VIKING TECHNICAL SUPPORT 1.800.908.0884
1 0
SPECIFICATIONS
SPECIFICATIONS
Max Gate Length
14 Feet
Max Gate Weight
600 lbs
UL 325 Classification
Class I, II, III, IV *refer to page 5
Duty Cycle
100%
Operating Voltage
24VDC
Main Power Source
120VAC / 240VAC Single Phase
Main Power Current
1.5A / 1.0A (each motor)
Main Power Frequency
50Hz / 60Hz
Main Power Fuse
4.0A Timed
Alternative Power
24VAC / VDC (60VA) or Solar
Accessory Power
24VDC (750mA)
Power Consumption - Sleep
28mA
Motor Current Draw - Typical
2.0A
Operating Temperature
-20°F (-28°C) to 131°F (55°C)
Opening Angle
120°
!
IMPORTANT:
Cable shall be shielded with drain wire.
Connect drain wire to chassis ground of both the Operator
and the ECU.
MOTOR CABLE LENGTH/GAUGE
40 Feet
16 AWG
60 Feet
14 AWG
80 Feet
12 AWG
120 Feet
10 AWG
More than 120 Feet
Not Recommended
5½
4
⅜
14
⅜
15¾
1¾
1
⅛
13
2
⅜
9
⅞
4
Ø
⅜
2
⅜
16
⅛
5
⅛
5
⅛
0
2
6
12
18
0
1
2¼
4
5¾
8
⅛
0
4
⅜
5
⅞
12
⅞
14
⅜
18
¾
0
18
⅛
7½
15¾
Front
Bottom
15
½
Large ECU
(OPTIONAL)
Part# VA-ECUBBB
0
2
6
10
14
16
0
1½
4½
6
⅛
0
3
⅜
4
⅞
11
⅞
13
⅜
16
¾
0
5¼
13½
15
⅝
Front
Bottom
Standard ECU