4.0 Features Overview

Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or subsidiaries
assume no responsibility for errors and omissions contained in this information. Revisions of this document or new editions of it may be issued to incorporate such changes.

See the Product Manual for complete installation and programming instructions.

Questions? Call Viking Product Support:  715-386-8666

K-1270-IP Quick Start Guide

ZF303875 REV A

•  Make sure the port is not in trunk mode
•  Make sure port is capable of 100mbps full duplex
•  Disable Spanning Tree Protocol (STP) or enable Portfast

3.0 Network Port Settings

MAC:

18E80FXXXXXX

asdesaxtff

N.C.

 - Black

+ Red

 Green

 Green

N.O.

COM.

N.C. (Gray)

N.O. (Yellow)

COM. (Blue)

 Relay 1 Output Contacts

(2A@30VDC/ 250VAC max)

 Relay  2 Output Contacts

(2A@30VDC/ 250VAC max)

 Request for Exit 

(REX) Input

3 Gel-Filled Butt

Connectors 

(included)

+ Red

- Black

Black

Black

- Black

+ Red

Speaker

LED

Microphone

Call Switch

MAC Address Label: 

The 

MAC address is aunique 
12 digit number used by 
routers to send network 
traffic to the correct IP 
address.

PoE LAN Port 10/100, 
PoE Class 2 (<6.5 Watts): 

Connect to your LAN via 
RJ45 plug and CAT5 or 
greater twisted pair wire.

Yellow Network Status 
LED: 

Lights steady to 

indicate power and data 
link. Blinks to indicate 
network activity.

Green Unit Status LED

Rear (PCB) View of K-1270-IP

White

White

(Power typically not

required for gate controllers)

Doorstrike / 
Magnetic Lock

120V AC

Connect to Optional 

Doorstrike, Mag Lock, 

Gate Controller, etc.

(not

connected)

12 VDC Power Output for 

VE-LIGHT, etc. 

(12VDC @ 50mA max)

  

Brown

Violet

White

 - Black

+ Red

 Green

 White

Proximity Card 

Reader (26 Bit 

Wiegand Input)

Optional: Connect to an additional 
Long Range RFID Receiver with 26 
Bit Wiegand Output  (Viking Model 
PRX-3  or LRR-4 See DOD# 228 
OR 226)

 Optional 

Long Range 

RFID Receiver 

Note:  

The gel-filled (water-tight) butt connectors are designed for insulation displacement on 19-26 gauge wire with a

maximum insulation of 0.082 inches. Cut off stripped wire ends before terminating.

2.0 Power Source

Select 

PoE Switch 

or 

PoE Injector 

that meets the following requirements:

1.  IEEE 802.3af / 802.3at / 802.3bt compliant 
2.  Capable of providing at least 4 Watts (class 1)

Note: 

CAT5e (or higher) cable recommended

Отзывы: