstrike Power Supply Doorstrike 3 5A 30V DC maximum not included Doorstrike Power Supply Doorstrike 4 Entry Point 3 K 1275 K 1275 E Add Relay Control for up to 4 K 1270 75 Proximity Card Readers IMPORTANT Electronic devices are suscepti...

Страница 8: ...ing programming If this happens check to see that DIP switch 1 is ON so the unit is set to answer incoming calls Then turn DIP switch 4 ON to allow accessing programming without the security code Call the line attached to the K 1270 With the phone ringing press the 0 button on the K 1270 keypad The K 1270 should answer the line and you should hear two beeps indicating that you are in the programmi...

Страница 9: ...p to twelve 46 digit numbers Each number can also be programmed with special features such as pauses and the Touch Tones Q and Each of the special characters count as a single digit Each of the speed dial positions 01 to 12 pertain to the corresponding button on the front of the K 1270 The button 0 uses position 10 the Q uses position 11 and the uses position 12 To program a speed dial position en...

Страница 10: ...eration for a functional description of this feature Tenant Initiated Entry is disabled by default To enable it enter programming see Programming section A Enter 38 Also DIP switch 1 must be turned ON and left in this position to enable the K 1270 to answer incoming calls To disable Tenant Initiated Entry enter 37 Security considerations with Tenant Initiated Entry The K 1270 door entry system is ...

Страница 11: ...ess code following the single beep hear two acknowledgement beeps and then either let the visitor in using the doorstrike code or hang up to terminate the call A double beep after the unit answers indicates both that Tenant Initiated Entry is enabled and that the access code is disabled so the user can let the visitor in using the doorstrike code without having to enter the access code or terminat...

Страница 12: ...stance Monday 8am 4pm and Tuesday through Friday 8am 5pm central time So that we can give you better service before you call please 1 Know the model number the serial number and what software version you have see serial label 2 Have your Product manual in front of you 3 It is best if you are on site RETURNING PRODUCT FOR REPAIR The following procedure is for equipment that needs repair 1 Customer ...